Rapid and simultaneous determination of amoxicillin, penicillin G, and their major metabolites in bovine milk by ultra-high-performance liquid chromatography-tandem mass spectrometry

被引:59
|
作者
Liu, Chuangji [1 ]
Wang, Hai [2 ]
Jiang, Yanbin [2 ]
Du, Zhenxia [1 ]
机构
[1] Beijing Univ Chem Technol, Coll Sci, Beijing 100029, Peoples R China
[2] China Anim Dis Control Ctr, Beijing 100125, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2011年 / 879卷 / 7-8期
关键词
Ultra-high-performance liquid; Chromatography-tandem mass spectrometry; Amoxicillin; Penicillin G; Metabolite; Bovine milk; BETA-LACTAM ANTIBIOTICS; SOLID-PHASE EXTRACTION; ELECTROSPRAY-IONIZATION; QUANTITATIVE-DETERMINATION; DEGRADATION-PRODUCTS; LC-MS/MS; RESIDUES; CONFIRMATION; TISSUES; QUANTIFICATION;
D O I
10.1016/j.jchromb.2011.01.016
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid, sensitive, and specific method for the determination of amoxicillin (AMO), amoxicilloic acid (AMA), amoxicillin diketopiperazine-2',5'-dione (DIKETO), penicillin G (PEN G), benzylpenicilloic acid (BPA-1), benzylpenilloic acid (BPA-2), and benzylpenillic acid (BPA-3) in bovine milk using ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) was developed and validated. The method used penicillin V (PEN V) as the internal standard and ethanol for the deproteinisation of bovine milk. Chromatographic separation of the components was performed on a Waters Acquity UPLC (R) HSS T3 column (100 mm x 2.1 mm, 1.8 mu m) using a mixture of 0.15% formic acid in water with 5 mM ammonium acetate and acetonitrile as the mobile phase. Gradient elution was performed at a flow rate of 0.25 mL min(-1). The mass spectrometer was operated in the positive electrospray ionisation MS/MS mode. The method was fully validated according to EU requirements, including linearity, precision, trueness, limit of quantification, limit of detection, and specificity. The results were within the ranges specified. The established method was successfully applied in the determination of AMO, PEN G, and their major metabolites in 40 commercial bovine milk samples. The results showed that 8 samples were contaminated with BPA-1 or BPA-2. The mean levels (occurrence) of BPA-1 and BPA-2 in positive samples were 287 (50%) and 320(100%) ng mL(-1), respectively. No sample was found to be contaminated with AMO, AMA, DIKETO, PEN G, and BPA-3. These findings could play an important role in food safety, because BPA-1 and BPA-2 metabolites pose possible health risks, although they are not included in the maximum residue limit legislation. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:533 / 540
页数:8
相关论文
共 50 条
  • [31] Determination of Flupyradifurone and Its Metabolites in Milk Using QuEChERS and Ultra-high Performance Liquid Chromatography-Tandem Mass Spectrometry
    Chen Y.
    Lin H.
    Xiao Q.
    Song J.
    Liu C.
    Dai Q.
    Shipin Kexue/Food Science, 2024, 45 (12): : 285 - 291
  • [32] Development and Validation of a Rapid and Efficient Method for Simultaneous Determination of Scopolin and Scopoletin in Convolvulus Species by Ultra-high-performance Liquid Chromatography-Tandem Mass Spectrometry
    Al-Rifai, Asma'a
    Aqel, Ahmad
    Al-Saleem, Muneera
    CURRENT PHARMACEUTICAL ANALYSIS, 2020, 16 (05) : 494 - 503
  • [33] Simultaneous determination of bovine α-lactalbumin and bovine β-lactoglobulin in milk powders by ultra-high performance liquid chromatography tandem mass spectrometry
    Zhang, Yu
    Mao, Lei
    Ren, Yiping
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [34] Simultaneous determination of three sulfonamide residues in modified milk by ultra performance liquid chromatography-tandem mass spectrometry
    Cheng Guodong
    Wu Xiaohui
    Jin Zhu
    Zhang Yu
    Hao Dan
    Tong Mianhuan
    Gao Jianjun
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2015, 33 (08) : 892 - 896
  • [35] Simultaneous Determination of 24 Antidepressant Drugs and Their Metabolites in Wastewater by Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry
    Sheng, Ling-Hui
    Chen, Hong-Rui
    Huo, Ying-Bin
    Wang, Jing
    Zhang, Yu
    Yang, Min
    Zhang, Hong-Xun
    MOLECULES, 2014, 19 (01) : 1212 - 1222
  • [36] Fast and multiresidue determination of twenty glucocorticoids in bovine milk using ultra high performance liquid chromatography-tandem mass spectrometry
    Deceuninck, Y.
    Bichon, E.
    Monteau, F.
    Dervilly-Pinel, G.
    Antignac, J. P.
    Le Bizec, B.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1294 : 76 - 86
  • [37] Determination of sulbactam in raw bovine milk by isotope dilution-ultra-high-performance liquid chromatography-tandem mass spectrometry
    Li, P.
    Zhang, Y. D.
    Li, S. L.
    Wen, F.
    Li, H. Y.
    Zhao, S. G.
    Zheng, N.
    Wang, J. Q.
    JOURNAL OF DAIRY SCIENCE, 2019, 102 (11) : 9605 - 9610
  • [38] Simultaneous Determination of Artemether and Its Major Metabolites Dihydroartimisinin in Rat Plasma Using Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
    Li Chun
    Qiu Yu-Qin
    Yang Guo-Zhong
    Meng Fan-Da
    Zhang Suo-Hui
    Gao Yun-Hua
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (04) : 560 - 565
  • [39] Determination of Isomaltooligosaccharides in Milk Powder by Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry
    Jiao, Yanni
    Li, Fenghua
    Jiang, Dafeng
    Li, Wei
    Chen, Jindong
    ANALYTICAL LETTERS, 2016, 49 (04) : 458 - 466
  • [40] Immunoaffinity chromatography purification and ultra-high-performance liquid chromatography-tandem mass spectrometry determination of four β-agonists in beef
    Lin, Q. -B.
    Zhao, X. -T.
    Song, H.
    Pan, Y. -L.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2012, 29 (06): : 935 - 941