Reliability of Orthodontic Miniscrews: Bending and Maximum Load of Different Ti-6Al-4V Titanium and Stainless Steel Temporary Anchorage Devices (TADs)

被引:18
作者
Scribante, Andrea [1 ]
Montasser, Mona A. [2 ]
Radwan, Eman Saad [2 ]
Bernardinelli, Luisa [3 ]
Alcozer, Roberto [1 ]
Gandini, Paola [1 ]
Sfondrini, Maria Francesca [1 ]
机构
[1] Univ Pavia, Dept Clin Surg Diagnost & Paediat Sci, Sect Dent, Unit Orthodont & Paediat Dent, I-27100 Pavia, Italy
[2] Mansoura Univ, Fac Dent, Orthodont Dept, Mansoura 35511, Egypt
[3] Univ Pavia, Dept Brain & Behav Sci, Sect Stat, I-27100 Pavia, Italy
关键词
anchorage; bend; dentistry; fracture; implant; load; miniscrew; orthodontics; shear; FIBER-REINFORCED COMPOSITES; MECHANICAL-PROPERTIES; FRACTURE-RESISTANCE; FLEXURAL STRENGTHS; MINI-IMPLANTS; RELEASE; MOVEMENT; BRACKETS; DIAMETER; TORQUE;
D O I
10.3390/ma11071138
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Temporary anchorage devices (TADs) have been introduced into orthodontic clinical practice in order to allow tooth movements while avoiding strain on adjacent teeth. Miniscrews are available in the market with different diameters and materials. Accordingly, the purpose of the present report was to measure and compare the forces to bend and fracture different mini implants. Ti-6Al-4V titanium and stainless steel TADs of different manufacturers (Spider ScrewHDC; Mini Implants-Leone; Benefit-Orteam; Storm-Kristal) were evaluated. Two different diameters (1.5 mm and 2.0 mm) were tested. The sample included 10 unused specimens for each group, blocked in an Instron Universal Testing Machine, and a shear load was applied at the neck of the miniscrew. The force to bend the miniscrew was measured at 0.1 mm and 0.2 mm deflections. Also, the maximum force before screw fracture was recorded. Data were submitted for statistical analysis. Results showed significantly higher forces for 2.0 mm than 1.5 mm screws, both at 0.1 mm and 0.2 mm deflections and at maximum load. Moreover, no significant differences were reported between titanium and stainless steel miniscrews of equal diameters.
引用
收藏
页数:10
相关论文
共 49 条
  • [1] Miniscrew implant fracture and effects of such retained tip on dentin-pulp complex: a histological report
    Ahmed, Valai Kasim Shakeel
    Krishnaswamy, Nathamuni Rengarajan
    Thavarajah, Rooban
    [J]. DENTAL TRAUMATOLOGY, 2016, 32 (02) : 161 - 165
  • [2] Ajami Shabnam, 2016, J Orthod Sci, V5, P64, DOI 10.4103/2278-0203.179416
  • [3] Evaluation of the Efect of Platelet-Released Growth Factor and Immediate Orthodontic Loading on the Removal Torque of Miniscrews
    Bayani, Shahin
    Masoomi, Fatemeh
    Aghaabbasi, Sharereh
    Farsinejad, Alireza
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (02) : 471 - 477
  • [4] Comparison of stainless steel and titanium alloy orthodontic miniscrew implants: A mechanical and histologic analysis
    Brown, Ryan N.
    Sexton, Brent E.
    Chu, Tien-Min Gabriel
    Katona, Thomas R.
    Stewart, Kelton T.
    Kyung, Hee-Moon
    Liu, Sean Shih-Yao
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 145 (04) : 496 - 504
  • [5] A 12 month clinical study of bond failures of recycled versus new stainless steel orthodontic brackets
    Cacciafesta, V
    Sfondrini, MF
    Melsen, B
    Scribante, A
    [J]. EUROPEAN JOURNAL OF ORTHODONTICS, 2004, 26 (04) : 449 - 454
  • [6] Force levels of fiber-reinforced composites and orthodontic stainless steel wires: A 3-point bending test
    Cacciafesta, Vittorio
    Sfondrini, Maria Francesca
    Lena, Alessandro
    Scribante, Andrea
    Vallittu, Pekka K.
    Lassila, Lippo V.
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 133 (03) : 410 - 413
  • [7] Flexural strengths of fiber-reinforced composites polymerized with conventional light-curing and additional postcuring
    Cacciafesta, Vittorio
    Sfondrini, Maria Francesca
    Lena, Alessandro
    Scribante, Andrea
    Vallittu, Pekka K.
    Lassila, Lippo V.
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 132 (04) : 524 - 527
  • [8] Carano Aldo, 2005, Prog Orthod, V6, P82
  • [9] Effects of thread depth, taper shape, and taper length on the mechanical properties of mini-implants
    Chang, Jenny Zwei-Chieng
    Chen, Yi-Jane
    Tung, Yuan-Yi
    Chiang, Yu-Ying
    Lai, Eddie Hsiang-Hua
    Chen, Weng-Pin
    Lin, Chun-Pin
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 141 (03) : 279 - 288
  • [10] Chung K, 2005, ANGLE ORTHOD, V75, P119