Effect of power density of curing unit, exposure duration, and light guide distance on composite depth of cure

被引:71
|
作者
Lindberg, A
Peutzfeldt, A
van Dijken, JWV [1 ]
机构
[1] Umea Univ, Sch Dent, Dept Odontol, S-90187 Umea, Sweden
[2] Publ Dent Hlth Clin, Skelleftea, Sweden
[3] Univ Copenhagen, Sch Dent, Dept Dent Mat, Copenhagen, Denmark
关键词
halogen; hardness; irradiance; LED; polymerization;
D O I
10.1007/s00784-005-0312-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This in vitro study compared the depth of cure obtained with six quartz tungsten halogen and light-emitting diode curing units at different exposure times and light tip-resin composite distances. Resin composite specimens (Tetric Ceram, A3; diameter 4 mm, height 6 mm) were exposed from 0-, 3-, and 6-mm distance. The curing units (200-700 MW/cm(2)) were used for standard (20 and 40 s), pulse-delay mode (initial exposure of 3 s at 200 mW/cm(2), followed by a resting period of 3 min and a final exposure of 10 or 30 s at 600 MW/cm(2)), or soft-start curing (40 s; exponential ramping). Curing depth was determined by measurement of Wallace hardness for each half millimeter starting at 0.5 min from the top surface. For each specimen, a mean H-W value was calculated from the H-W values determined at the depths of 2.0 mm and less (0.5, 1.0, 1.5, and 2.0 min, respectively). The depth of cure for each specimen was found by determining the greatest depth before an H-W value exceeding the minimal H-W value by 25% occurred. For all curing units, an increase in exposure time led to significantly higher depth of cure. Increasing the light tip-resin composite distance significantly reduced the depth of cure. With a light tip-resin composite distance of 6 min, median values of depth of cure varied between 2.0 and 3.5 min following a 20-s (or 3+10 s) exposure and between 3.0 and 4.5 mm following a 40-s (or 3+30 s) exposure. The composite situated above the depth of cure value cured equally well with all curing units. At both exposure times, Luxomax resulted in the significantly lowest depth of cure, and Astralis 7 yielded significantly higher depth. At both exposure times, a significant linear correlation was found between the determined power densities of the curing units and the pooled depth of cure values obtained. It seems that for the resin composite tested, the recommended exposure time of 40 s per 2-mm increment may be reduced to 20 s, or that increments may be increased from 2 to 3.5 mm. It may be that the absolute values of depth of cure found are material specific, but we believe that the relationships found between curing units, between exposure times, and between light guide distances are universal.
引用
收藏
页码:71 / 76
页数:6
相关论文
共 18 条
  • [1] Effect of power density of curing unit, exposure duration, and light guide distance on composite depth of cure
    Anders Lindberg
    Anne Peutzfeldt
    Jan W. V. van Dijken
    Clinical Oral Investigations, 2005, 9 : 71 - 76
  • [2] Curing characteristics of a composite. Part 2: The effect of curing configuration on depth and distribution of cure
    Erickson, Robert L.
    Barkmeier, Wayne W.
    DENTAL MATERIALS, 2014, 30 (06) : E134 - E145
  • [3] Effects of extending duration of exposure to curing light and different measurement methods on depth-of-cure analyses of conventional and bulk-fill composites
    de Cassia Romano, Beatriz
    Soto-Montero, Jorge
    Rueggeberg, Frederick A.
    Giannini, Marcelo
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2020, 128 (04) : 336 - 344
  • [4] Effect of light-curing distance and curing time on composite microflexural strength
    Al-Zain, Afnan O.
    Platt, Jeffrey A.
    DENTAL MATERIALS JOURNAL, 2021, 40 (01) : 202 - 208
  • [5] Effect of duration and infection control barriers of light curing unit on hardness of Bulk Fill composite resin
    He, Xinmin
    Zhang, Denghui
    Deng, Shuli
    PEERJ, 2024, 12
  • [6] Effect of duration and infection control barriers of light curing unit on hardness of Bulk Fill composite resin
    He, Xinmin
    Zhang, Denghui
    Deng, Shuli
    PEERJ COMPUTER SCIENCE, 2024, 12
  • [7] Curing characteristics of a composite - Part 1: Cure depth relationship to conversion, hardness and radiant exposure
    Erickson, Robert L.
    Barkmeier, Wayne W.
    Halvorson, Rolf H.
    DENTAL MATERIALS, 2014, 30 (06) : E125 - E133
  • [8] Photomitiator dependent composite depth of cure and Knoop hardness with halogen and LED light curing units
    Uhl, A
    Mills, RW
    Jandt, KD
    BIOMATERIALS, 2003, 24 (10) : 1787 - 1795
  • [9] Effect of Curing Light Barriers and Light Types on Radiant Exposure and Composite Conversion
    Sword, Rhoda Joyner
    Uyen Ngoc Do
    Chang, Jonathan Hu
    Rueggeberg, Frederick Allen
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2016, 28 (01) : 29 - 42
  • [10] Visible-light curing units: Correlation between depth of cure and distance between exit window and resin surface
    Hansen, EK
    Asmussen, E
    ACTA ODONTOLOGICA SCANDINAVICA, 1997, 55 (03) : 162 - 166