Performance assessment of a low grade waste heat driven organic flash cycle (OFC) with ejector

被引:61
作者
Mondal, Subha [1 ]
Alam, Shahbaz [1 ]
De, Sudipta [2 ]
机构
[1] Aliah Univ, Dept Mech Engn, Kolkata 700156, India
[2] Jadavpur Univ, Dept Mech Engn, Kolkata 700032, India
关键词
Area utilization temperature indicator; Ejector; Entrainment ratio; OFC; Waste heat recovery; Pinch limitation; REFRIGERATION CYCLE; RANKINE-CYCLE; COMBINED POWER; ECONOMIC-ANALYSIS; WORKING FLUID; RECOVERY; SYSTEM; GAS; INTERMEDIATE; EFFICIENCIES;
D O I
10.1016/j.energy.2018.08.160
中图分类号
O414.1 [热力学];
学科分类号
摘要
Organic flash cycle (OFC) appears as one of the preferable options for waste heat recovery due to better matching of temperature profiles in the heat recovery unit (HRU). However, efficiency of an OFC reduces appreciably due to higher irreversibilities of the high pressure and the low pressure throttling devices. In the present study, to overcome this drawback low pressure throttle valve of the conventional OFC is replaced by an ejector. The saturated liquid stream exiting the vapour separator is accelerated in the nozzle of the ejector as primary flow and the stream coming out of the turbine is entrained in the ejector as secondary flow. Due to the presence of the ejector, the dry saturated vapour leaving the vapour separator of the OFC can be expanded in the turbine to a pressure which is lower than the specified condenser pressure. The turbine exit pressure is such that total working fluid mass exiting the diffuser of the ejector is at condenser pressure. OFC with ejector yields an increment of about 9.50% in both first law efficiency as well as power output compared to that of the conventional OFC. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:849 / 862
页数:14
相关论文
共 36 条
[11]   Thermodynamic and thermoeconomic analysis and optimization of a novel combined cooling and power (CCP) cycle by integrating of ejector refrigeration and Kalina cycles [J].
Ghaebi, Hadi ;
Parikhani, Towhid ;
Rostamzadeh, Hadi ;
Farhang, Behzad .
ENERGY, 2017, 139 :262-276
[12]   Increased power production through enhancements to the Organic Flash Cycle (OFC) [J].
Ho, Tony ;
Mao, Samuel S. ;
Greif, Ralph .
ENERGY, 2012, 45 (01) :686-695
[13]   Comparison of the Organic Flash Cycle (OFC) to other advanced vapor cycles for intermediate and high temperature waste heat reclamation and solar thermal energy [J].
Ho, Tony ;
Mao, Samuel S. ;
Greif, Ralph .
ENERGY, 2012, 42 (01) :213-223
[14]  
International energy outlook (IEO), 2017, INT EN OUTL IEO
[15]  
KEENAN JH, 1950, J APPL MECH-T ASME, V17, P299
[16]  
Kornhauser A.A., 1990, P PURD REFR PURD U W
[17]  
lEA Statistics, 2015, CO2 EM FUEL COMB
[18]   Study of ejector efficiencies in refrigeration cycles [J].
Liu, Fang ;
Groll, Eckhard A. .
APPLIED THERMAL ENGINEERING, 2013, 52 (02) :360-370
[19]   Ejector based organic flash combined power and refrigeration cycle (EBOFCP&RC) - A scheme for low grade waste heat recovery [J].
Mondal, Subha ;
De, Sudipta .
ENERGY, 2017, 134 :638-648
[20]   Power by waste heat recovery from low temperature industrial flue gas by Organic Flash Cycle (OFC) and transcritical-CO2 power cycle: A comparative study through combined thermodynamic and economic analysis [J].
Mondal, Subha ;
De, Sudipta .
ENERGY, 2017, 121 :832-840