Prior image-guided cone-beam computed tomography augmentation from under-sampled projections using a convolutional neural network

被引:7
作者
Jiang, Zhuoran [1 ]
Zhang, Zeyu [3 ]
Chang, Yushi [3 ]
Ge, Yun [2 ]
Yin, Fang-Fang [1 ,3 ,4 ]
Ren, Lei [5 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC USA
[2] Nanjing Univ, Sch Elect Sci & Engn, Nanjing, Peoples R China
[3] Duke Univ, Med Phys Grad Program, Durham, NC USA
[4] Duke Kunshan Univ, Med Phys Grad Program, Kunshan, Peoples R China
[5] Univ Maryland, Dept Radiat Oncol, Baltimore, MD 21201 USA
基金
美国国家卫生研究院;
关键词
Under-sampled CBCT augmentation; deep learning; prior-image guidance; merging-encoder; CT RECONSTRUCTION; PRIOR INFORMATION; 4D-CBCT;
D O I
10.21037/qims-21-114
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Acquiring sparse-view cone-beam computed tomography (CBCT) is an effective way to reduce the imaging dose. However, images reconstructed by the conventional filtered back-projection method suffer from severe streak artifacts due to the projection under-sampling. Existing deep learning models have demonstrated feasibilities in restoring volumetric structures from the highly under-sampled images. However, because of the inter-patient variabilities, they failed to restore the patient-specific details with the common restoring pattern learned from the group data. Although the patient-specific models have been developed by training models using the intra-patient data and have shown effectiveness in restoring the patient-specific details, the models have to be retrained to be exclusive for each patient. It is highly desirable to develop a generalized model that can utilize the patient-specific information for the under-sampled image augmentation. Methods: In this study, we proposed a merging-encoder convolutional neural network (MeCNN) to realize the prior image-guided under-sampled CBCT augmentation. Instead of learning the patient-specific structures, the proposed model learns a generalized pattern of utilizing the patient-specific information in the prior images to facilitate the under-sampled image enhancement. Specifically, the MeCNN consists of a merging-encoder and a decoder. The merging-encoder extracts image features from both the prior CT images and the under-sampled CBCT images, and merges the features at multi-scale levels via deep convolutions. The merged features are then connected to the decoders via shortcuts to yield high-quality CBCT images. The proposed model was tested on both the simulated CBCTs and the clinical CBCTs. The predicted CBCT images were evaluated qualitatively and quantitatively in terms of image quality and tumor localization accuracy. Mann-Whitney U test was conducted for the statistical analysis. P<0.05 was considered statistically significant. Results: The proposed model yields CT-like high-quality CBCT images from only 36 half-fan projections. Compared to other methods, CBCT images augmented by the proposed model have significantly lower intensity errors, significantly higher peak signal-to-noise ratio, and significantly higher structural similarity with respect to the ground truth images. Besides, the proposed method significantly reduced the 3D distance of the CBCT-based tumor localization errors. In addition, the CBCT augmentation is nearly real-time. Conclusions: With the prior-image guidance, the proposed method is effective in reconstructing high-quality CBCT images from the highly under-sampled projections, considerably reducing the imaging dose and improving the clinical utility of the CBCT.
引用
收藏
页码:4767 / 4780
页数:14
相关论文
共 27 条
[1]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[2]   Edge guided image reconstruction in linear scan CT by weighted alternating direction TV minimization [J].
Cai, Ailong ;
Wang, Linyuan ;
Zhang, Hanming ;
Yan, Bin ;
Li, Lei ;
Xi, Xiaoqi ;
Li, Jianxin .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2014, 22 (03) :335-349
[3]   Four-dimensional deformable image registration using trajectory modeling [J].
Castillo, Edward ;
Castillo, Richard ;
Martinez, Josue ;
Shenoy, Maithili ;
Guerrero, Thomas .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (01) :305-327
[4]   Low dose CBCT reconstruction via prior contour based total variation (PCTV) regularization: a feasibility study [J].
Chen, Yingxuan ;
Yin, Fang-Fang ;
Zhang, Yawei ;
Zhang, You ;
Ren, Lei .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (08)
[5]   Deformable Convolutional Networks [J].
Dai, Jifeng ;
Qi, Haozhi ;
Xiong, Yuwen ;
Li, Yi ;
Zhang, Guodong ;
Hu, Han ;
Wei, Yichen .
2017 IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION (ICCV), 2017, :764-773
[6]   Robust Physical-World Attacks on Deep Learning Visual Classification [J].
Eykholt, Kevin ;
Evtimov, Ivan ;
Fernandes, Earlence ;
Li, Bo ;
Rahmati, Amir ;
Xiao, Chaowei ;
Prakash, Atul ;
Kohno, Tadayoshi ;
Song, Dawn .
2018 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2018, :1625-1634
[7]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[8]  
Han YS., 2016, ARXIV PREPRINT ARXIV
[9]   Estimating 4D-CBCT from prior information and extremely limited angle projections using structural PCA and weighted free-form deformation for lung radiotherapy [J].
Harris, Wendy ;
Zhang, You ;
Yin, Fang-Fang ;
Ren, Lei .
MEDICAL PHYSICS, 2017, 44 (03) :1089-1104
[10]   A longitudinal four-dimensional computed tomography and cone beam computed tomography dataset for image-guided radiation therapy research in lung cancer [J].
Hugo, Geoffrey D. ;
Balik, Salim ;
Keall, Paul J. ;
Lu, Jun ;
Williamson, Jeffrey F. .
MEDICAL PHYSICS, 2017, 44 (02) :762-771