Anatomic double-bundle posterior cruciate ligament reconstruction using hamstring tendons

被引:46
作者
Stähelin, AC
Südkamp, NP
Weiler, A
机构
[1] Humboldt Univ, Charite, Berlin, Germany
[2] Univ Freiburg, Trauma Dept, Freiburg, Germany
关键词
posterior cruciate ligament; double bundle; biodegradable interference screw; hamstring tendon;
D O I
10.1053/jars.2001.20661
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Recent biomechanical studies have shown that an anatomic double-bundle posterior cruciate ligament (PCL) reconstruction is superior in restoring normal knee laxity compared with the conventional single-bundle isometric reconstruction. We describe a modification of an endoscopic PCL reconstruction technique using a double-bundle Y-shaped hamstring tendon graft. A double- or triple-bundle semitendinosus-gracilis tendon graft is used and directly fixed with soft threaded biodegradable interference screws. In the medial femoral condyle, 2 femoral tunnels are created inside-out through a low anterolateral arthroscopic por-tal. First, in 80 degrees of flexion, the double-stranded gracilis graft is fixed with an interference screw inside the lower femoral socket, representing the insertion site of the posteromedial bundle. In full extension the combined semitendinosus-gracilis graft is pretensioned and fixed inside the posterior aspect of the single tibial tunnel. The double- or triple-stranded semitendinosus tendon is inserted in the higher femoral tunnel, presenting the insertion site of the anterolateral bundle. Finally, pretension is applied to the semitendinosus bundle in 70 degrees of flexion and a third screw is inserted. Using this technique, the stronger semitendinosus part of the double-bundle graft, which mimics the anterolateral bundle of the PCL, is fixed in flexion, whereas the smaller gracilis tendon part (posteromedial bundle) is fixed in full extension. Thus, a fully arthroscopic anatomic PCL reconstruction technique is available that may better restore normal knee kinematics as compared to the single-stranded isometric reconstruction.
引用
收藏
页码:88 / 97
页数:10
相关论文
共 53 条
[1]   PRELIMINARY-RESULTS OF AN ABSORBABLE INTERFERENCE SCREW [J].
BARBER, FA ;
ELROD, BF ;
MCGUIRE, DA ;
PAULOS, LE .
ARTHROSCOPY, 1995, 11 (05) :537-548
[2]   Graft fixation in cruciate ligament reconstruction [J].
Brand, J ;
Weiler, A ;
Caborn, DNM ;
Brown, CH ;
Johnson, DL .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (05) :761-774
[3]  
BROWN CH, 1993, CLIN SPORT MED, V12, P723
[4]  
CABORN DNM, 2000, ARTHROSCOPY, V16, P419
[5]  
CLANCY WG, 1994, CLIN SPORT MED, V13, P561
[6]  
GIRGIS FG, 1975, CLIN ORTHOP RELAT R, P216
[7]   FACTORS AFFECTING THE REGION OF MOST ISOMETRIC FEMORAL ATTACHMENTS .1. THE POSTERIOR CRUCIATE LIGAMENT [J].
GROOD, ES ;
HEFZY, MS ;
LINDENFIELD, TN .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1989, 17 (02) :197-207
[8]   Biomechanical analysis of a double-bundle posterior cruciate ligament reconstruction [J].
Harner, CD ;
Janaushek, MA ;
Kanamori, A ;
Yagi, M ;
Vogrin, TM ;
Woo, SLY .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (02) :144-151
[9]   Biomechanical analysis of a posterior cruciate ligament reconstruction -: Deficiency of the posterolateral structures as a cause of graft failure [J].
Harner, CD ;
Vogrin, TM ;
Höher, J ;
Ma, CB ;
Woo, SLY .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (01) :32-39
[10]   Evaluation and treatment of posterior cruciate ligament injuries [J].
Harner, CD ;
Hoher, J .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1998, 26 (03) :471-482