Spatial Precision in Magnetic Resonance Imaging-Guided Radiation Therapy: The Role of Geometric Distortion

被引:123
作者
Weygand, Joseph [1 ,2 ]
Fuller, Clifton David [2 ,3 ]
Ibbott, Geoffrey S. [1 ,2 ]
Mohamed, Abdallah S. R. [3 ,5 ]
Ding, Yao [3 ]
Yang, Jinzhong [1 ,2 ]
Hwang, Ken-Pin [4 ]
Wang, Jihong [1 ,2 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas Houston, Grad Sch Biomed Sci Houston, Houston, TX USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[5] Univ Alexandria, Dept Clin Oncol & Nucl Med, Alexandria, Egypt
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2016年 / 95卷 / 04期
关键词
GRADIENT COIL DESIGN; LEKSELL STEREOTACTIC SYSTEM; MR-LINAC DESIGN; FIELD-OF-VIEW; CHEMICAL-SHIFT; PROSTATE-CANCER; SUSCEPTIBILITY ARTIFACTS; T MRI; LARGE NONUNIFORMITIES; NUMERICAL-ANALYSIS;
D O I
10.1016/j.ijrobp.2016.02.059
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Because magnetic resonance imaging-guided radiation therapy (MRIgRT) offers exquisite soft tissue contrast and the ability to image tissues in arbitrary planes, the interest in this technology has increased dramatically in recent years. However, intrinsic geometric distortion stemming from both the system hardware and the magnetic properties of the patient affects MR images and compromises the spatial integrity of MRI-based radiation treatment planning, given that for real-time MRIgRT, precision within 2 mm is desired. In this article, we discuss the causes of geometric distortion, describe some well-known distortion correction algorithms, and review geometric distortion measurements from 12 studies, while taking into account relevant imaging parameters. Eleven of the studies reported phantom measurements quantifying system-dependent geometric distortion, while 2 studies reported simulation data quantifying magnetic susceptibility-induced geometric distortion. Of the 11 studies investigating system-dependent geometric distortion, 5 reported maximum measurements less than 2 mm. The simulation studies demonstrated that magnetic susceptibility-induced distortion is typically smaller than system-dependent distortion but still nonnegligible, with maximum distortion ranging from 2.1 to 2.6 mm at a field strength of 1.5 T. As expected, anatomic landmarks containing interfaces between air and soft tissue had the largest distortions. The evidence indicates that geometric distortion reduces the spatial integrity of MRI-based radiation treatment planning and likely diminishes the efficacy of MRIgRT. Better phantom measurement techniques and more effective distortion correction algorithms are needed to achieve the desired spatial precision. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1304 / 1316
页数:13
相关论文
共 122 条
[1]  
Afzali M, 2011, MACHINE VISION IMAGE, V7, P1
[2]  
Archip N, 2008, NEUROSURGERY, V63, P209, DOI [10.1227/01.NEU.0000297081.51540.45, 10.1227/01.neu.0000317395.08466.e6]
[3]   EDGE ARTIFACTS IN MR IMAGES - CHEMICAL-SHIFT EFFECT [J].
BABCOCK, EE ;
BRATEMAN, L ;
WEINREB, JC ;
HORNER, SD ;
NUNNALLY, RL .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (02) :252-257
[4]   ANALYSIS OF MACHINE-DEPENDENT AND OBJECT-INDUCED GEOMETRIC DISTORTION IN 2DFT MR IMAGING [J].
BAKKER, CJG ;
MOERLAND, MA ;
BHAGWANDIEN, R ;
BEERSMA, R .
MAGNETIC RESONANCE IMAGING, 1992, 10 (04) :597-608
[5]   Characterization, prediction, and correction of geometric distortion in 3 T MR images [J].
Baldwin, Lesley N. ;
Wachowicz, Keith ;
Thomas, Steven D. ;
Rivest, Ryan ;
Fallone, B. Gino .
MEDICAL PHYSICS, 2007, 34 (02) :388-399
[6]   A two-step scheme for distortion rectification of magnetic resonance images [J].
Baldwin, Lesley N. ;
Wachowicz, Keith ;
Fallone, B. Gino .
MEDICAL PHYSICS, 2009, 36 (09) :3917-3926
[7]   MAGNETIC-FIELD GRADIENT COILS FOR NMR IMAGING [J].
BANGERT, V ;
MANSFIELD, P .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1982, 15 (02) :235-239
[8]   MR ARTIFACTS - A REVIEW [J].
BELLON, EM ;
HAACKE, EM ;
COLEMAN, PE ;
SACCO, DC ;
STEIGER, DA ;
GANGAROSA, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (06) :1271-1281
[9]   NUMERICAL-ANALYSIS OF THE MAGNETIC-FIELD FOR ARBITRARY MAGNETIC-SUSCEPTIBILITY DISTRIBUTIONS IN 3D [J].
BHAGWANDIEN, R ;
MOERLAND, MA ;
BAKKER, CJG ;
BEERSMA, R ;
LAGENDIJK, JJW .
MAGNETIC RESONANCE IMAGING, 1994, 12 (01) :101-107
[10]   NUMERICAL-ANALYSIS OF THE MAGNETIC-FIELD FOR ARBITRARY MAGNETIC-SUSCEPTIBILITY DISTRIBUTIONS IN 2D [J].
BHAGWANDIEN, R ;
VANEE, R ;
BEERSMA, R ;
BAKKER, CJG ;
MOERLAND, MA ;
LAGENDIJK, JJW .
MAGNETIC RESONANCE IMAGING, 1992, 10 (02) :299-313