Efficacy of the RADPAD Protection Drape in Reducing Operators' Radiation Exposure in the Catheterization Laboratory: A Sham-Controlled Randomized Trial

被引:48
|
作者
Vlastra, Wieneke [1 ]
Delewi, Ronak [1 ]
Sjauw, Krischan D. [1 ]
Beijk, Marcel A. [1 ]
Claessen, Bimmer E. [1 ]
Streekstra, Geert J. [2 ]
Bekker, Robbert J. [1 ]
van Hattum, Juliette C. [1 ]
Wykrzykowska, Joanna J. [1 ]
Vis, Marije M. [1 ]
Koch, Karel T. [1 ]
de Winter, Robbert J. [1 ]
Piek, Jan J. [1 ]
Henriques, Jose P. S. [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Heart Ctr, Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Biomed Engn & Phys & Radiol & Nucl Med, Amsterdam, Netherlands
关键词
fluoroscopy; percutaneous coronary intervention; radiation; radiation protection; risk; PERCUTANEOUS CORONARY INTERVENTIONS; DOSE REDUCTION; RADIOLOGY; SHIELD; CARDIOLOGISTS; ANGIOGRAPHY; PATIENT; TUMORS; STAFF; RISK;
D O I
10.1161/CIRCINTERVENTIONS.117.006058
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Interventional cardiologists are increasingly exposed to radiation-induced diseases like cataract and the stochastic risk of left-sided brain tumors. The RADPAD is a sterile, disposable, lead-free shield placed on the patient with the aim to minimize operator-received scatter radiation. The objective of the trial was to examine the RADPAD's efficacy in a real-world situation. Methods and Results In the current, double-blind, sham-controlled, all-comer trial, patients undergoing diagnostic catheterization or percutaneous coronary interventions were randomized in a 1:1:1 ratio to a radiation absorbing shield (RADPAD), standard treatment (NOPAD), or a sham shield (SHAMPAD). The sham shield allowed testing for shield-induced radiation behavior. The primary outcome was the difference in relative exposure of the primary operator between the RADPAD and NOPAD arms and was defined as the ratio between operator's exposure (E in mu Sv) and patient exposure (dose area product in mGycm(2)), measured per procedure. A total of 766 consecutive coronary procedures were randomized to the use of RADPAD (N=255), NOPAD (N=255), or SHAMPAD (N=256). The use of RADPAD was associated with a 20% reduction in relative operator exposure compared with that of NOPAD (P=0.01) and a 44% relative exposure reduction compared with the use of a SHAMPAD (P<0.001). Use of the SHAMPAD was associated with a 43% higher relative radiation exposure than procedures with NOPAD (P=0.009). Conclusions In clinical daily practice, the standard use of the RADPAD radiation shield reduced operator radiation exposure compared with procedures with NOPAD or SHAMPAD. This study supports the routine use of RADPAD in the catheterization laboratory. Clinical Trial Registration URL: https://www.clinicaltrials.gov. Unique identifier: NCT03139968.
引用
收藏
页数:7
相关论文
共 11 条
  • [1] Assessing the Efficacy of RADPAD Protection Drape in Reducing Radiation Exposure to Operators in the Cardiac Catheterization Laboratory: A Systematic Review and MetaAnalysis
    Bahar, Abdul Rasheed
    Khanal, Resha
    Hamza, Mohammad
    Goru, Rohit K.
    Shafiq, Aimen
    Haider, Mobeen Z.
    Basit, Salman Abdul
    Bahar, Yasemin
    Umer, Ahmed Muaaz
    Sattar, Yasar
    Alraies, M. Chadi
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)
  • [2] Efficacy of RADPAD protection drape in reducing radiation exposure in the catheterization laboratory-First Indian study
    Shah, Pujan
    Khanna, Roopali
    Kapoor, Aditya
    Goel, Pravin K.
    INDIAN HEART JOURNAL, 2018, 70 : S265 - S268
  • [3] Efficacy of RADPAD® protection drape in reducing radiation exposure to the primary operator during Transcatheter Aortic Valve Implantation (TAVI)
    Sharma, Divyesh
    Ramsewak, Adesh
    Manoharan, Ganesh
    Spence, Mark S.
