Macular Retinal Ganglion Cell-Inner Plexiform Layer Thickness in Patients on Hydroxychloroquine Therapy

被引:36
作者
Lee, Min Gyu [1 ]
Kim, Sang Jin [1 ]
Ham, Don-Il [1 ]
Kang, Se Woong [1 ]
Kee, Changwon [1 ]
Lee, Jaejoon [2 ]
Cha, Hoon-Suk [2 ]
Koh, Eun-Mi [2 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Ophthalmol, Seoul 135710, South Korea
[2] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Div Rheumatol,Dept Med, Seoul 135710, South Korea
关键词
hydroxychloroquine; retinal ganglion cell; hydroxychloroquine retinopathy; OPTICAL COHERENCE TOMOGRAPHY; GLAUCOMA DIAGNOSTIC-ACCURACY; RETINITIS-PIGMENTOSA; CHLOROQUINE RETINOPATHY; POLYCYCLIC COMPOUNDS; TOXICITY; HISTOPATHOLOGY; EPITHELIUM; EXPOSURE;
D O I
10.1167/iovs.14-15138
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. We evaluated macular ganglion cell-inner plexiform layer (GC-IPL) thickness using spectral-domain optical coherence tomography (SD-OCT) in patients with chronic exposure to hydroxychloroquine (HCQ). METHODS. This study included 130 subjects, who were divided into three groups: Group 1A, 55 patients with HCQ use >5 years; Group 1B, 46 patients with HCQ use <5 years; and Group 2, 29 normal controls. In all patients with exposure to HCQ, fundus examination, automated threshold perimetry, fundus autofluorescence photography, SD-OCT, and GC-IPL thickness measurement using the Cirrus HD-OCT ganglion cell analysis algorithm were performed. Average and minimum macular GC-IPL thickness were compared between subjects groups, and correlations between GC-IPL thickness and duration or total dose of HCQ use were analyzed. RESULTS. Among the 101 patients of Group 1, six patients who showed clinically evident HCQ retinopathy also showed markedly thin macular GC-IPL. In addition, weak but significant negative correlations were observed between the average and minimum GC-IPL thickness of Group 1 patients and cumulative dose of HCQ, even when analyzing without the six patients with HCQ retinopathy. However, when analyzing after exclusion of patients with high cumulative doses (>1000 g), significant correlations were not observed. CONCLUSIONS. This study revealed that macular GC-IPL thickness did not show definite correlations with HCQ use. However, some patients, especially with HCQ retinopathy or high cumulative doses, showed thin GC-IPL.
引用
收藏
页码:396 / 402
页数:7
相关论文
共 31 条
[1]   IRREVERSIBLE LYSOSOMAL DAMAGE INDUCED BY CHLOROQUINE IN RETINAE OF PIGMENTED AND ALBINO RATS [J].
ABRAHAM, R ;
HENDY, RJ .
EXPERIMENTAL AND MOLECULAR PATHOLOGY, 1970, 12 (02) :185-&
[2]  
BERNSTEIN H, 1964, ARCH OPHTHALMOL-CHIC, V71, P238
[3]  
Bernstein H N, 1967, Surv Ophthalmol, V12, P415
[4]   OCULAR CHANGES IN SWINE ASSOCIATED WITH CHLOROQUINE TOXICITY [J].
GLEISER, CA ;
DUKES, TW ;
LAWWILL, T ;
READ, WK ;
BAY, WW ;
BROWN, RS .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1969, 67 (03) :399-+
[5]  
GONASUN LM, 1974, INVEST OPHTH VISUAL, V13, P107
[6]  
HALLBERG A, 1990, ACTA OPHTHALMOL, V68, P125
[7]  
HODGKINSON J, 1970, ARCH OPHTHALMOL-CHIC, V84, P509
[8]   Thickness of Receptor and Post-receptor Retinal Layers in Patients with Retinitis Pigmentosa Measured with Frequency-Domain Optical Coherence Tomography [J].
Hood, Donald C. ;
Lin, Christine E. ;
Lazow, Margot A. ;
Locke, Kirsten G. ;
Zhang, Xian ;
Birch, David G. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (05) :2328-2336
[9]   Macular Ganglion Cell Imaging Study: Glaucoma Diagnostic Accuracy of Spectral-Domain Optical Coherence Tomography [J].
Jeoung, Jin Wook ;
Choi, Yun Jeong ;
Park, Ki Ho ;
Kim, Dong Myung .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (07) :4422-4429
[10]   Structure-Function Relationship and Diagnostic Value of Macular Ganglion Cell Complex Measurement Using Fourier-Domain OCT in Glaucoma [J].