Visualization of Underfill Flow in Ball Grid Array (BGA) using Particle Image Velocimetry (PIV)

被引:0
作者
Ng, Fei Chong [1 ]
Abas, Aizat [1 ]
Abustan, Ismail [2 ]
Rozainy, Z. Mohd Remy [2 ]
Abdullah, M. Z. [2 ]
Jamaludin, Ali B. [3 ]
Kon, Sharon Melissa [1 ]
机构
[1] Univ Sains Malaysia, Sch Mech Engn, Engn Campus, Nibong Tebal 14300, Penang, Malaysia
[2] Univ Sains Malaysia, Sch Civil Engn, Engn Campus, Nibong Tebal 14300, Penang, Malaysia
[3] TNB Res Sdn Bhd, Kawasan Inst Penyelidikan, 1 Lorong Ayer Itam, Kajang 43000, Malaysia
来源
INTERNATIONAL CONFERENCE ON AEROSPACE AND MECHANICAL ENGINEERING (AEROMECH17) | 2018年 / 370卷
关键词
ENCAPSULATION;
D O I
10.1088/1757-899X/370/1/012064
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
This paper presents the experimental methodology using particle image velocimetry (PIV) to study the underfill process of ball grid array (BGA) chip package. PIV is a non-intrusive approach to visualize the flow behavior of underfill across the solder ball array. The BGA model of three different configurations - perimeter, middle empty and full array - were studied in current research. Through PIV experimental works, the underfill velocity distribution and vector fields for each BGA models were successfully obtained. It is found that perimeter has the shortest filling time resulting to a higher underfill velocity. Therefore, it is concluded that the flow behavior of underfill in BGA can be justified thoroughly with the aid of PIV.
引用
收藏
页数:6
相关论文
共 11 条
  • [1] Effect of ILU dispensing types for different solder bump arrangements on CUF encapsulation process
    Abas, Aizat
    Haslinda, M. S.
    Ishak, M. H. H.
    Nurfatin, A. S.
    Abdullah, M. Z.
    Ani, F. Che
    [J]. MICROELECTRONIC ENGINEERING, 2016, 163 : 83 - 97
  • [2] Ardebili H, 2009, MATER PR ELECT APPL, P129
  • [3] Champagnat F., 2009, PRINCIPLES APPL PART
  • [4] Ishak M. H. H., 2015, MICROELECTRONICS REL
  • [5] FVM based numerical study on the effect of solder bump arrangement on capillary driven flip chip underfill process
    Khor, C. Y.
    Abdullah, M. Z.
    Mujeebu, M. Abdul
    Ani, F. Che
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (03) : 281 - 286
  • [6] Khor C. Y., J ELECT PACKAGING, V134, P11003
  • [7] Effect of different stent configurations using Lattice Boltzmann method and particles image velocimetry on artery bifurcation aneurysm problem
    Mokhtar, N. Hafizah
    Abas, Aizat
    Razak, N. A.
    Hamid, Muhammad Najib Abdul
    Teong, Soon Lay
    [J]. JOURNAL OF THEORETICAL BIOLOGY, 2017, 433 : 73 - 84
  • [8] Effect of thermocapillary action in the underfill encapsulation of multi-stack ball grid array
    Ng, Fei Chong
    Abas, Aizat
    Ishak, M. H. H.
    Abdullah, M. Z.
    Aziz, Abdul
    [J]. MICROELECTRONICS RELIABILITY, 2016, 66 : 143 - 160
  • [9] Seok Hwan Lee, 2010, MICROELECTRON RELIAB, V50, P12
  • [10] Sung Jaeyong, 2011, J VISUAL-JAPAN, V14, P237