Breaking the Time Barrier in Kelvin Probe Force Microscopy: Fast Free Force Reconstruction Using the G-Mode Platform

被引:66
作者
Collins, Liam [1 ,2 ]
Ahmadi, Mahshid [3 ]
Wu, Ting [3 ]
Hu, Bin [3 ]
Kalinin, Sergei V. [1 ,2 ]
Jesse, Stephen [1 ,2 ]
机构
[1] Oak Ridge Natl Lab, Ctr Nanophase Mat Sci, Oak Ridge, TN 37831 USA
[2] Oak Ridge Natl Lab, Inst Funct Imaging Mat, Oak Ridge, TN 37831 USA
[3] Univ Tennessee, Dept Mat Sci & Engn, Joint Inst Adv Mat, Knoxville, TN 37996 USA
关键词
atomic force microscopy; ultrafast AFM; time-resolved Kelvin probe force microscopy; ion migration; perovskite solar cells; PHOTOVOLTAIC EFFICIENCY; SINGLE-CRYSTALS; ION MIGRATION; SOLAR-CELLS; LABEL-FREE; PEROVSKITE; RESOLUTION; HYSTERESIS; CHARGE; ACQUISITION;
D O I
10.1021/acsnano.7b02114
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Atomic force microscopy (AFM) offers unparalleled insight into structure and material functionality across nanometer length scales. However, the spatial resolution afforded by the AFM tip is counterpoised by slow detection speeds compared to other common microscopy techniques (e.g., optical, scanning electron microscopy, etc.). In this work, we develop an ultrafast AFM imaging approach allowing direct reconstruction of the tip-sample forces with order of magnitude higher time resolution than is achievable using standard AFM detection methods. Fast free force recovery ((FR)-R-3) overcomes the widely viewed temporal bottleneck in AFM, that is, the mechanical bandwidth of the cantilever, enabling time-resolved imaging at sub bandwidth speeds. We demonstrate quantitative recovery of electrostatic forces with similar to 10 mu s temporal resolution, free from influences of the cantilever ring-down. We further apply the (FR)-R-3 method to Kelvin probe. force microscopy (KPFM) measurements. (FR)-R-3-KPFM is an open loop imaging approach (i.e., no bias feedback), allowing ultrafast surface potential measurements (e.g., <20 mu s) to be performed at regular KPFM scan speeds. (FR)-R-3-KPFM is demonstrated for exploration of ion migration in organometallic halide perovskite materials and shown to allow spatiotemporal imaging of positively charged ion migration under applied electric field, as well as subsequent formation of accumulated charges at the perovskite/electrode interface. In this work, we demonstrate quantitative (FR)-R-3-KPFM measurements however, we fully expect the F3R approach to be valid for all modes of noncontact AFM operation, including noninvasive probing of ultrafast electrical and magnetic dynamics.
引用
收藏
页码:8717 / 8729
页数:13
相关论文
共 50 条
[41]   Measurement of polarization effects in dual-phase ceria-based oxygen permeation membranes using Kelvin probe force microscopy [J].
Neuhaus, Kerstin ;
Schmidt, Christina ;
Fischer, Liudmila ;
Meulenberg, Wilhelm Albert ;
Ran, Ke ;
Mayer, Joachim ;
Baumann, Stefan .
BEILSTEIN JOURNAL OF NANOTECHNOLOGY, 2021, 12 :1380-1391
[42]   Effect of Trapped Charges on Local Potential Measurement of Carbon Nanotubes Using Frequency-Modulation Kelvin-Probe Force Microscopy [J].
Ito, Masanao ;
Hosokawa, Yoshihiro ;
Nishi, Ryuji ;
Miyato, Yuji ;
Kobayashi, Kei ;
Matsushige, Kazumi ;
Yamada, Hirofumi .
E-JOURNAL OF SURFACE SCIENCE AND NANOTECHNOLOGY, 2011, 9 :210-214
[43]   Quasi-free-standing epitaxial graphene on 4H-SiC(0001) as a two-dimensional reference standard for Kelvin Probe Force Microscopy [J].
Ciuk, Tymoteusz ;
Pyrzanowska, Beata ;
Jagiello, Jakub ;
Dobrowolski, Artur ;
Czolak, Dariusz ;
Szary, Maciej J. .
APPLIED SURFACE SCIENCE, 2024, 675
[44]   Measuring the lifetime of silicon nanocrystal solar cell photo-carriers by using Kelvin probe force microscopy and x-ray photoelectron spectroscopy [J].
Borowik, L. ;
Lepage, H. ;
Chevalier, N. ;
Mariolle, D. ;
Renault, O. .
NANOTECHNOLOGY, 2014, 25 (26)
[45]   Effects of Annealing and Light on Co-evaporated Methylammonium Lead Iodide Perovskites using Kelvin Probe Force Microscopy in Ultra-High Vacuum [J].
Gallet, Thibaut ;
Lanzoni, Evandro M. ;
Redinger, Alex .
2019 IEEE 46TH PHOTOVOLTAIC SPECIALISTS CONFERENCE (PVSC), 2019, :1477-1482
[46]   Research Update: Nanoscale surface potential analysis of MoS2 field-effect transistors for biomolecular detection using Kelvin probe force microscopy [J].
Kim, Min Hyung ;
Park, Heekyeong ;
Lee, Hyungbeen ;
Nam, Kihwan ;
Jeong, Seokhwan ;
Omkaram, Inturu ;
Yoon, Dae Sung ;
Lee, Sei Young ;
Kim, Sunkook ;
Lee, Sang Woo .
APL MATERIALS, 2016, 4 (10)
[47]   Comment on "Direct measurement of minority carriers diffusion length using Kelvin probe force microscopy" [Appl. Phys. Lett. 75, 2435 (1999)] [J].
Sabuktagin, Mohammed Shahriar .
APPLIED PHYSICS LETTERS, 2010, 96 (21)
[48]   Characterization of electrical surface properties of mono- and co-cultures of Pseudomonas aeruginosa and methicillin-resistant Staphylococcus aureus using Kelvin probe force microscopy [J].
Birkenhauer, Eric ;
Neethirajan, Suresh .
RSC ADVANCES, 2014, 4 (80) :42432-42440
[49]   Investigation of tip current and normal force measured simultaneously during local oxidation of titanium using dual-mode scanning probe microscopy [J].
Ozcan, Onur ;
Hu, Weihua ;
Sitti, Metin ;
Bain, James ;
Ricketts, David S. .
MICRO & NANO LETTERS, 2014, 9 (05) :332-336
[50]   Reconstruction of high-resolution atomic force microscopy measurements from fast-scan data using a Noise2Noise algorithm [J].
Natinsky, Eva ;
Khan, Ryan M. ;
Cullinan, Michael ;
Dingreville, Remi .
MEASUREMENT, 2024, 227