Does intraoperative CT navigation increase the accuracy of pedicle screw placement in pediatric spinal deformity surgery? A systematic review and meta-analysis

被引:33
|
作者
Baldwin, Keith D. [1 ,2 ]
Kadiyala, Manasa [2 ]
Talwar, Divya [1 ]
Sankar, Wudbhav N. [1 ]
Flynn, John Jack M. [1 ]
Anari, Jason B. [1 ]
机构
[1] Childrens Hosp Philadelphia, Div Orthopaed, Philadelphia, PA 19104 USA
[2] Univ Penn, Perelman Sch Med, Philadelphia, PA 19104 USA
关键词
Pediatric Spinal deformity; Navigation; Intraoperative imaging; surgical safety; TOMOGRAPHY-GUIDED NAVIGATION; DOSE O-ARM; COMPUTED-TOMOGRAPHY; IDIOPATHIC SCOLIOSIS; RADIATION-EXPOSURE; OPERATING-ROOM; AORTIC INJURY; PATIENT; FLUOROSCOPY; COMPLICATIONS;
D O I
10.1007/s43390-021-00385-5
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose Although pediatric spinal deformity correction using pedicle screws has a very low rate of complications, the long-term consequences of screw malposition is unknown. CT navigation has been proposed to improve screw accuracy. The aim of this study was to determine whether intraoperative navigation during pedicle screw placement in pediatric scoliosis makes screw placement more accurate. We also examined radiation exposure, operative time blood loss and complications with and without the use of CT navigation in pediatric spinal deformity surgery. Methods A systematic review of the literature was conducted. After screening, 13 articles were qualitatively and quantitatively analyzed to be used for the review. A random effects meta-analysis using REML methodology was employed to compare outcomes of screw accuracy, estimated blood loss, radiation exposure, and surgical duration. Results Screws placed with CT navigation surgery were three times as likely to be deemed "acceptable" compared with screws placed with freehand and 2D fluoroscopy assistance, twice as likely to be "perfect", and only 1/3 as likely to be potentially unsafe (all p value < 0.01). EBL was not significantly different between groups; however, operative time was roughly thirty minutes longer on average. Random effects analysis showed no significant difference in effective dose radiation while using CT navigation (p = 0.06). Conclusion This systematic review of the literature demonstrates that intraoperative navigation results in more accurate pedicle screw placement compared to non-navigated techniques. We found that blood loss was similar in navigated and non-navigated surgery. Operative time was found to be approximately a half hour longer on average in navigated compared to non-navigated surgery. Effective radiation dose trended higher in navigated cases compared to non-navigated cases but did not reach statistical significance.
引用
收藏
页码:19 / 29
页数:11
相关论文
共 50 条
  • [31] Accuracy in navigated percutaneous sacroiliac screw fixation: a systematic review and meta-analysis
    Haveman, R. A.
    Buchmann, L.
    Haefeli, P. C.
    Beeres, F. J. P.
    Babst, R.
    Link, B. - C.
    van de Wall, B. J. M.
    BMC SURGERY, 2025, 25 (01)
  • [32] Computer navigation versus fluoroscopy-guided navigation for thoracic pedicle screw placement: a meta-analysis
    Meng, Xiao-tong
    Guan, Xiao-fei
    Zhang, Hai-long
    He, Shi-sheng
    NEUROSURGICAL REVIEW, 2016, 39 (03) : 385 - 391
  • [33] Risk Factors Associated with Surgical Site Infection in Pediatric Patients Undergoing Spinal Deformity Surgery A Systematic Review and Meta-Analysis
    Matsumoto, Hiroko
    Simhon, Matthew E.
    Campbell, Megan L.
    Vitale, Michael G.
    Larson, Elaine L.
    JBJS REVIEWS, 2020, 8 (03)
  • [34] True accuracy of percutaneous pedicle screw placement in thoracic and lumbar spinal fixation with a CT-based navigation system: Intraoperative and postoperative assessment of 763 percutaneous pedicle screws
    Ouchida, Jun
    Kanemura, Tokumi
    Satake, Kotaro
    Nakashima, Hiroaki
    Segi, Naoki
    Suzuki, Kanae
    Imagama, Shiro
    JOURNAL OF CLINICAL NEUROSCIENCE, 2020, 79 : 1 - 6
  • [35] Accuracy of pedicle screw insertion by AIRO® intraoperative CT in complex spinal deformity assessed by a new classification based on technical complexity of screw insertion
    S. Rajasekaran
    Manindra Bhushan
    Siddharth Aiyer
    Rishi Kanna
    Ajoy Prasad Shetty
    European Spine Journal, 2018, 27 : 2339 - 2347
  • [36] Accuracy of pedicle screw insertion by AIROA® intraoperative CT in complex spinal deformity assessed by a new classification based on technical complexity of screw insertion
    Rajasekaran, S.
    Bhushan, Manindra
    Aiyer, Siddharth
    Kanna, Rishi
    Shetty, Ajoy Prasad
    EUROPEAN SPINE JOURNAL, 2018, 27 (09) : 2339 - 2347
  • [37] Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies
    Nai-Feng Tian
    Qi-Shan Huang
    Ping Zhou
    Yang Zhou
    Rui-Kai Wu
    Yi Lou
    Hua-Zi Xu
    European Spine Journal, 2011, 20 : 846 - 859
  • [38] Comparison of accuracy of pedicle screw placement for adolescent idiopathic scoliosis using freehand fluoroscopic, navigation, and robotic-assisted techniques - a systematic review and bayesian network meta-analysis
    Lajczak, Pawel
    Ayesha, Ayesha
    Jabbar, Rabbia
    Silva, Yasmin Picanco
    Sharma, Eshita
    Sahin, Oguz Kagan
    Lobo, Kaike Eduardo da Silva
    Petry, Iago Nathan Simon
    Ahmed, Aisha Rizwan
    Rocha, Fabio Victor Vieira
    Fagundes, Walter
    Silva, Yan G. M. D.
    NEUROSURGICAL REVIEW, 2025, 48 (01)
  • [39] Safety and Accuracy of Robot-Assisted Cervical Screw Placement: A Systematic Review and Meta-Analysis
    Peng, Jing
    Li, Qiang
    Zhang, Xuejun
    Li, Jiaheng
    Wan, Song
    Yu, Shuangqi
    Chen, Wei
    Chen, Dong
    Ding, Fan
    WORLD NEUROSURGERY, 2024, 181 : 163 - 176
  • [40] Functional outcome of computer-assisted spinal pedicle screw placement: a systematic review and meta-analysis of 23 studies including 5,992 pedicle screws
    Rajeev Verma
    Sonal Krishan
    Kurt Haendlmayer
    A. Mohsen
    European Spine Journal, 2010, 19 : 370 - 375