Comparison of diagnosis of cracked tooth using contrast-enhanced CBCT and micro-CT

被引:6
作者
Hu, ZiYang [1 ]
Wang, TieMei [1 ]
Pan, Xiao [1 ]
Cao, DanTong [1 ]
Liang, JiaHao [1 ]
Gao, AnTian [1 ]
Xie, Xin [2 ]
Xu, Shi [3 ]
Miao, LeiYing [3 ]
Lin, ZiTong [1 ]
机构
[1] Nanjing Univ, Nanjing Stomatol Hosp, Dept Dentomaxillofacial Radiol, Med Sch, Nanjing, Peoples R China
[2] Third Peoples Hosp Danyang City, Dept Stomatol, Danyang, Peoples R China
[3] Nanjing Univ, Nanjing Stomatol Hosp, Dept Endodont, Med Sch, Nanjing, Peoples R China
关键词
Cracked tooth; Cone-beam CT; Micro-CT; Sodium iodide; Dimethyl sulfoxide; OPTICAL COHERENCE TOMOGRAPHY; BEAM COMPUTED-TOMOGRAPHY; VERTICAL ROOT FRACTURES; PERIAPICAL RADIOGRAPHY; ENAMEL CRACKS; TEETH; VISCOSITY; ACCURACY;
D O I
10.1259/dmfr.20210003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the diagnostic accuracy using sodium iodide (NaI) and dimethyl sulfoxide (DMSO) as contrast agent in cone beam computed tomography (CBCT) scanning, and compare this with micro-CT. Methods: 18 teeth were cracked artificially by soaking them cyclically in liquid nitrogen and hot water. After pre-treatment with artificial saliva, the teeth were scanned in four modes: CBCT routine scanning without contrast agent (RS); CBCT with meglumine diatrizoate (MD) as contrast agent (ES1); CBCT with NaI + DMSO as contrast agent (ES2); and micro-CT (mCT). The number of crack lines was evaluated in all four modes. Depth of crack lines and number of cracks presented from the occlusal surface to the pulp cavity (Np) in ES2 and micro-CT images were evaluated. Results: There were 63 crack lines in all 18 teeth. 45 crack lines were visible on ES2 images as against four on the RS and ES1 images (p<0.05) and 37 on micro-CT images (p>0.05). Further, 34 crack lines could be observed on both ES2 and micro-CT images, and the average depth presented on ES2 images was 4.56 +/- 0.88 mm and 3.89 +/- 1.08 mm on micro--CT images (p<0.05). More crack lines could be detected from the occlusal surface to the pulp cavity on ES2 images than on micro-CT images (22 vs 11). Conclusion: CBCT with NaI +DMSO as the contrast agent was equivalent to micro-CT for number of crack lines and better for depth of crack lines. NaI + DMSO could be a potential CBCT contrast agent to improve diagnostic accuracy for cracked tooth.
引用
收藏
页数:8
相关论文
共 32 条
[1]  
Aboud Lilian Rachel de Lima, 2018, Braz. Dent. J., V29, P530, DOI 10.1590/0103-6440201802134
[2]   Managing incomplete tooth fractures [J].
Ailor, JE .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2000, 131 (08) :1168-1174
[3]  
Amal A.S.S., 2015, PREPARATION ARTIFICI
[4]   Fracture Necrosis: Diagnosis, Prognosis Assessment, and Treatment Recommendations [J].
Berman, Louis H. ;
Kuttler, Sergio .
JOURNAL OF ENDODONTICS, 2010, 36 (03) :442-446
[5]   A comparison of cone beam computed tomography and periapical radiography for the detection of vertical root fractures in nonendodontically treated teeth [J].
Brady, E. ;
Mannocci, F. ;
Brown, J. ;
Wilson, R. ;
Patel, S. .
INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (08) :735-746
[6]  
Brunton L., 2010, Goodman Gilman's The Pharmacological Basis of Therapeutics, DOI DOI 10.1036/0071422803
[7]   Comparing the In Vivo Diagnostic Accuracy of Digital Periapical Radiography with Cone-beam Computed Tomography for the Detection of Vertical Root Fracture [J].
Chavda, Rajesh ;
Mannocci, Francesco ;
Andiappan, Manoharan ;
Patel, Shanon .
JOURNAL OF ENDODONTICS, 2014, 40 (10) :1524-1529
[8]   Predicting extension of cracks to the root from the dimensions in the crown A preliminary in vitro study [J].
Chen, Min ;
Fu, Kaiyu ;
Qiao, Feng ;
Zhang, Xu ;
Fan, Yi ;
Wang, Lijun ;
Li, Peng ;
Wu, Zhou ;
Wu, Ligeng .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2017, 148 (10) :737-742
[9]  
Clark David J, 2003, J Esthet Restor Dent, V15, P391, DOI 10.1111/j.1708-8240.2003.tb00963.x
[10]   Ultrasound crack detection in a simulated human tooth [J].
Culjat, MO ;
Singh, RS ;
Brown, ER ;
Neurgaonkar, RR ;
Yoon, DC ;
White, SN .
DENTOMAXILLOFACIAL RADIOLOGY, 2005, 34 (02) :80-85