Mass spectrometric top-down analysis of proteins

被引:19
作者
Macht, Marcus [1 ]
机构
[1] Bruker Daltonik GmbH, D-28359 Bremen, Germany
关键词
ELECTRON-CAPTURE DISSOCIATION; ION-CYCLOTRON RESONANCE; COLLISION-INDUCED DISSOCIATION; IN-SOURCE DECAY; ASSISTED-LASER-DESORPTION/IONIZATION; MULTIPLY-CHARGED IONS; INFRARED MULTIPHOTON DISSOCIATION; NONENZYMATICALLY GLYCATED PEPTIDES; AMINO-ACID-SEQUENCE; OF-FLIGHT;
D O I
10.4155/BIO.09.93
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The comprehensive analysis of intact proteins down to the level of their individual amino acid sequence and the entirety of post-translational modifications is an area that can hardly be covered by the typical workflow in MS based protein analysis, which comprises enzymatic digestion, mass spectrometric analysis and subsequent database search. This approach typically provides 20-80% sequence coverage, which is not sufficient for the characterization of biopharmaceuticals, for example. This generates the requirement for a comprehensive analysis of the protein, without the risk of losing sequence information due to undetected peptides. Top-down sequencing of proteins starts from the intact protein, typically by determining the intact protein mass in the first step, a fragmentation of the intact protein is then performed within the mass spectrometer, resulting in fragment ions that allow us to pinpoint the protein sequence, as well as potential modifications or mutations in their localization and structure. A number of technologies have been developed for this task in the last few years, based on various different mass spectrometric instrument configurations, but typically based on the same technology platforms as used for bottom-up strategies. Thus, the use of one specific instrument often allows the application of top-down and bottom-up technologies in a complementary way, providing much more detailed information about the proteins of interest than either of the approaches alone.
引用
收藏
页码:1131 / 1148
页数:18
相关论文
共 154 条
[61]   LASER DESORPTION IONIZATION OF PROTEINS WITH MOLECULAR MASSES EXCEEDING 10000 DALTONS [J].
KARAS, M ;
HILLENKAMP, F .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2299-2301
[62]   Applications of in-source fragmentation of protein ions for direct sequence analysis by delayed extraction MALDI-TOF mass spectrometry [J].
Katta, V ;
Chow, DT ;
Rohde, MF .
ANALYTICAL CHEMISTRY, 1998, 70 (20) :4410-4416
[63]   USE OF A SINGLE-QUADRUPOLE MASS-SPECTROMETER FOR COLLISION-INDUCED DISSOCIATION STUDIES OF MULTIPLY CHARGED PEPTIDE IONS PRODUCED BY ELECTROSPRAY IONIZATION [J].
KATTA, V ;
CHOWDHURY, SK ;
CHAIT, BT .
ANALYTICAL CHEMISTRY, 1991, 63 (02) :174-178
[64]   Top-down proteomics [J].
Kelleher, NL .
ANALYTICAL CHEMISTRY, 2004, 76 (11) :196A-203A
[65]   Top down versus bottom up protein characterization by tandem high-resolution mass spectrometry [J].
Kelleher, NL ;
Lin, HY ;
Valaskovic, GA ;
Aaserud, DJ ;
Fridriksson, EK ;
McLafferty, FW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1999, 121 (04) :806-812
[66]   Peptide sequencing and characterization of post-translational modifications by enhanced ion-charging and liquid chromatography electron-transfer dissociation tandem mass spectrometry [J].
Kjeldsen, Frank ;
Giessing, Anders M. B. ;
Ingrell, Christian R. ;
Jensen, Ole N. .
ANALYTICAL CHEMISTRY, 2007, 79 (24) :9243-9252
[67]   Fragmentation of peptides in MALDI in-source decay mediated by hydrogen radicals [J].
Köcher, T ;
Engström, Å ;
Zubarev, RA .
ANALYTICAL CHEMISTRY, 2005, 77 (01) :172-177
[68]   ProSight PTM: an integrated environment for protein identification and characterization by top-down mass spectrometry [J].
LeDuc, RD ;
Taylor, GK ;
Kim, YB ;
Januszyk, TE ;
Bynum, LH ;
Sola, JV ;
Garavelli, JS ;
Kelleher, NL .
NUCLEIC ACIDS RESEARCH, 2004, 32 :W340-W345
[69]  
LEDUC RD, 2007, CURR PROTOC BIOINFOR, V13
[70]  
Lennon JJ, 1999, PROTEIN SCI, V8, P2487