Calibration for a Multichannel Magnetic Sensor Array of a Magnetospinography System

被引:17
作者
Adachi, Yoshiaki [1 ]
Higuchi, Masanori [1 ]
Oyama, Daisuke [1 ]
Haruta, Yasuhiro [1 ]
Kawabata, Shigenori [2 ]
Uehara, Gen [1 ]
机构
[1] Kanazawa Inst Technol, Kanazawa, Ishikawa 9201331, Japan
[2] Tokyo Med & Dent Univ, Sect Orthopaed & Spinal Surg, Tokyo 1138510, Japan
关键词
Calibration; magnetic sensors; magnetospinography (MSG); superconducting quantum interference devices (SQUIDs);
D O I
10.1109/TMAG.2014.2326869
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A method for calibrating a multichannel superconducting quantum interference device (SQUID) magnetic sensor array of a magnetospinography (MSG) system is proposed. The MSG system detects weak magnetic fields generated by the neural activity of the spinal cord using the array of SQUID sensors. To calibrate 120 SQUID magnetic sensors, we employed an array of precisely machined circular coils to generate fundamental magnetic fields instead of employing Helmholtz coils, which are generally used for the calibration of magnetic sensors. The effective position, orientation, and sensitivity of each SQUID sensor were determined simultaneously by a parametric numerical optimization algorithm. These sensor parameters are essential for improving the accuracy of the magnetic source analysis. Using this method, we could calibrate the magnetic sensors even though they were installed in a non-transparent cryostat. In addition, the shifts from the designed position and orientation of the sensors as well as their variability were evaluated.
引用
收藏
页数:4
相关论文
共 9 条
[1]   Three dimensionally configured SQUID vector gradiometers for biomagnetic measurement [J].
Adachi, Y ;
Kawai, J ;
Miyamoto, M ;
Uehara, G ;
Kawabata, S ;
Okubo, H ;
Fukuoka, Y ;
Komori, H .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2003, 16 (12) :1442-1446
[2]   Magnetospinography: Instruments and Application to Functional Imaging of Spinal Cords [J].
Adachi, Yoshiaki ;
Oyama, Daisuke ;
Kawabata, Shigenori ;
Sekihara, Kensuke ;
Haruta, Yasuhiro ;
Uehara, Gen .
IEICE TRANSACTIONS ON ELECTRONICS, 2013, E96C (03) :326-333
[3]   A PROCEDURE FOR DETERMINING RIGID-BODY TRANSFORMATION PARAMETERS [J].
CHALLIS, JH .
JOURNAL OF BIOMECHANICS, 1995, 28 (06) :733-737
[4]  
HOOKE R, 1961, J ACM, V8, P212, DOI 10.1145/321062.321069
[5]   Magnetoencephalogram systems developed at KIT [J].
Kado, H ;
Higuchi, M ;
Shimogawara, M ;
Haruta, Y ;
Adachi, Y ;
Kawai, J ;
Ogata, H ;
Uehara, G .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) :4057-4062
[6]   A vector fetal magnetocardiogram system with high sensitivity [J].
Kandori, A ;
Miyashita, T ;
Tsukada, K ;
Horigome, H ;
Asaka, M ;
Shigemitsu, S ;
Takahashi, M ;
Terada, Y ;
Mitsui, T ;
Chiba, Y .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (12) :4702-4705
[7]  
Kawakatsu M., 1999, J JPN BIOMAGN BIOELE, V12, P3
[8]   Helmholtz coils for producing uniform magnetic fields [J].
Ruark, AE ;
Peters, MF .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA AND REVIEW OF SCIENTIFIC INSTRUMENTS, 1926, 13 (02) :205-212
[9]  
YOSHIDA T, 1994, PROCEEDINGS OF THE 16TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY - ENGINEERING ADVANCES: NEW OPPORTUNITIES FOR BIOMEDICAL ENGINEERS, PTS 1&2, P171, DOI 10.1109/IEMBS.1994.411802