Feasibility of Atrial Fibrillation Screening With Mobile Health Technologies at Pharmacies

被引:21
作者
Zaprutko, Tomasz [1 ]
Zaprutko, Joanna [2 ]
Baszko, Artur [2 ]
Sawicka, Dominika [3 ]
Szalek, Anna [3 ,4 ]
Dymecka, Magdalena [3 ]
Telec, Wojciech [2 ]
Kopciuch, Dorota [1 ]
Ratajczak, Piotr [1 ]
Michalak, Michal [5 ]
Rafal, Dankowski [2 ]
Szyszka, Andrzej [2 ]
Nowakowska, Elzbieta [1 ]
机构
[1] Poznan Univ Med Sci, Dept Pharmacoecon & Social Pharm, Rokietnicka 7 St, PL-60806 Poznan, Poland
[2] Poznan Univ Med Sci, HCP Med Ctr, Dept Cardiol 2, Poznan, Poland
[3] Poznan Univ Med Sci, Dept Pharmacoecon & Social Pharm, Student Sci Soc, Poznan, Poland
[4] Poznan Univ Med Sci, HCP Med Ctr, Dept Cardiol 2, Student Sci Soc, Poznan, Poland
[5] Poznan Univ Med Sci, Dept Comp Sci & Stat, Poznan, Poland
关键词
atrial fibrillation; screening; mobile health technologies; pharmacy; ALIVECOR HEART MONITOR; IPHONE ECG; COST-EFFECTIVENESS; STROKE PREVENTION; EPIDEMIOLOGY;
D O I
10.1177/1074248419879089
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Atrial fibrillation (AF) is the most common cardiac arrhythmia. Thus, the aim of our study was to evaluate the smartphone-based electrocardiogram (ECG) recordings aimed at AF screening at Polish pharmacies. Methods: Prospective AF screening among patients aged >= 65 years was conducted at 10 pharmacies using Kardia Mobile with a dedicated application (Kardia app). Prior AF was a study exclusion criterion. CHA(2)DS(2)-VASc score (congestive heart failure, hypertension, age, diabetes mellitus, previous stroke/transient ischemic attack, female sex, and vascular disease) has been collected from every patient. A single-lead ECG has been acquired by the placement of fingers from each hand on the pads. Kardia app diagnosis has been evaluated by the cardiologist. Results: A total of 525 ECGs were performed. Kardia app diagnosis was provided in 490 cases. In 437 (89.18%) cases, it was "normal" rhythm, in 17 (3.47%) recordings "possible AF," in 23 (4.69%) ECGs "unreadable," and in 13 (2.65%) "unclassified". After the cardiologist reevaluation, the new AF was identified in 7 (1.33%) patients. Sensitivity and specificity of Kardia app in detecting AF was 100% (95% confidence interval [CI]: 71.5%-100%) and 98.7% (95% CI: 97.3%-99.5%), respectively. The positive predictive value was 64.7% (95% CI: 38.3%-85.7%) and the negative predictive value was 100% (95% CI: 99.2%-100%). CHA(2)DS(2)-VASc score was 2.14 +/- 0.69 for those with new AF and 3.33 +/- 1.26 in the non-AF group. Conclusion: Kardia app is capable of fast screening and detecting AF with high sensitivity and specificity. The possible diagnosis of AF deserves additional cardiological evaluation. The results obtained in patients with low CHA(2)DS(2)-VASc score and "silent" AF confirm the importance of routine AF screening. Cardiovascular screening with the use of mobile health technology is feasible at pharmacies.
引用
收藏
页码:142 / 151
页数:10
相关论文
共 31 条
[1]  
AliveCor, FDA CLEAR EKG YOUR F
[2]  
AliveCor and OMRON Connect TM, 2019, USER MANUALFORKARDIA
[3]   Cost-effectiveness of mass screening for untreated atrial fibrillation using intermittent ECG recording [J].
Aronsson, Mattias ;
Svennberg, Emma ;
Rosenqvist, Marten ;
Engdahl, Johan ;
Al-Khalili, Faris ;
Friberg, Leif ;
Frykman-Kull, Viveka ;
Levin, Lars-Ake .
EUROPACE, 2015, 17 (07) :1023-1029
[4]   Use of community pharmacies: a population-based survey [J].
Boardman, H ;
Lewis, M ;
Trinder, P ;
Rajaratnam, G ;
Croft, P .
JOURNAL OF PUBLIC HEALTH, 2005, 27 (03) :254-262
[5]   Diagnostic Performance of a Smartphone-Based Photoplethysmographic Application for Atrial Fibrillation Screening in a Primary Care Setting [J].
Chan, Pak-Hei ;
Wong, Chun-Ka ;
Poh, Yukkee C. ;
Pun, Louise ;
Leung, Wangie Wan-Chiu ;
Wong, Yu-Fai ;
Wong, Michelle Man-Ying ;
Poh, Ming-Zher ;
Chu, Daniel Wai-Sing ;
Siu, Chung-Wah .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (07)
[6]   Atrial Fibrillation Screening in Nonmetropolitan Areas Using a Telehealth Surveillance System With an Embedded Cloud-Computing Algorithm: Prospective Pilot Study [J].
Chen, Ying-Hsien ;
Hung, Chi-Sheng ;
Huang, Ching-Chang ;
Hung, Yu-Chien ;
Hwang, Juey-Jen ;
Ho, Yi-Lwun .
JMIR MHEALTH AND UHEALTH, 2017, 5 (09)
[7]   mHealth in Cardiovascular Health Care [J].
Chow, Clara K. ;
Ariyarathna, Nilshan ;
Islam, Sheikh Mohammed Shariful ;
Thiagalingam, Aravinda ;
Redfern, Julie .
HEART LUNG AND CIRCULATION, 2016, 25 (08) :802-807
[8]  
Delgoshaei Bahram, 2017, Med J Islam Repub Iran, V31, P113, DOI 10.14196/mjiri.31.113
[9]   Performance of handheld electrocardiogram devices to detect atrial fibrillation in a cardiology and geriatric ward setting [J].
Desteghe, Lien ;
Raymaekers, Zina ;
Lutin, Mark ;
Vijgen, Johan ;
Dilling-Boer, Dagmara ;
Koopman, Pieter ;
Schurmans, Joris ;
Vanduynhoven, Philippe ;
Dendale, Paul ;
Heidbuchel, Hein .
EUROPACE, 2017, 19 (01) :29-39
[10]   Assessment of Remote Heart Rhythm Sampling Using the AliveCor Heart Monitor to Screen for Atrial Fibrillation: The REHEARSE-AF Study [J].
Halcox, Julian P. J. ;
Wareham, Kathie ;
Cardew, Antonia ;
Gilmore, Mark ;
Barry, James P. ;
Phillips, Ceri ;
Gravenor, Michael B. .
CIRCULATION, 2017, 136 (19) :1784-1794