A Randomized, Double-Blind, Controlled Study of Ultrasound-Guided Corticosteroid Injection Into the Joint of Patients With Inflammatory Arthritis

被引:166
|
作者
Cunnington, Joanna [2 ,3 ]
Marshall, Nicola [3 ]
Hide, Geoff [3 ]
Bracewell, Claire [3 ]
Isaacs, John [2 ,3 ]
Platt, Philip [3 ]
Kane, David [1 ,2 ]
机构
[1] Adelaide & Meath Hosp, Dept Rheumatol, Dublin 24, Ireland
[2] Newcastle Univ, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
[3] Freeman Rd Hosp, Newcastle Upon Tyne NE7 7DN, Tyne & Wear, England
来源
ARTHRITIS AND RHEUMATISM | 2010年 / 62卷 / 07期
关键词
RHEUMATOID-ARTHRITIS; CLINICAL EXAMINATION; NEEDLE PLACEMENT; ULTRASONOGRAPHY; ACCURACY; KNEE; RHEUMATOLOGISTS; ASPIRATION; SHOULDER; EUROQOL;
D O I
10.1002/art.27448
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. Most corticosteroid injections into the joint are guided by the clinical examination (CE), but up to 70% are inaccurately placed, which may contribute to an inadequate response. The aim of this study was to investigate whether ultrasound (US) guidance improves the accuracy and clinical outcome of joint injections as compared with CE guidance in patients with inflammatory arthritis. Methods. A total of 184 patients with inflammatory arthritis and an inflamed joint (shoulder, elbow, wrist, knee, or ankle) were randomized to receive either US-guided or CE-guided corticosteroid injections. Visual analog scales (VAS) for assessment of function, pain, and stiffness of the target joint, a modified Health Assessment Questionnaire, and the EuroQol 5-domain questionnaire were obtained at baseline and at 2 weeks and 6 weeks postinjection. The erythrocyte sedimentation rate and C-reactive protein level were measured at baseline and 2 weeks. Contrast injected with the steroid was used to assess the accuracy of the joint injection. Results. One-third of CE-guided injections were inaccurate. US-guided injections performed by a trainee rheumatologist were more accurate than the CE-guided injections performed by more senior rheumatologists (83% versus 66%; P = 0.010). There was no significant difference in clinical outcome between the group receiving US-guided injections and the group receiving CE-guided injections. Accurate injections led to greater improvement in joint function, as determined by VAS scores, at 6 weeks, as compared with inaccurate injections (30.6 mm versus 21.2 mm; P = 0.030). Clinicians who used US guidance reliably assessed the accuracy of joint injection (P < 0.001), whereas those who used CE guidance did not (P = 0.29). Conclusion. US guidance significantly improves the accuracy of joint injection, allowing a trainee to rapidly achieve higher accuracy than more experienced rheumatologists. US guidance did not improve the short-term outcome of joint injection.
引用
收藏
页码:1862 / 1869
页数:8
相关论文
共 50 条
  • [31] Ultrasound-Guided BoNT-A (Botulinum Toxin A) Injection Into the Subscapularis for Hemiplegic Shoulder Pain A Randomized, Double-Blind, Placebo-Controlled Trial
    Tan, Botao
    Jia, Lang
    STROKE, 2021, 52 (12) : 3759 - 3767
  • [32] Local Anesthesia Prior to Ultrasound-Guided Hip Joint Injections: A Double-Blind Randomized Controlled Trial of Bacteriostatic Saline versus Buffered Lidocaine
    Kruse, Ryan C.
    Kindle, Brett J.
    Wisniewski, Steve
    Presley, James
    Smith, Jay
    Sellon, Jacob L.
    PM&R, 2021, 13 (08) : 811 - 818
  • [33] Ultrasound-Guided Single-Penetration Dual-Injection Block for Leg and Foot Surgery A Prospective, Randomized, Double-blind Study
    Borglum, Jens
    Johansen, Karina
    Christensen, Margrethe D.
    Lenz, Katja
    Bendtsen, Thomas F.
    Tanggaard, Katrine
    Christensen, Anders F.
    Moriggl, Bernhard
    Jensen, Kenneth
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2014, 39 (01) : 18 - 25
  • [35] Desmopressin Acetate in Percutaneous Ultrasound-Guided Native Kidney Biopsy in Patients with Reduced Kidney Function: A Double-Blind Randomized Controlled Trial
    Sattari, Shahab Aldin
    Shahoori, Azita
    Shahbazian, Heshmatollah
    Sabetnia, Leila
    Aref, Asieh
    Sattari, Ali Reza
    Ghorbani, Ali
    IRANIAN JOURNAL OF KIDNEY DISEASES, 2022, 16 (04) : 238 - 245
  • [36] Comparison of tacrolimus and mizoribine in a randomized, double-blind controlled study in patients with rheumatoid arthritis
    Kawai, Shinichi
    Hashimoto, Hiroshi
    Kondo, Hirobumi
    Murayama, Takashi
    Kiuchi, Takahiro
    Abe, Toru
    JOURNAL OF RHEUMATOLOGY, 2006, 33 (11) : 2153 - 2161
  • [37] Periprostatic administration of local anesthesia during transrectal ultrasound-guided biopsy of the prostate: A randomized, double-blind, placebo-controlled study
    Berger, AP
    Frauscher, F
    Halpern, EJ
    Spranger, R
    Steiner, H
    Bartsch, G
    Horninger, W
    UROLOGY, 2003, 61 (03) : 585 - 588
  • [38] Ultrasound-guided transversus abdominis plane block for post-cesarean analgesia: a double-blind randomized controlled trial
    Shields Pimentel, R.
    Galbo, P.
    Rachel Ponce, A.
    Rose Taladro, M.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2021, 128 : 144 - 144
  • [39] A Randomized Double-Blind Controlled Trial to Assess the Efficacy of Ultrasound-Guided Erector Spinae Plane Block in Cardiac Surgery
    Athar, Manazir
    Parveen, Sania
    Yadav, Mayank
    Siddiqui, Obaid Ahmed
    Nasreen, Farah
    Ali, Shahna
    Haseen, Mohd Azam
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2021, 35 (12) : 3574 - 3580
  • [40] Corticosteroid injection in hip osteoarthritis: A randomized double-blind placebo-controlled trial.
    Maksymowych, Walter P.
    Conner-Spady, Barbara
    Grace, Michael G.
    Jhangri, Gian S.
    Lambert, Robert G. W.
    ARTHRITIS AND RHEUMATISM, 2006, 54 (09): : S674 - S675