Screening for and validated quantification of phenethylamine-type designer drugs and mescaline in human blood plasma by gas chromatography/mass spectrometry

被引:41
作者
Habrdova, V [1 ]
Peters, FT [1 ]
Theobald, DS [1 ]
Maurer, HH [1 ]
机构
[1] Univ Saarland, Dept Expt & Clin Toxicol, Inst Expt & Clin Pharmacol & Toxicol, D-66421 Homburg, Germany
来源
JOURNAL OF MASS SPECTROMETRY | 2005年 / 40卷 / 06期
关键词
designer drug; phenethylamine; phenylethylamine; GC/MS; blood;
D O I
10.1002/jms.853
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In recent years, several newer designer drugs of the so-called 2C series such as 2C-D, 2C-E, 2C-P, 2C-B, 2C-I, 2C-T-2, and 2C-T-7 have entered the illicit drug market as recreational drugs. Some fatal intoxications involving 2C-T-7 have been reported. Only scarce data have been published about analyses of these substances in human blood and/or plasma. This paper describes a method for screening and simultaneous quantification of the above-mentioned compounds and their analog mescaline in human blood plasma. The analytes were analyzed by gas chromatography/mass spectrometry in the selected-ion monitoring mode, after mixed-mode solid-phase extraction (HCX) and derivatization with heptafluorobutyric anhydride. The method was fully validated according to international guidelines. Validation data for 2C-T-2 and 2C-T-7 were unacceptable. For all other analytes, the method was linear from 5 to 500 mu g/L and the data for accuracy (bias) and precision (coefficient of variation) were within the acceptance limits of +/- 15% and < 15%, respectively (within +/- 20% and < 20% near the limit of quantification of 5 mu g/L). Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:785 / 795
页数:11
相关论文
共 54 条
[1]   Differences in potency and efficacy of a series of phenylisopropylamine/phenylethylamine pairs at 5-HT2A and 5-HT2C receptors [J].
Acuña-Castillo, C ;
Villalobos, C ;
Moya, PR ;
Sáez, P ;
Cassels, BK ;
Huidobro-Toro, J .
BRITISH JOURNAL OF PHARMACOLOGY, 2002, 136 (04) :510-519
[2]  
BASELT RC, 2002, DISPOSTION TOXIC DRU
[3]   Analysis of underivatized amphetamines and related phenethylamines with high-performance liquid chromatography -: Atmospheric pressure chemical ionization mass spectrometry [J].
Bogusz, MJ ;
Krüger, KD ;
Maier, RD .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2000, 24 (02) :77-84
[4]  
BOSMAN IJ, 1999, P 1998 JOINT SOFT TI
[5]  
CALDWELL R, 1997, ANN CLIN BIOCHEM, V26, P430
[6]   Metabolism of the designer drug 4-bromo-2,5-dimethoxyphenethylamine (2C-B) in mice, after acute administration [J].
Carmo, H ;
de Boer, D ;
Remiao, F ;
Carvalho, F ;
dos Reys, LA ;
Bastos, MD .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 811 (02) :143-152
[7]   The bioactivity of 2,5-dimethoxy-4-ethylthiophenethylamine (2C-T-2) and its detection in rat urine by capillary electrophoresis combined with an on-line sample concentration technique [J].
Chiu, YC ;
Chou, SH ;
Liu, JT ;
Lin, CH .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 811 (02) :127-133
[8]   4-Bromo-2,5-dimethoxyphenethylamine (2C-B): a review of the public domain literature [J].
Cole, MD ;
Lea, C ;
Oxley, N .
SCIENCE & JUSTICE, 2002, 42 (04) :223-224
[9]   Postmortem identification and quantitation of 2,5-dimethoxy-4-n-propylthiophenethylamine using GG-MSD and GC-NPD [J].
Curtis, B ;
Kemp, P ;
Harty, L ;
Choi, C ;
Christensen, D .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2003, 27 (07) :493-498
[10]   A new trend in drugs-of-abuse; the 2C-series of phenethylamine designer drugs [J].
de Boer, D ;
Bosman, I .
PHARMACY WORLD & SCIENCE, 2004, 26 (02) :110-113