An Impedimetric Biosensor Based on Ionic Liquid-Modified Graphite Electrodes Developed for microRNA-34a Detection

被引:19
作者
Kesici, Ece [1 ,2 ]
Eksin, Ece [1 ,2 ]
Erdem, Arzum [1 ,2 ]
机构
[1] Ege Univ, Analyt Chem Dept, Fac Pharm, TR-35100 Bornova, Turkey
[2] Ege Univ, Inst Nat & Appl Sci, Biotechnol Dept, TR-35100 Bornova, Turkey
关键词
ionic liquid; pencil graphite electrode; microRNA; electrochemical impedance spectroscopy; fetal bovine serum; nucleic acid hybridization; FREE ELECTROCHEMICAL BIOSENSOR; GRAPHENE OXIDE; IMPEDANCE SPECTROSCOPY; CHITOSAN; LABEL; GOLD; BIOMARKERS; SURFACE;
D O I
10.3390/s18092868
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present work, an impedimetric nucleic acid biosensor has been designed for the purpose of detection of microRNA (miRNA). Ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate (IL))-modified chemically activated pencil graphite electrodes (PGEs) were used for the sensitive and selective detection of miRNA-34a. After covalent activation of the PGE surface using covalent agents (CAs), the ionic liquid (IL) was immobilized onto the surface of the chemically activated PGE by passive adsorption. The electrochemical and microscopic characterization of the IL/CA/PGEs was performed by electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and scanning electron microscopy (SEM). DNA probe concentration, miRNA target concentration, and also the hybridization time and wet adsorption time were optimized by using the EIS technique. Then, the hybridization occurred between specific DNA probes and miRNA-34a was immobilized onto the surface of the IL/CA/PGEs. The impedimetric detection of miRNA-DNA hybrid was performed by EIS. The detection limit (DL) was calculated in a linear concentration range of 2-10 mu g/mL miRNA-34a target, and it was found to be 0.772 mu g/mL (109 nM) in phosphate buffer solution (PBS) and 0.826 mu g/mL (117 nM) in diluted fetal bovine serum (FBS). The selectivity of impedimetric biosensor for miRNA-34a was also tested against to other non-complementary miRNA sequences both in buffer media, or diluted FBS.
引用
收藏
页数:15
相关论文
共 44 条
[1]   An integrated dual functional recognition/amplification bio-label for the one-step impedimetric detection of Micro-RNA-21 [J].
Azzouzi, Sawsen ;
Mak, Wing Cheung ;
Kor, Kamalodin ;
Turner, Anthony P. F. ;
Ben Ali, Mounir ;
Beni, Valerio .
BIOSENSORS & BIOELECTRONICS, 2017, 92 :154-161
[2]   Dicer is essential for mouse development [J].
Bernstein, E ;
Kim, SY ;
Carmell, MA ;
Murchison, EP ;
Alcorn, H ;
Li, MZ ;
Mills, AA ;
Elledge, SJ ;
Anderson, KV ;
Hannon, GJ .
NATURE GENETICS, 2003, 35 (03) :215-217
[3]   Electrochemical detection of miRNA-222 by use of a magnetic bead-based bioassay [J].
Bettazzi, Francesca ;
Hamid-Asl, Ezat ;
Esposito, Carla Lucia ;
Quintavalle, Cristina ;
Formisano, Nello ;
Laschi, Serena ;
Catuogno, Silvia ;
Iaboni, Margherita ;
Marrazza, Giovanna ;
Mascini, Marco ;
Cerchia, Laura ;
De Franciscis, Vittorio ;
Condorelli, Gerolama ;
Palchetti, Ilaria .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (2-3) :1025-1034
[4]   A label-free electrochemical biosensor for microRNA detection based on catalytic hairpin assembly and in situ formation of molybdophosphate [J].
Cai, Wei ;
Xie, Shunbi ;
Tang, Ying ;
Chai, Yaqin ;
Yuan, Ruo ;
Zhang, Jin .
TALANTA, 2017, 163 :65-71
[5]   Identification of miRNA changes in Alzheimer's disease brain and CSF yields putative biomarkers and insights into disease pathways [J].
Cogswell, John P. ;
Ward, James ;
Taylor, Ian A. ;
Waters, Michelle ;
Shi, Yunling ;
Cannon, Brian ;
Kelnar, Kevin ;
Kemppainen, Jon ;
Brown, David ;
Chen, Caifu ;
Prinjha, Rab K. ;
Richardson, Jill C. ;
Saunders, Ann M. ;
Roses, Allen D. ;
Richards, Cynthia A. .
JOURNAL OF ALZHEIMERS DISEASE, 2008, 14 (01) :27-41
[6]   Electrocatalytic miRNA Detection Using Cobalt Porphyrin-Modified Reduced Graphene Oxide [J].
De Souza, Camille ;
Zrig, Samia ;
Wang, Dengjun ;
Minh-Chau Pham ;
Piro, Benoit .
SENSORS, 2014, 14 (06) :9984-9994
[7]  
Eksin E., 2013, ELECTROANAL, V25, P1, DOI DOI 10.1002/ELAN.201300188
[8]   Nanomaterial-based electrochemical DNA sensing strategies [J].
Erdem, Arzum .
TALANTA, 2007, 74 (03) :318-325
[9]   Graphene Oxide Modified Chemically Activated Graphite Electrodes for Detection of microRNA [J].
Erdem, Arzum ;
Eksin, Ece ;
Isin, Deniz ;
Polat, Derya .
ELECTROANALYSIS, 2017, 29 (05) :1350-1358
[10]   Indicator-free electrochemical biosensor for microRNA detection based on carbon nanofibers modified screen printed electrodes [J].
Erdem, Arzum ;
Eksin, Ece ;
Congur, Gulsah .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 755 :167-173