Solutions for enhancement of energy and exergy efficiencies in air handling units

被引:86
作者
Liu, Wanli [1 ,2 ]
Kalbasi, Rasool [3 ]
Afrand, Masoud [4 ,5 ]
机构
[1] China Univ Min & Technol, Sch Mech & Elect Engn, Xuzhou 210008, Jiangsu, Peoples R China
[2] China Univ Min & Technol, Jiangsu Collaborat Innovat Ctr Intelligent Min Eq, Xuzhou 210008, Jiangsu, Peoples R China
[3] Islamic Azad Univ, Dept Mech Engn, Najafabad Branch, Najafabad, Iran
[4] Ton Duc Thang Univ, Adv Inst Mat Sci, Lab Magnetism & Magnet Mat, Ho Chi Minh City, Vietnam
[5] Ton Duc Thang Univ, Fac Appl Sci, Ho Chi Minh City, Vietnam
关键词
Air handling unit; Exergy analysis; Irreversibility; Air-to-air heat exchanger; Cost saving; MODEL-PREDICTIVE CONTROL; HEAT-RECOVERY; HVAC SYSTEMS; MULTIOBJECTIVE OPTIMIZATION; PERFORMANCE; TECHNOLOGIES; VENTILATION; STRATEGIES; DESIGN; PUMP;
D O I
10.1016/j.jclepro.2020.120565
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, five layouts of using air-to-air heat exchangers (AAHE) were added in the Air Handling Unit (AHU) to diminish the cooling and heating coils energy usage through the energetic and exergetic analysis approach. In the first, second, and third techniques, the main focus is on cooling coil energy usage reduction. In the fourth and fifth layouts, new designs of using two AAHEs (i.e., primary and secondary units) have been incorporated to diminish simultaneously the energy demand of coils. The results showed if the objective function is defined to have the least cooling coil power, the fourth layout, and if the objective function is the lowest heating coil load, the fifth layout is recommended. In all layouts, installation of the AAHE reduced the irreversibility. In the best layout, AHU energy demand diminished by 23.68% which consequently improved the first law efficiency by 31.29%. Similarly, total exergy losses reduced by 26.58% and the second law efficiency improved by 11.79%. Calculations on cost analysis revealed that the least payback time and highest cost saving referred to first and fourth layouts, respectively. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:16
相关论文
共 55 条
[1]   Artificial neural network (ANN) based model predictive control (MPC) and optimization of HVAC systems: A state of the art review and case study of a residential HVAC system [J].
Afram, Abdul ;
Janabi-Sharifi, Farrokh ;
Fung, Alan S. ;
Raahemifar, Kaamran .
ENERGY AND BUILDINGS, 2017, 141 :96-113
[2]   Exergy, exergoenvironmental and exergoeconomic evaluation of a heat pump-integrated wall heating system [J].
Akbulut, Ugur ;
Utlu, Zafer ;
Kincay, Olcay .
ENERGY, 2016, 107 :502-522
[3]   CFD simulation of air to air enthalpy heat exchanger [J].
Al-Waked, Rafat ;
Nasif, Mohammad Shakir ;
Morrison, Graham ;
Behnia, Masud .
ENERGY CONVERSION AND MANAGEMENT, 2013, 74 :377-385
[4]  
[Anonymous], MARK INS WWW DOC
[5]   A novel enhanced exergy method in analyzing HVAC system using soft computing approaches: A case study on mushroom growing hall [J].
Ardabili, Sina Faizollahzadeh ;
Najafi, Bahman ;
Ghaebi, Hadi ;
Shamshirband, Shahaboddin ;
Mostafaeipour, Ali .
JOURNAL OF BUILDING ENGINEERING, 2017, 13 :309-318
[6]  
ASHRAE A.H., 2015, AM SOC HEATING REFRI
[7]   Performance and sustainability assessment of energy options for building HVAC applications [J].
Balta, M. Tolga ;
Dincer, Ibrahim ;
Hepbasli, Arif .
ENERGY AND BUILDINGS, 2010, 42 (08) :1320-1328
[8]   Buildings energy use and human thermal comfort according to energy and exergy approach [J].
Buyak, N. A. ;
Deshko, V. I. ;
Sukhodub, I. O. .
ENERGY AND BUILDINGS, 2017, 146 :172-181
[9]   Enhanced thermodynamic assessments of the novel desiccant air cooling system for sustainable energy future [J].
Caliskan, Hakan ;
Lee, Dae-Young ;
Hong, Hiki .
JOURNAL OF CLEANER PRODUCTION, 2019, 211 :213-221
[10]   Exergy-based ecological optimization for a four-temperature-level absorption heat pump with heat resistance, heat leakage and internal irreversibility [J].
Chen, Lingen ;
Ge, Yanlin ;
Qin, Xiaoyong ;
Xie, Zhihui .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 129 :855-861