    MINERVA CARDIOANGIOLOGICA, 2016, 64 (01): : 41 - 46
  • [4] Efficacy of MAVIG X-Ray Protective Drapes in Reducing Operator Radiation Dose in the Cardiac Catheterization Laboratory A Randomized Controlled Trial
    McCutcheon, Keir
    Vanhaverbeke, Maarten
    Pauwels, Ruben
    Dabin, Jeremie
    Schoonjans, Werner
    Bennett, Johan
    Adriaenssens, Tom
    Dubois, Christophe
    Sinnaeve, Peter
    Desmet, Walter
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (11) : E009627
  • [5] A Double-Blind, Randomized, Sham-Controlled Trial of the Effect of a Radiation-Attenuating Drape on Radiation Exposure to Endoscopy Staff During ERCP
    Muniraj, Thiruvengadam
    Aslanian, Harry R.
    Laine, Loren
    Farrell, James
    Ciarleglio, Maria M.
    Deng, Yanhong
    Ho, Henry
    Jamidar, Priya A.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2015, 110 (05) : 690 - 696
  • [6] Efficacy and User Experience of a Novel X-Ray Shield on Operator Radiation Exposure During Cardiac Catheterization: A Randomized Controlled Trial
    Davidsen, Cedric
    Ytre-Hauge, Kristian
    Samnoy, Andreas Tefre
    Vikenes, Kjell
    Lancellotti, Patrizio
    Tuseth, Vegard
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (12) : 745 - 753
  • [7] A Randomized, Double-blind, Sham-controlled Trial Comparing Two Screening Devices for Radiation Contamination
    Salen, Philip
    Porter, Mathew
    Watts, David
    Stoltzfus, Jill
    Lynch, Alan
    Michaelis, Christopher
    Melanson, Scott
    ACADEMIC EMERGENCY MEDICINE, 2010, 17 (09) : 1020 - 1023
  • [8] Randomized Controlled Trial of Radiation Protection With a Patient Lead Shield and a Novel, Nonlead Surgical Cap for Operators Performing Coronary Angiography or Intervention
    Alazzoni, Ashraf
    Gordon, Chris L.
    Syed, Jaffer
    Natarajan, Madhu K.
    Rokoss, Michael
    Schwalm, Jon-David
    Mehta, Shamir R.
    Sheth, Tej
    Valettas, Nicholas
    Velianou, James
    Pandie, Shaheen
    Al Khdair, Darar
    Tsang, Michael
    Meeks, Brandi
    Colbran, Kiersten
    Waller, Ed
    Lee, Shun Fu
    Marsden, Tamara
    Jolly, Sanjit S.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (08)
  • [9] Reducing Radiation Exposure in Lumbar Transforaminal Epidural Steroid Injections with Pulsed Fluoroscopy: A Randomized, Double-blind, Controlled Clinical Trial
    Braun, Edward
    Sack, Andrew M.
    Sayed, Dawood
    Manion, Smith
    Hamm, Brian
    Brimacombe, Michael
    Tollette, Michael
    Khan, Talal W.
    Orr, Walter
    Nicol, Andrea
    PAIN PHYSICIAN, 2018, 21 (01) : 53 - 60
  • [10] Efficacy and safety of daily home-based transcranial direct current stimulation as adjunct treatment for bipolar depressive episodes: Double-blind sham-controlled randomized clinical trial
    Lee, Jangwon
    Lee, Chan Woo
    Jang, Yoonjeong
    You, Ji Seon
    Park, Yun Seong
    Ji, Eunjeong
    Yu, Hyeona
    Oh, Sunghee
    Ryoo, Hyun A.
    Cho, Nayoung
    Park, Ji Yoon
    Yoon, Joohyun
    Baek, Ji Hyun
    Park, Hye Youn
    Ha, Tae Hyon
    Myung, Woojae
    FRONTIERS IN PSYCHIATRY, 2022, 13