Cerebral Embolic Protection During Transcatheter Aortic Valve Replacement Significantly Reduces Death and Stroke Compared With Unprotected Procedures

被引:133
作者
Seeger, Julia [1 ]
Gonska, Birgid [1 ]
Otto, Markus [2 ]
Rottbauer, Wolfgang [1 ]
Woehrle, Jochen [1 ]
机构
[1] Univ Ulm, Dept Internal Med 2, Cardiol, Ulm, Germany
[2] Univ Ulm, Dept Neurol, Ulm, Germany
关键词
cerebral embolic protection; outcome; stroke; TAVR; INTERMEDIATE-RISK PATIENTS; SILENT BRAIN INFARCTS; CLINICAL-OUTCOMES; DEFLECTION DEVICE; IMPLANTATION; TRIAL; STENOSIS; METAANALYSIS; TAVI; MRI;
D O I
10.1016/j.jcin.2017.06.037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The aim of this study was to evaluate the impact of cerebral embolic protection on stroke-free survival in patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND Imaging data on cerebral embolic protection devices have demonstrated a significant reduction in number and volume of cerebral lesions. METHODS A total of 802 consecutive patients were enrolled. The Sentinel cerebral embolic protection device (Claret Medical Inc., Santa Rosa, California) was used in 34.9% (n = 280) of consecutive patients. In 65.1% (n = 522) of patients TAVR was performed in the identical setting except without cerebral embolic protection. Neurological follow-up was done within 7 days post-procedure. The primary endpoint was a composite of all-cause mortality or all-stroke according to Valve Academic Research Consortium-2 criteria within 7 days. Propensity score matching was performed to account for possible confounders. RESULTS Both filters of the device were successfully positioned in 280 of 305 (91.8%) consecutive patients. With use of cerebral embolic protection rate of disabling and nondisabling stroke was significantly reduced from 4.6% to 1.4% (p = 0.03; odds ratio: 0.29, 95% confidence interval: 0.10 to 0.93) in the propensity-matched population (n = 560). The primary endpoint occurred significantly less frequently, with 2.1% (n = 6 of 280) in the protected group compared with 6.8% (n = 19 of 280) in the control group (p = 0.01; odds ratio: 0.30; 95% confidence interval: 0.12 to 0.77). In multivariable analysis Society of Thoracic Surgeons score for mortality (p = 0.02) and TAVR without protection (p = 0.02) were independent predictors for the primary endpoint. CONCLUSIONS In patients undergoing TAVR use of a cerebral embolic protection device demonstrated a significant higher rate of stroke-free survival compared with unprotected TAVR. (C) 2017 by the American College of Cardiology Foundation.
引用
收藏
页码:2297 / 2303
页数:7
相关论文
共 34 条
[1]   Anatomical and Procedural Features Associated With Aortic Root Rupture During Balloon-Expandable Transcatheter Aortic Valve Replacement [J].
Barbanti, Marco ;
Yang, Tae-Hyun ;
Cabau, Josep Rodes ;
Tamburino, Corrado ;
Wood, David A. ;
Jilaihawi, Hasan ;
Blanke, Phillip ;
Makkar, Raj R. ;
Latib, Azeem ;
Colombo, Antonio ;
Tarantini, Giuseppe ;
Raju, Rekha ;
Binder, Ronald K. ;
Nguyen, Giang ;
Freeman, Melanie ;
Ribeiro, Henrique B. ;
Kapadia, Samir ;
Min, James ;
Feuchtner, Gudrun ;
Gurtvich, Ronen ;
Alqoofi, Faisal ;
Pelletier, Marc ;
Ussia, Gian Paolo ;
Napodano, Massimo ;
de Brito, Fabio Sandoli ;
Kodali, Susheel ;
Norgaard, Bjarne L. ;
Hansson, Nicolaj C. ;
Pache, Gregor ;
Canovas, Sergio J. ;
Zhang, Hongbin ;
Leon, Martin B. ;
Webb, John G. ;
Leipsic, Jonathon .
