Ultrasonic instrumentation system for Liquefied Petroleum Gas level monitoring

被引:24
作者
Zakaria, Zainal [1 ]
Idroas, Mariani [1 ]
Samsuri, Ariffin [2 ]
Adam, Ahmad Akif [1 ]
机构
[1] Univ Teknol Malaysia, Dept Energy Engn, Skudai, Johor, Malaysia
[2] Univ Teknol Malaysia, Dept Petr Engn, Skudai, Johor, Malaysia
关键词
Liquefied Petroleum Gas; Ultrasonic; Level monitoring; Non-invasive; Lamb wave; LIQUID-LEVEL;
D O I
10.1016/j.jngse.2017.05.006
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Liquefied Petroleum Gas (LPG) is commonly stored in a highly pressurized cylinder tank, where its liquid level needs to be measured accurately for a safety reason. Currently, the level of LPG is measured using a weighing scale. This approach has been constructed to facilitate the process of LPG level measurement inside a cylinder tank. In this research, a new method is developed by using a non-invasive ultrasonic instrumentation system for monitoring LPG level in a 14 kilogram cylinder. The instrumentation system was integrated with the designed experimental rig. Module ultrasonic sensors Truma. LC-V1.15 were attached vertically outside of the cylinder wall on a sensor holder of the experimental rig. The ultrasonic sensors emit the ultrasonic signals and the signals will then propagate through the cylinder wall. The reflected signal was recorded again by the ultrasonic sensors. The reflection of the ultrasonic signal depends on the type of the medium's impedance. The generated signals from the transceiver type of sensors were sent to the Pico Scope Data Acquisition System (DAQ) for data reading. The output voltage signals were processed by the computational data process system, giving a result of the LPG liquid level inside the cylinder. An image of the liquid level in the cylinder was constructed using javascript based programming. The image showed the liquid level in percentage value and a html software was used as the interface in this program. The,developed instrumentation system was able to detect the level of LPG in the cylinder. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:428 / 435
页数:8
相关论文
共 14 条
[1]  
[Anonymous], P IM SIGN PROC CISP
[2]  
[Anonymous], 2014, INT J INNOVATIVE RES
[3]  
[Anonymous], P COMP APPL SYST MOD
[4]  
[Anonymous], ULTRASOUND
[5]  
[Anonymous], INT J ENG BUS ENTERP
[6]  
[Anonymous], INT J RECENT RES APP
[7]  
[Anonymous], AC PROP LIQ GAS SOL
[8]   FREE-VIBRATION OF A CANTILEVER TUBE PARTIALLY FILLED WITH LIQUID [J].
CHAN, KT ;
ZHANG, JZ .
JOURNAL OF SOUND AND VIBRATION, 1995, 182 (02) :185-190
[9]  
Cheeke JDN, 2012, Fundamentals and applications of ultrasonic waves, V2nd
[10]   Ultrasonic system for accurate distance measurement in the air [J].
Licznerski, Tomasz J. ;
Jaronski, Jaroslaw ;
Kosz, Dariusz .
ULTRASONICS, 2011, 51 (08) :960-965