Acoustic emission monitoring of field tests of an operating wind turbine

被引:36
作者
Blanch, MJ [1 ]
Dutton, AG [1 ]
机构
[1] Rutherford Appleton Lab, CLRC, Energy Res Unit, Didcot OX11 0QX, Oxon, England
来源
DAMAGE ASSESSMENT OF STRUCTURES, PROCEEDINGS | 2003年 / 245-2卷
关键词
Acoustic Emission; condition monitoring; NDT; rotating machinery; wind turbine;
D O I
10.4028/www.scientific.net/KEM.245-246.475
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Acoustic Emission (AE) testing procedures developed during a laboratory blade testing programme have been applied to an in-service wind turbine blade: AE monitoring can both locate and characterise damage processes in blades, starting with non-audible signals occurring due to damage propagation at relatively low loads. The results of this assessment of the potential of blade in-service monitoring are sufficiently encouraging to justify further development.