Outcomes of refractive error correction in pseudophakic patients using a sulcus piggyback intraocular lens

被引:8
作者
Levinger, Eliya [1 ,2 ]
Mimouni, Michael [3 ,4 ]
Finkelman, Yaron [1 ,2 ]
Yatziv, Yossi [1 ,2 ]
Shahar, Jonathan [1 ,2 ]
Trivizki, Omer [1 ,2 ]
机构
[1] Tel Aviv Med Ctr & Sch Med, Dept Ophthalmol, Tel Aviv, Israel
[2] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
[3] Rambam Hlth Care Campus, Dept Ophthalmol, IL-3109601 Haifa, Israel
[4] Technion Israel Inst Technol, Ruth & Bruce Rappaport Fac Med, Haifa, Israel
关键词
Piggyback; Sulcoflexs; sulcus; intraocular; lens; GLAUCOMA; EXCHANGE;
D O I
10.1177/1120672120903560
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this study was to assess the results of a sulcus intraocular lens (Sulcoflex) for pseudophakic refractive errors following phacoemulsification cataract surgery. Methods: This retrospective clinical observational cohort study included consecutive eyes in which a Sulcoflex was implanted. Uncorrected distance visual acuity and corrected distance visual acuity as well as refractive outcomes were assessed. The minimum follow-up time required for inclusion was 3 months. Results: In total, 15 eyes (n = 15) were evaluated. The mean follow-up was 14 months (range: 3-18 months). The Sulcoflex aspheric (653L) was implanted in 13 eyes and the Sulcoflex toric (653T) in two eyes. The preoperative mean logMAR (Snellen) uncorrected distance visual acuity and corrected distance visual acuity were 0.88 (20/150) and 0.27 (20/40), respectively. The postoperative mean logMAR (Snellen) corrected distance visual acuity was 0.15 (20/30). The preoperative mean spherical equivalent was -0.22 +/- 5.95 D and the postoperative mean spherical equivalent was -1.59 +/- 1.45 D. There was a significant and strong correlation (r = 0.64, p < 0.001) between the attempted and the achieved spherical equivalent. Conclusion: The Sulcoflex is a safe and viable option for patients with residual refractive error following cataract surgery.
引用
收藏
页码:422 / 426
页数:5
相关论文
共 40 条
  • [31] Outcomes of Descemet Stripping Automated Endothelial Keratoplasty in Patients With an Anterior Chamber Versus Posterior Chamber Intraocular Lens
    Shpitzer, Sagi Arieh
    Rosenblatt, Amir
    Bahar, Irit
    CORNEA, 2014, 33 (07) : 686 - 690
  • [32] A prospective pilot study using a low power piggy-back toric implantable Collamer lens to correct residual refractive error after multifocal IOL implantation
    Duncker, Gernot I. W.
    Sasse, Anna C.
    Duncker, Tobias
    CLINICAL OPHTHALMOLOGY, 2019, 13 : 1689 - 1702
  • [33] Premium IOL's in glaucoma patients: Guidelines from the French Glaucoma Society (SFG) and the Society of the French Intraocular Lens and Refractive Surgery Association
    Blumen, E.
    Denoyer, A.
    Grise-Dulac, A.
    Rousseau, A.
    Schweitzer, C.
    Rozot, P.
    Aptel, F.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2025, 48 (03):
  • [34] Clinical Outcomes of Sequential Intrastromal Corneal Ring Segments and an Extended Range of Vision Intraocular Lens Implantation in Patients with Keratoconus and Cataract
    Lisa, C.
    Zaldivar, R.
    Fernandez-Vega Cueto, A.
    Sanchez-Avila, R. M.
    Madrid-Costa, D.
    Alfonso, J. F.
    JOURNAL OF OPHTHALMOLOGY, 2018, 2018
  • [35] Outcomes of a non-diffractive extended depth of focus intraocular lens in patients with well-controlled glaucoma and ocular hypertension
    Liu, Jia-Ru
    Szigiato, Andrei-Alexandru
    Harasymowycz, Paul
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2025, 18 (01) : 79 - 85
  • [36] Prospective analysis of visual outcomes using apodized, diffractive multifocal intraocular lenses following phacoemulsification for cataract or clear lens extraction
    Altaie, Rasha
    Ring, C. Peter
    Morarji, Jasha
    Patel, Dipika V.
    McGhee, Charles N. J.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 (02) : 148 - 154
  • [37] Intereye Symmetry of 24-Hour Intraocular Pressure-related Patterns in Untreated Glaucoma Patients Using a Contact Lens Sensor
    Mansouri, Kaweh
    Gillmann, Kevin
    JOURNAL OF GLAUCOMA, 2020, 29 (08) : 666 - 670
  • [38] Visual Outcomes, Spectacle Independence, and Patient-Reported Satisfaction of the Vivity Extended Range of Vision Intraocular Lens in Patients with Early Glaucoma: An Observational Comparative Study
    Kerr, Nathan Mitchell
    Moshegov, Sophia
    Lim, Samantha
    Simos, Maria
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 1515 - 1523
  • [39] Continuous intraocular pressure variations following positional transitions in normal subjects and open angle glaucoma patients using a contact lens sensor system
    Zhang, Yuning
    Yang, Wenxin
    Chen, Zidong
    Zhang, Xinyi
    Or, Ping Wai
    Lee, Ching Hymn Christopher
    Karunaratne, Isuru Kaweendra
    Xu, Yunzhi
    Liu, Pingping
    Chong, Iok Tong
    Qin, Zhen
    Lam, David C. C.
    Yu, Minbin
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, : 1061 - 1070
  • [40] Circadian Fluctuation Changes in Intraocular Pressure Measured Using a Contact Lens Sensor in Patients with Glaucoma after the Adjunctive Administration of Ripasudil: A Prospective Study
    Huang, Shih-Kung
    Ishii, Mai
    Mizuki, Yuki
    Kawagoe, Tatukata
    Takeuchi, Masaki
    Nomura, Eiichi
    Mizuki, Nobuhisa
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (05):