Early Kidney Graft Size and Doppler Parameters Are Associated With Kidney Graft Function 1 Year After Transplantation

被引:9
|
作者
Buturovic-Ponikvar, J. [1 ]
Cerne, S. [1 ]
Arnol, M. [1 ]
Kandus, A. [1 ]
Ponikvar, R. [1 ]
Bren, A. [1 ]
机构
[1] Univ Med Ctr Ljubljana, Dept Nephrol, Ljubljana 1525, Slovenia
关键词
SYSTEMIC ATHEROSCLEROSIS; RESISTANCE INDEXES; ALLOGRAFT SURVIVAL; RENAL-ALLOGRAFTS; PREDICTION; RECIPIENTS; MASS;
D O I
10.1016/j.transproceed.2010.09.053
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. The aim of this study was to assess the association of various ultrasonography (US) and Doppler parameters of kidney graft as measured at 1 month posttransplant with 1-year graft function. Materials and Methods. The study cohort included 125 adult recipients of deceased donor kidney transplantations between January 2006 and February 2009. All patients underwent an US-Doppler examination performed by a trained nephrologist at 1 month posttransplant using an Acuson-Siemens Sequoia 512. Graft length and intrarenal Doppler indices were measured at the midsegmental artery level. Relative graft size was calculated by dividing graft length with body mass index. Graft function was assessed at 1 year by estimated glomerular filtration rate (eGFR) using the 4-variable Modification of Diet in Real Disease study equation. Linear and logistic regression analyses were used to assess the relationship between US Doppler parameters and eGFR. Results. Univariate linear regression showed a significant correlation between eGFR at 1 year and graft length at 1 month (P = .009), relative graft length <0.50 cm per kg/m(2) (P = .004), resistance index >0.75 (P = .031), and end-diastolic velocity <9 cm/sec (P = .006). Logistic regression analyses showed that eGFR <60 mL/min/1.73 m(2) at 1 year was significantly associated with graft length <12 cm at 1 month (odds ratio [OR], 2.4; 95% confidence interval [CI], 1.16-4.92; P = .017), relative graft length <0.5 cm per kg/m(2) (OR, 2.54; 95% CI, 1.20-5.35; P = .014), resistance index >0.75 (OR, 2.86; 95% CI, 1.30-6.29; P = .009), and end-diastolic velocity <9 cm/sec (OR, 2.37; 95% CI, 1.01-5.56; P = .047). Conclusion. In this retrospective analysis, kidney transplant recipients with greater graft length at 1 month, specifically when standardized to body size, showed better graft function at 1 year posttransplantation. Higher intrarenal diastolic blood flow and lower resistance index at 1 month were also predictive of better graft function at 1 year.
引用
收藏
页码:4026 / 4029
页数:4
相关论文
共 50 条
  • [1] Kidney graft functionality 1 year after kidney transplantation
    Hernandez-Rivera, Juan C. H.
    Espinoza-Perez, Ramon
    Cruz-Santiago, Jose
    Rodriguez-Gomez, Raul
    Meza-Jimenez, Guillermo
    Cancino-Lopez, Jorge D.
    Cruz-Lopez, Martha
    Juana Perez-Lopez, M.
    Santos-Caballero, Marlene
    Salazar-Mendoza, Mariana
    Paniagua-Sierra, Ramon
    CIRUGIA Y CIRUJANOS, 2022, 90 (01): : 90 - 99
  • [2] Doppler Ultrasonographic Assessment of Early Changes in Kidney Graft Size and Resistive Index and Their Predictive Role on 1-Year Graft Function
    Mohammadi, A.
    Biniaz, F.
    Nikoobakht, M. R.
    Barbari, G. R.
    TRANSPLANTATION PROCEEDINGS, 2013, 45 (01) : 172 - 174
  • [3] Impact of Early Hospital Readmissions After Kidney Transplantation on Graft Function
    Kang, I. -C.
    Kim, I. -K.
    Son, S.
    Ju, M. K.
    TRANSPLANTATION PROCEEDINGS, 2018, 50 (08) : 2359 - 2362
  • [4] Decrease in 1-year Kidney Graft Size Predicts Inferior Outcomes After Deceased Donor Kidney Transplantation
    Cerne, Senka
    Arnol, Miha
    Kandus, Aljosa
    Buturovic-Ponikvar, Jadranka
    TRANSPLANTATION, 2016, 100 (08) : 1759 - 1766
  • [5] Delayed Graft Function in Kidney Transplantation: Risk Factors and Impact on Early Graft Function
    Tugmen, Cem
    Sert, Ismail
    Kebabci, Eyup
    Dogan, Sait Murat
    Tanrisev, Mehmet
    Alparslan, Caner
    Ayna, Tulay Kilicaslan
    Olmez, Mustafa
    Karaca, Cezmi
    PROGRESS IN TRANSPLANTATION, 2016, 26 (02) : 172 - 177
  • [6] Graft function and pregnancy outcomes after kidney transplantation
    Schwarz, Anke
    Schmitt, Roland
    Einecke, Gunilla
    Keller, Frieder
    Bode, Ulrike
    Haller, Hermann
    Guenter, Hans Heinrich
    BMC NEPHROLOGY, 2022, 23 (01)
  • [7] Influence of Body Mass on Kidney Graft Function in Patients After Kidney Transplantation
    Malgorzewicz, S.
    Debska-Slizien, A.
    Czajka, B.
    Owczarzak, A.
    Rutkowski, B.
    TRANSPLANTATION PROCEEDINGS, 2016, 48 (05) : 1472 - 1476
  • [8] Subclinical Left Ventricular Echocardiographic Abnormalities 1 Year after Kidney Transplantation Are Associated with Graft Function and Future Cardiovascular Events
    Arnol, M.
    Knap, B.
    Oblak, M.
    Buturovic-Ponikvar, J.
    Bren, A. F.
    Kandus, A.
    TRANSPLANTATION PROCEEDINGS, 2010, 42 (10) : 4064 - 4068
  • [9] Anemia and Erythrocytosis After Kidney Transplantation: A 5-Year Graft Function and Survival Analysis
    Kolonko, A.
    Pinocy-Mandok, J.
    Kocierz, M.
    Kujawa-Szewieczek, A.
    Chudek, J.
    Malyszko, J.
    Malyszko, J. S.
    Mysliwiec, M.
    Wiecek, A.
    TRANSPLANTATION PROCEEDINGS, 2009, 41 (08) : 3046 - 3051
  • [10] Delayed Graft Function: The AKI of Kidney Transplantation
    Mannon, Roslyn B.
    NEPHRON, 2018, 140 (02) : 94 - 98