Distinguishing recurrent nasal tumor from post-treatment changes by dynamic MR images

被引:0
作者
Huang, WC [1 ]
Hsu, CC [1 ]
Lai, PH [1 ]
Lee, CN [1 ]
机构
[1] Chia Nan Coll Pharm & Sci, Dept Management Informat Sci, Tainan, Taiwan
来源
CISST'98: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON IMAGING SCIENCE, SYSTEMS AND TECHNOLOGY | 1998年
关键词
magnetic resonance imaging; segmentation; relative signal increase; active contour;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The purpose of this research is to detect and enhance the tumor. region by computing the relative intensity difference between consecutive MR images after using contrast agents. We apply a relative signal increase (RSI) model to recognize the recurrent nasal tumor from dynamic MR images. Image registration is required to deal with the matching corresponding points among different images. The phase correlation technique and function minimization is used for image registration. The active contour technique is used to refine the region of interest automatically and more precise to define the interested a,sa. The quantitative evaluation of dynamic MR data is modeled by fitting the three-parameter time-intensity curves. From The color distribution of rime constant for arrival of contrast intensity and enhancement amplitude and the color representation in the final images show that our proposed method can identify the nasal tumor effectively. The results enhance the clinical diagnosis function and greatly increase the precision of the recurrent nasal tumor detection.
引用
收藏
页码:119 / 124
页数:5
相关论文
共 28 条
  • [1] [Anonymous], 1975, PROC INT C CYBERN SO
  • [2] Bankman I N, 1997, IEEE Trans Inf Technol Biomed, V1, P141, DOI 10.1109/4233.640656
  • [3] A SURVEY OF IMAGE REGISTRATION TECHNIQUES
    BROWN, LG
    [J]. COMPUTING SURVEYS, 1992, 24 (04) : 325 - 376
  • [4] Deformable boundary finding in medical images by integrating gradient and region information
    Chakraborty, A
    Staib, LH
    Duncan, JS
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (06) : 859 - 870
  • [5] A multiple active contour model for cardiac boundary detection on echocardiographic sequences
    Chalana, V
    Linker, DT
    Haynor, DR
    Kim, YM
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (03) : 290 - 298
  • [6] Image registration based on boundary mapping
    Davatzikos, C
    Prince, JL
    Bryan, RN
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (01) : 112 - 115
  • [7] A physics-based coordinate transformation for 3-D image matching
    Davis, MH
    Khotanzad, A
    Flamig, DP
    Harms, SE
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (03) : 317 - 328
  • [8] ENANDER EP, 1996, MATLAB HDB
  • [9] EPICARDIAL BOUNDARY DETECTION USING FUZZY-REASONING
    FENG, J
    LIN, WC
    CHEN, CT
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (02) : 187 - 199
  • [10] Spatial registration and normalization of images
    Friston, KJ
    Ashburner, J
    Frith, CD
    Poline, JB
    Heather, JD
    Frackowiak, RSJ
    [J]. HUMAN BRAIN MAPPING, 1995, 3 (03) : 165 - 189