Development of Highly Sensitive Immunosensor for Clenbuterol Detection by Using Poly(3,4-ethylenedioxythiophene)/Graphene Oxide Modified Screen-Printed Carbon Electrode

被引:28
作者
Talib, Nurul Ain A. [1 ,2 ]
Salam, Faridah [3 ]
Sulaiman, Yusran [1 ,2 ]
机构
[1] Univ Putra Malaysia, Inst Adv Technol, Funct Devices Lab, Serdang 43400, Selangor, Malaysia
[2] Univ Putra Malaysia, Fac Sci, Dept Chem, Serdang 43400, Selangor, Malaysia
[3] Malaysian Agr Res & Dev Inst, Biotechnol & Nanotechnol Res Ctr, Biodiagnost Biosensor Programme, Serdang 43400, Selangor, Malaysia
关键词
clenbuterol; poly(3,4-ethylenedioxythiophene); graphene oxide; immunosensor; electrochemical; GRAPHENE OXIDE; ELECTROCHEMICAL IMMUNOSENSOR; PORTABLE DETECTION; NANOTUBE; SENSOR; PEDOT; MILK; RACTOPAMINE; BIOSENSOR; DOPAMINE;
D O I
10.3390/s18124324
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Clenbuterol (CLB) is an antibiotic and illegal growth promoter drug that has a long half-life and easily remains as residue and contaminates the animal-based food product that leads to various health problems. In this work, electrochemical immunosensor based on poly(3,4-ethylenedioxythiophene)/graphene oxide (PEDOT/GO) modified screen-printed carbon electrode (SPCE) for CLB detection was developed for antibiotic monitoring in a food product. The modification of SPCE with PEDOT/GO as a sensor platform was performed through electropolymerization, while the electrochemical assay was accomplished while using direct competitive format in which the free CLB and clenbuterol-horseradish peroxidase (CLB-HRP) in the solution will compete to form binding with the polyclonal anti-clenbuterol antibody (Ab) immobilized onto the modified electrode surface. A linear standard CLB calibration curve with R-2 = 0.9619 and low limit of detection (0.196 ng mL(-1)) was reported. Analysis of milk samples indicated that this immunosensor was able to detect CLB in real samples and the results that were obtained were comparable with enzyme-linked immunosorbent assays (ELISA).
引用
收藏
页数:13
相关论文
共 55 条
[1]  
[Anonymous], J FUTUR MARK
[2]   Effect of electropolymerization potential on the preparation of PEDOT/graphene oxide hybrid material for supercapacitor application [J].
Azman, Nur Hawa Nabilah ;
Lim, Hong Ngee ;
Sulaiman, Yusran .
ELECTROCHIMICA ACTA, 2016, 188 :785-792
[3]   Graphene oxide/conducting polymer composite hydrogels [J].
Bai, Hua ;
Sheng, Kaixuan ;
Zhang, Pengfei ;
Li, Chun ;
Shi, Gaoquan .
JOURNAL OF MATERIALS CHEMISTRY, 2011, 21 (46) :18653-18658
[4]   Recent developments on graphene and graphene oxide based solid state gas sensors [J].
Basu, S. ;
Bhattacharyya, P. .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 173 :1-21
[5]   PEDOT-modified integrated microelectrodes for the detection of ascorbic acid, dopamine and uric acid [J].
Belaidi, F. Sekli ;
Civelas, A. ;
Castagnola, V. ;
Tsopela, A. ;
Mazenq, L. ;
Gros, P. ;
Launay, J. ;
Temple-Boyer, P. .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 214 :1-9
[6]   Ultrafast Graphene Oxide Humidity Sensors [J].
Borini, Stefano ;
White, Richard ;
Wei, Di ;
Astley, Michael ;
Haque, Samiul ;
Spigone, Elisabetta ;
Harris, Nadine ;
Kivioja, Jani ;
Ryhanen, Tapani .
ACS NANO, 2013, 7 (12) :11166-11173
[7]   Clinical and pharmacological profile in a clenbuterol epidemic poisoning of contaminated beef meat in Italy [J].
Brambilla, G ;
Cenci, T ;
Franconi, F ;
Galarini, R ;
Macrì, A ;
Rondoni, F ;
Strozzi, M ;
Loizzo, A .
TOXICOLOGY LETTERS, 2000, 114 (1-3) :47-53
[8]   A sensitive solid-state electrochemiluminescence sensor for clenbuterol relying on a PtNPs/RuSiNPs/Nafion composite modified glassy carbon electrode [J].
Chen, Xiaomei ;
Wu, Rongrong ;
Sun, Lechang ;
Yao, Qiuhong ;
Chen, Xi .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 781 :310-314
[9]   Highly Sensitive Detection of Clenbuterol in Animal Urine Using Immunomagnetic Bead Treatment and Surface-Enhanced Raman Spectroscopy [J].
Cheng, Jie ;
Su, Xiao-Ou ;
Wang, Shi ;
Zhao, Yiping .
SCIENTIFIC REPORTS, 2016, 6
[10]   Disposable amperometric magneto-immunosensor for direct detection of tetracyclines antibiotics residues in milk [J].
Conzuelo, Felipe ;
Gamella, Maria ;
Campuzano, Susana ;
Julio Reviejo, A. ;
Pingarron, Jose M. .
ANALYTICA CHIMICA ACTA, 2012, 737 :29-36