Performance assessment of a low grade waste heat driven organic flash cycle (OFC) with ejector

被引:61
作者
Mondal, Subha [1 ]
Alam, Shahbaz [1 ]
De, Sudipta [2 ]
机构
[1] Aliah Univ, Dept Mech Engn, Kolkata 700156, India
[2] Jadavpur Univ, Dept Mech Engn, Kolkata 700032, India
关键词
Area utilization temperature indicator; Ejector; Entrainment ratio; OFC; Waste heat recovery; Pinch limitation; REFRIGERATION CYCLE; RANKINE-CYCLE; COMBINED POWER; ECONOMIC-ANALYSIS; WORKING FLUID; RECOVERY; SYSTEM; GAS; INTERMEDIATE; EFFICIENCIES;
D O I
10.1016/j.energy.2018.08.160
中图分类号
O414.1 [热力学];
学科分类号
摘要
Organic flash cycle (OFC) appears as one of the preferable options for waste heat recovery due to better matching of temperature profiles in the heat recovery unit (HRU). However, efficiency of an OFC reduces appreciably due to higher irreversibilities of the high pressure and the low pressure throttling devices. In the present study, to overcome this drawback low pressure throttle valve of the conventional OFC is replaced by an ejector. The saturated liquid stream exiting the vapour separator is accelerated in the nozzle of the ejector as primary flow and the stream coming out of the turbine is entrained in the ejector as secondary flow. Due to the presence of the ejector, the dry saturated vapour leaving the vapour separator of the OFC can be expanded in the turbine to a pressure which is lower than the specified condenser pressure. The turbine exit pressure is such that total working fluid mass exiting the diffuser of the ejector is at condenser pressure. OFC with ejector yields an increment of about 9.50% in both first law efficiency as well as power output compared to that of the conventional OFC. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:849 / 862
页数:14
相关论文
共 36 条
[1]  
[Anonymous], 2002, NIST STANDARD REFERE
[2]   Technical and economic analysis of organic flash regenerative cycles (OFRCs) for low temperature waste heat recovery [J].
Baccioli, A. ;
Antonelli, M. ;
Desideri, U. .
APPLIED ENERGY, 2017, 199 :69-87
[3]   Thermodynamic analyses on an ejector enhanced CO2 transcritical heat pump cycle with vapor-injection [J].
Bai, Tao ;
Yan, Gang ;
Yu, Jianlin .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 58 :22-34
[4]   Thermodynamics analysis of a modified dual-evaporator CO2 transcritical refrigeration cycle with two-stage ejector [J].
Bai, Tao ;
Yan, Gang ;
Yu, Jianlin .
ENERGY, 2015, 84 :325-335
[5]   A review of working fluid and expander selections for organic Rankine cycle [J].
Bao, Junjiang ;
Zhao, Li .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 24 :325-342
[6]   Application of an integrated lumped parameter-CFD approach to evaluate the ejector-driven anode recirculation in a PEM fuel cell system [J].
Besagni, Giorgio ;
Mereu, Riccardo ;
Inzoli, Fabio ;
Chiesa, Paolo .
APPLIED THERMAL ENGINEERING, 2017, 121 :628-651
[7]   A study of working fluids for heat driven ejector refrigeration using lumped parameter models [J].
Besagni, Giorgio ;
Mereu, Riccardo ;
Di Leo, Giuseppe ;
Inzoli, Fabio .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 58 :154-171
[8]   Performance analysis of a novel organic Rankine cycle with a vapor-liquid ejector [J].
Chen, Jianyong ;
Huang, Yisheng ;
Niu, Zhiting ;
Chen, Ying ;
Luo, Xianglong .
ENERGY CONVERSION AND MANAGEMENT, 2018, 157 :382-395
[9]   Investigation of ejectors in refrigeration system: Optimum performance evaluation and ejector area ratios perspectives [J].
Chen, Jianyong ;
Havtun, Hans ;
Palm, Bjorn .
APPLIED THERMAL ENGINEERING, 2014, 64 (1-2) :182-191
[10]   Performance of a solar ejector cooling-system in the southern region of Turkey [J].
Ersoy, H. Kursad ;
Yalcin, Sakir ;
Yapici, Rafet ;
Ozgoren, Muammer .
APPLIED ENERGY, 2007, 84 (09) :971-983