Modelling alternating current effects in a submerged arc furnace

被引:1
作者
Luckins, Ellen K. [1 ]
Oliver, James M. [1 ]
Please, Colin P. [1 ]
Sloman, Benjamin M. [2 ]
Valderhaug, Aasgeir M. [2 ]
Van Gorder, Robert A. [3 ]
机构
[1] Univ Oxford, Math Inst, Andrew Wiles Bldg,Woodstock Rd, Oxford OX2 6GG, England
[2] Elkem ASA, Technol, Fiskaaveien 100, N-4621 Kristiansand, Norway
[3] Univ Otago, Dept Math & Stat, POB 56, Dunedin 9054, New Zealand
基金
英国工程与自然科学研究理事会;
关键词
submerged arc furnace; equivalent circuit model; heat transfer; electric arc; periodic solutions of non-linear systems; non-linear dynamics;
D O I
10.1093/imamat/hxac012
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
Modelling the production of silicon in a submerged arc furnace (SAF) requires accounting for the wide range of timescales of the different physical and chemical processes: the electric current which is used to heat the furnace varies over a timescale of around 10(-2) s, whereas the flow and chemical consumption of the raw materials in the furnace occurs over several hours. Models for the silicon furnace generally either include only the fast-timescale, or only the slow-timescale processes. In a prior work, we developed a model incorporating effects on both the fast and slow timescales, and used a multiple-timescales analysis to homogenise the fast variations, deriving an averaged model for the slow evolution of the raw materials. For simplicity, in the previous work we focussed on the electrical behaviour around the base of a single electrode, and prescribed the current in this electrode to be sinusoidal, with given amplitude. In this paper, we extend our previous analysis to include the full electrical system, modelled using an equivalent circuit system. In this way, we demonstrate how the two furnace-modelling approaches (on the fast and slow timescales) may be combined in a computationally efficient way. Our previously derived model for the arc resistance is based on the assumption that the dominant heat loss from the arc is by radiation (we will refer to this as the radiation model). Alternative arc models include the empirical Cassie and Mayr models, which are commonly used in the SAF literature. We compare these various arc models, explore the dependence of the solution of our model on the model parameters and compare our solutions with measurements from an operational silicon furnace. In particular, we show that only the radiation arc model has a rising current-voltage characteristic at high currents. Simulations of the model show that there is an upper limit on the length of the furnace arc, above which all the current bypasses the arc and flows through the surrounding material.
引用
收藏
页码:492 / 520
页数:29
相关论文
共 22 条
  • [1] Andresen, 1995, THESIS NTH NORWAY
  • [2] Awagan G.R, 2016, INT J SCI ENG RES, V7, P684
  • [3] Barker I.J., 2007, 11 INT FERROALLOYS C
  • [4] Bhonsle Deepak C., 2014, Journal of Electrical Engineering, V14, P1
  • [5] Bowman Ben., 2009, Arc furnace physics
  • [6] Cassie A. M., 1939, Tech. Rep. 102
  • [7] Generalised Cassie-Mayr electric arc furnace models
    Golestani, Samaneh
    Samet, Haidar
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (13) : 3364 - 3373
  • [8] Gustavsson N., 2004, LITHISYEX34922004
  • [9] Hannesson T.H., 2016, SI PROCESS DRAWINGS
  • [10] Mathematical Modeling and Experimental Validation of an Electric Arc Furnace
    Logar, Vito
    Dovzan, Dejan
    Skrjanc, Igor
    [J]. ISIJ INTERNATIONAL, 2011, 51 (03) : 382 - 391