CIRCULATION, 2013, 128 (03) :244-253
[2]   Safety and performance of a novel embolic deflection device in patients undergoing transcatheter aortic valve replacement: results from the DEFLECT I study [J].
Baumbach, Andreas ;
Mullen, Michael ;
Brickman, Adam M. ;
Aggarwal, Suneil K. ;
Pietras, Cody G. ;
Forrest, John K. ;
Hildick-Smith, David ;
Meller, Stephanie M. ;
Gambone, Louise ;
den Heijer, Peter ;
Margolis, Pauliina ;
Voros, Szilard ;
Lansky, Alexandra J. .
EUROINTERVENTION, 2015, 11 (01) :75-84
[3]   Silent MRI infarcts and the risk of future stroke - The cardiovascular health study [J].
Bernick, C ;
Kuller, L ;
Dulberg, C ;
Longstreth, WT ;
Manolio, T ;
Beauchamp, N ;
Price, T .
NEUROLOGY, 2001, 57 (07) :1222-1229
[4]   Risk of stroke after transcatheter aortic valve implantation (TAVI): a meta-analysis of 10,037 published patients [J].
Eggebrecht, Holger ;
Schmermund, Axel ;
Voigtlaender, Thomas ;
Kahlert, Philipp ;
Erbel, Raimund ;
Mehta, Rajendra H. .
EUROINTERVENTION, 2012, 8 (01) :129-138
[5]   Transcranial Doppler-detected cerebral embolic load during transcatheter aortic valve implantation† [J].
Erdoes, Gabor ;
Basciani, Reto ;
Huber, Christoph ;
Stortecky, Stefan ;
Wenaweser, Peter ;
Windecker, Stephan ;
Carrel, Thierry ;
Eberle, Balthasar .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 41 (04) :778-784
[6]   Diffusion-weighted MRI determined cerebral embolic infarction following transcatheter aortic valve implantation: assessment of predictive risk factors and the relationship to subsequent health status [J].
Fairbairn, Timothy A. ;
Mather, Adam N. ;
Bijsterveld, Petra ;
Worthy, Gillian ;
Currie, Stuart ;
Goddard, Anthony J. P. ;
Blackman, Daniel J. ;
Plein, Sven ;
Greenwood, John P. .
HEART, 2012, 98 (01) :18-23
[7]   Cerebral Embolic Protection During TAVR A Clinical Event Meta-Analysis [J].
Giustino, Gennaro ;
Sorrentino, Sabato ;
Mehran, Roxana ;
Faggioni, Michela ;
Dangas, George .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (04) :465-466
[8]   Neurological Outcomes With Embolic Protection Devices in Patients Undergoing Transcatheter Aortic Valve Replacement A Systematic Review and Meta-Analysis of Randomized Controlled Trials [J].
Giustino, Gennaro ;
Mehran, Roxana ;
Veltkamp, Roland ;
Faggioni, Michela ;
Baber, Usman ;
Dangas, George D. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (20) :2124-2133
[9]   Microembolism, silent brain infarcts and dementia [J].
Goldberg, I. ;
Auriel, E. ;
Russell, D. ;
Korczyn, A. D. .
JOURNAL OF THE NEUROLOGICAL SCIENCES, 2012, 322 (1-2) :250-253
[10]   Effect of a Cerebral Protection Device on Brain Lesions Following Transcatheter Aortic Valve Implantation in Patients With Severe Aortic Stenosis The CLEAN-TAVI Randomized Clinical Trial [J].
Haussig, Stephan ;
Mangner, Norman ;
Dwyer, Michael G. ;
Lehmkuhl, Lukas ;
Luecke, Christian ;
Woitek, Felix ;
Holzhey, David M. ;
Mohr, Friedrich W. ;
Gutberlet, Matthias ;
Zivadinov, Robert ;
Schuler, Gerhard ;
Linke, Axel .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2016, 316 (06) :592-601