Table-top water-window soft X-ray microscope using a Z-pinching capillary discharge source

被引:11
作者
Nawaz, M. F. [1 ]
Nevrkla, M. [1 ]
Jancarek, A. [1 ,2 ,3 ]
Torrisi, A. [2 ]
Parkman, T. [3 ]
Turnova, J. [3 ]
Stolcova, L. [1 ]
Vrbova, M. [3 ]
Limpouch, J. [1 ]
Pina, L. [1 ]
Wachulak, P. [2 ]
机构
[1] Czech Tech Univ, Fac Nucl Sci & Phys Engn, Brehova 7, CR-11519 Prague 1, Czech Republic
[2] Mil Univ Technol, Inst Optoelect, Kaliskiego 2 Str, PL-00908 Warsaw, Poland
[3] Czech Tech Univ, Fac Biomed Engn, Sitna Sq 3105, Kladno 27201 2, Czech Republic
来源
JOURNAL OF INSTRUMENTATION | 2016年 / 11卷
关键词
Inspection with x-rays; Interaction of radiation with matter; Optics; X-ray generators and sources; GAS-PUFF TARGET; NM SPATIAL-RESOLUTION; COMPACT; PLASMA;
D O I
10.1088/1748-0221/11/07/P07002
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The development and demonstration of a table-top transmission soft X-ray (SXR) microscope, using a laboratory incoherent capillary discharge source has been carried out. This Z-pinching capillary discharge water-window SXR source, is a first of its kind to be used for high spatial resolution microscopy at lambda = 2.88 nm (430 eV). A grazing incidence ellipsoidal condenser mirror is used for focusing of the SXR radiation at the sample plane. The Fresnel zone plate objective lens is used for imaging of the sample onto a back-illuminated (BI) CCD camera. The achieved half-pitch spatial resolution of the microscope approaches 100 nm, as demonstrated by the knife-edge test. Details about the source, and the construction of the microscope are presented and discussed. Additionally, the SXR images of various samples, proving applicability of such microscope for observation of objects in the nanoscale, are shown.
引用
收藏
页数:13
相关论文
共 16 条
[1]  
Attwood D., 1999, SOFT XRAYS EXTREME U
[2]   Compact soft x-ray microscope using a gas-discharge light source [J].
Benk, Markus ;
Bergmann, Klaus ;
Schaefer, David ;
Wilhein, Thomas .
OPTICS LETTERS, 2008, 33 (20) :2359-2361
[3]   Demonstration of 12 nm Resolution Fresnel Zone Plate Lens based Soft X-ray Microscopy [J].
Chao, Weilun ;
Kim, Jihoon ;
Rekawa, Senajith ;
Fischer, Peter ;
Anderson, Erik H. .
OPTICS EXPRESS, 2009, 17 (20) :17669-17677
[4]   Compact soft x-ray transmission microscopy with sub-50 nm spatial resolution [J].
Kim, KW ;
Kwon, Y ;
Nam, KY ;
Lim, JH ;
Kim, KG ;
Chon, KS ;
Kim, BH ;
Kim, DE ;
Kim, J ;
Ahn, BN ;
Shin, HJ ;
Rah, S ;
Kim, KH ;
Chae, JS ;
Gweon, DG ;
Kang, DW ;
Kang, SH ;
Min, JY ;
Choi, KS ;
Yoon, SE ;
Kim, EN ;
Namba, Y ;
Yoon, KH .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (06) :N99-N107
[5]   A compact Laboratory Transmission X-ray Microscope for the water window [J].
Legall, H. ;
Stiel, H. ;
Blobel, G. ;
Seim, C. ;
Baumann, J. ;
Yulin, S. ;
Esser, D. ;
Hoefer, M. ;
Wiesemann, U. ;
Wirtz, M. ;
Schneider, G. ;
Rehbein, S. ;
Hertz, H. M. .
11TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY (XRM2012), 2013, 463
[6]   Table-top soft x-ray microscope using laser-induced plasma from a pulsed gas jet [J].
Mueller, Matthias ;
Mey, Tobias ;
Niemeyer, Juergen ;
Mann, Klaus .
OPTICS EXPRESS, 2014, 22 (19) :23489-23495
[7]   Focusing and photon-flux measurements of the 2.88 nm radiation at the sample plane of the Soft X-ray microscope, based on capillary discharge source [J].
Nawaz, M. Fahad ;
Jancarek, Alexandr ;
Nevrkla, Michal ;
Wachulak, Przemyslaw ;
Limpouch, Jiri ;
Pina, Ladislav .
EUV AND X-RAY OPTICS: SYNERGY BETWEEN LABORATORY AND SPACE IV, 2015, 9510
[8]  
Nevrkla M., 2012, INT WORKSH EUV SOFT
[9]  
Novak J., 2012, INT WORKSH EUV SOFT
[10]  
Powell K, 2011, AIP CONF PROC, V1365, P128, DOI 10.1063/1.3625321