Marker-based ballistocardiographic artifact correction improves spike identification in EEG-fMRI of focal epilepsy patients

被引:6
作者
Koerbl, Katharina [1 ,3 ]
Jacobs, Julia [1 ,2 ]
Herbst, Michael [3 ,4 ]
Zaitsev, Maxim [3 ]
Schulze-Bonhage, Andreas [2 ]
Hennig, Juergen [3 ]
LeVan, Pierre [3 ]
机构
[1] Univ Freiburg, Dept Neuropediat & Muscular Dis, Med Ctr, Fac Med, Freiburg, Germany
[2] Univ Freiburg, Med Ctr, Epilepsy Ctr, Fac Med, Freiburg, Germany
[3] Univ Freiburg, Med Ctr, Dept Radiol, Med Phys,Fac Med, Freiburg, Germany
[4] Univ Hawaii, John A Burns Sch Med, Dept Med, Honolulu, HI 96822 USA
基金
欧洲研究理事会;
关键词
Ballistocardiographic artifact correction; Epileptic spike/IED; Refractory epilepsy; EEG-fMRI; Fast fMRI; Optical tracking; MPT marker; FUNCTIONAL MRI; PULSE ARTIFACT; REMOVAL; MOTION; RECORDINGS; ELECTROENCEPHALOGRAPHY; LOCALIZATION; SENSITIVITY; REDUCTION; QUALITY;
D O I
10.1016/j.clinph.2016.05.361
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objectives: Ballistocardiographic (BCG) artifacts resemble interictal epileptic discharges (IEDs) and can lead to incorrect IED identification in EEG-fMRI. This study investigates IEDs marked in EEGs corrected using information from a moire phase tracking (MPT) marker. Methods: EEG-fMRI from 18 patients was processed with conventional methods for BCG removal, while 9 patients used a MPT marker. IEDs were marked first without ECG information. In a second review, suspicious IEDs synchronous with the BCG were discarded. After each review, an event-related fMRI analysis was performed on the marked IEDs. Results: No difference was found in the proportion of suspicious IEDs in the 2 patient groups. However, the distribution of IED timings was significantly related to the cardiac cycle in 11 of 18 patients recorded without MPT marker, but only 2 of 9 patients with marker. In patients recorded without marker, failing to discard suspicious IEDs led to more inaccurate fMRI maps and more distant activations. Conclusions: BCG artifact correction based on MPT recordings allowed a more straightforward identification of IEDs that did not require ECG information in the large majority of patients. Significance: Marker-based ballistocardiographic artifact correction greatly facilitates the study of the generators of interictal discharges with EEG-fMRI. (C) 2016 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:2802 / 2811
页数:10
相关论文
共 58 条
[41]   Removal of time-varying gradient artifacts from EEG data acquired during continuous fMRI [J].
Negishi, M ;
Abildgaard, M ;
Nixon, T ;
Constable, RT .
CLINICAL NEUROPHYSIOLOGY, 2004, 115 (09) :2181-2192
[42]   Removal of FMRI environment artifacts from EEG data using optimal basis sets [J].
Niazy, RK ;
Beckmann, CF ;
Iannetti, GD ;
Brady, JM ;
Smith, SM .
NEUROIMAGE, 2005, 28 (03) :720-737
[43]  
Niedermeyer E., 2005, Electroencephalography: basic principles, clinical applications
[44]   Classification of EEG abnormalities in partial epilepsy with simultaneous EEG-fMRI recordings [J].
Pedreira, C. ;
Vaudano, A. E. ;
Thornton, R. C. ;
Chaudhary, U. J. ;
Vulliemoz, S. ;
Laufs, H. ;
Rodionov, R. ;
Carmichael, D. W. ;
Lhatoo, S. D. ;
Guye, M. ;
Quiroga, R. Quian ;
Lemieux, L. .
NEUROIMAGE, 2014, 99 :461-476
[45]   Enhancement of temporal resolution and BOLD sensitivity in real-time fMRI using multi-slab echo-volumar imaging [J].
Posse, Stefan ;
Ackley, Elena ;
Mutihac, Radu ;
Rick, Jochen ;
Shane, Matthew ;
Murray-Krezan, Cristina ;
Zaitsev, Maxim ;
Speck, Oliver .
NEUROIMAGE, 2012, 61 (01) :115-130
[46]   Non-invasive epileptic focus localization using EEG-triggered functional MRI and electromagnetic tomography [J].
Seeck, M ;
Lazeyras, F ;
Michel, CM ;
Blanke, O ;
Gericke, CA ;
Ives, J ;
Delavelle, J ;
Golay, X ;
Haenggeli, CA ;
de Tribolet, N ;
Landis, T .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 106 (06) :508-512
[47]   Spatial filters and automated spike detection based on brain topographies improve sensitivity of EEG-fMRT studies in focal epilepsy [J].
Siniatchkin, Michael ;
Moeller, Friederike ;
Jacobs, Julia ;
Stephani, Ulrich ;
Boor, Rainer ;
Wolff, Stephan ;
Jansen, Olav ;
Siebner, Hartwig ;
Scherg, Michael .
NEUROIMAGE, 2007, 37 (03) :834-843
[48]   Advances in functional and structural MR image analysis and implementation as FSL [J].
Smith, SM ;
Jenkinson, M ;
Woolrich, MW ;
Beckmann, CF ;
Behrens, TEJ ;
Johansen-Berg, H ;
Bannister, PR ;
De Luca, M ;
Drobnjak, I ;
Flitney, DE ;
Niazy, RK ;
Saunders, J ;
Vickers, J ;
Zhang, YY ;
De Stefano, N ;
Brady, JM ;
Matthews, PM .
NEUROIMAGE, 2004, 23 :S208-S219
[49]   ICA-based procedures for removing ballistocardiogram artifacts from EEG data acquired in the MRI scanner [J].
Srivastava, G ;
Crottaz-Herbette, S ;
Lau, KM ;
Glover, GH ;
Menon, V .
NEUROIMAGE, 2005, 24 (01) :50-60
[50]   Removal of BCG artifacts from EEG recordings inside the MR scanner: A comparison of methodological and validation-related aspects [J].
Vanderperren, Katrien ;
De Vos, Maarten ;
Ramautar, Jennifer R. ;
Novitskiy, Nikolay ;
Mennes, Maarten ;
Assecondi, Sara ;
Vanrumste, Bart ;
Stiers, Peter ;
Van den Bergh, Bea R. H. ;
Wagemans, Johan ;
Lagae, Lieven ;
Sunaert, Stefan ;
Van Huffel, Sabine .
NEUROIMAGE, 2010, 50 (03) :920-934