Comparing capsular bag performance of a hydrophilic and a hydrophobic intraocular lens: A randomised two-centre study

被引:6
作者
Koshy, John [1 ]
Hirnschall, Nino [1 ,2 ]
Vyas, Ashok Kumar V. [3 ]
Narendran, R. [3 ]
Crnej, Alja [1 ]
Gangwani, Vinod [1 ]
Nishi, Yutaro [1 ]
Maurino, Vincenzo [1 ]
Findl, Oliver [1 ,2 ]
机构
[1] Moorfields Eye Hosp NHS Fdn Trust, London, England
[2] Hanusch Hosp, VIROS, Heinrich Collin Str 30, A-1140 Vienna, Austria
[3] Scarborough Gen Hosp, Scarborough, England
关键词
Superflex; intraocular lens; optic size; OPTIC EDGE DESIGN; EPITHELIAL-CELL MIGRATION; HAPTIC DESIGN; OPACIFICATION; ANTERIOR; POLYMETHYLMETHACRYLATE; SILICONE; 1-PIECE; 3-PIECE; TRIAL;
D O I
10.1177/1120672117752133
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the capsular bag performance and posterior capsule opacification development of two intraocular lenses differing in material and design. Methods: This study included patients who were scheduled for cataract surgery and compared a hydrophilic intraocular lens (Superflex((R)) intraocular lens; Rayner Surgical, Worthing, UK) with a hydrophobic intraocular lens (AcrySof((R)) SA60AT; Alcon, Fort Worth, TX, USA). Follow-ups were performed 1 month and 2 years after cataract surgery, including a slit lamp examination and retroillumination images. Results: In total, 80 eyes of 80 patients were recruited. At the 1-month follow-up, 6 of 39 cases had a gap between the posterior lens capsule and intraocular lens (1 case in the hydrophilic intraocular lens group and 5 cases in the hydrophobic intraocular lens group; p = 0.348). Objective and subjective posterior capsule opacification scoring showed no statistically significant difference between both groups (p = 0.123). Conclusion: Both intraocular lens showed a good capsular bag performance and a relatively low posterior capsule opacification development within the first 2 years after surgery.
引用
收藏
页码:639 / 644
页数:6
相关论文
共 22 条
[1]   The effects of three-piece or single-piece acrylic intraocular lens implantation on posterior capsule opacification [J].
Bilge, AH ;
Aykan, Ü ;
Akin, T ;
Ünsal, U .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2004, 14 (05) :375-380
[2]   Long-term effect of optic edge design in an acrylic intraocular lens on posterior capsule opacification [J].
Buehl, W ;
Findl, O ;
Menapace, R ;
Sacu, S ;
Kriechbaum, K ;
Koeppl, C ;
Wirtitsch, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (05) :954-961
[3]   Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification [J].
Buehl, W ;
Findl, O ;
Menapace, R ;
Rainer, G ;
Sacu, S ;
Kiss, B ;
Petternel, V ;
Georgopoulos, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (07) :1105-1111
[4]   Reproducibility of standardized retroillumination photography for quantification of posterior capsule opacification [J].
Buehl, W ;
Findl, O ;
Menapace, R ;
Georgopoulos, M ;
Rainer, G ;
Wirtitsch, M ;
Siegl, H ;
Pinz, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :265-270
[5]   Comparison of 4 methods for quantifying posterior capsule opacification [J].
Findl, O ;
Buehl, W ;
Menapace, R ;
Georgopoulos, M ;
Rainer, G ;
Siegl, H ;
Kaider, A ;
Pinz, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (01) :106-111
[6]  
Findl O, 2004, J CATARACT REFR SURG, V30, P1875
[7]   Capsular bag performance of a hydrophobic acrylic 1-piece intraocular lens [J].
Findl, Oliver ;
Hirnschall, Nino ;
Nishi, Yutaro ;
Maurino, Vincenzo ;
Crnej, Alia .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (01) :90-97
[8]   Interventions for preventing posterior capsule opacification [J].
Findl, Oliver ;
Buehl, Wolf ;
Bauer, Peter ;
Sycha, Thomas .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2010, (02)
[9]   Posterior capsule opacification and capsular bag performance of a microincision intraocular lens [J].
Gangwani, Vinod ;
Hirnschall, Nino ;
Koshy, John ;
Crnej, Alja ;
Nishi, Yutaro ;
Maurino, Vincenzo ;
Findl, Oliver .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (11) :1988-1992
[10]   Posterior capsular opacification with hydrogel, polymethylmethacrylate, and silicone intraocular lenses: Two-year results of a randomized prospective trial [J].
Hollick, EJ ;
Spalton, DJ ;
Ursell, PG ;
Meacock, WR ;
Barman, SA ;
Boyce, JF .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (05) :577-584