Marker-based ballistocardiographic artifact correction improves spike identification in EEG-fMRI of focal epilepsy patients

被引:6
作者
Koerbl, Katharina [1 ,3 ]
Jacobs, Julia [1 ,2 ]
Herbst, Michael [3 ,4 ]
Zaitsev, Maxim [3 ]
Schulze-Bonhage, Andreas [2 ]
Hennig, Juergen [3 ]
LeVan, Pierre [3 ]
机构
[1] Univ Freiburg, Dept Neuropediat & Muscular Dis, Med Ctr, Fac Med, Freiburg, Germany
[2] Univ Freiburg, Med Ctr, Epilepsy Ctr, Fac Med, Freiburg, Germany
[3] Univ Freiburg, Med Ctr, Dept Radiol, Med Phys,Fac Med, Freiburg, Germany
[4] Univ Hawaii, John A Burns Sch Med, Dept Med, Honolulu, HI 96822 USA
基金
欧洲研究理事会;
关键词
Ballistocardiographic artifact correction; Epileptic spike/IED; Refractory epilepsy; EEG-fMRI; Fast fMRI; Optical tracking; MPT marker; FUNCTIONAL MRI; PULSE ARTIFACT; REMOVAL; MOTION; RECORDINGS; ELECTROENCEPHALOGRAPHY; LOCALIZATION; SENSITIVITY; REDUCTION; QUALITY;
D O I
10.1016/j.clinph.2016.05.361
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objectives: Ballistocardiographic (BCG) artifacts resemble interictal epileptic discharges (IEDs) and can lead to incorrect IED identification in EEG-fMRI. This study investigates IEDs marked in EEGs corrected using information from a moire phase tracking (MPT) marker. Methods: EEG-fMRI from 18 patients was processed with conventional methods for BCG removal, while 9 patients used a MPT marker. IEDs were marked first without ECG information. In a second review, suspicious IEDs synchronous with the BCG were discarded. After each review, an event-related fMRI analysis was performed on the marked IEDs. Results: No difference was found in the proportion of suspicious IEDs in the 2 patient groups. However, the distribution of IED timings was significantly related to the cardiac cycle in 11 of 18 patients recorded without MPT marker, but only 2 of 9 patients with marker. In patients recorded without marker, failing to discard suspicious IEDs led to more inaccurate fMRI maps and more distant activations. Conclusions: BCG artifact correction based on MPT recordings allowed a more straightforward identification of IEDs that did not require ECG information in the large majority of patients. Significance: Marker-based ballistocardiographic artifact correction greatly facilitates the study of the generators of interictal discharges with EEG-fMRI. (C) 2016 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:2802 / 2811
页数:10
相关论文
共 58 条
[11]   Avoiding the ballistocardiogram (BCG) artifact of EEG data acquired simultaneously with fMRI by pulse-triggered presentation of stimuli [J].
Ertl, Matthias ;
Kirsch, Valerie ;
Leicht, Gregor ;
Karch, Susanne ;
Olbrich, Sebastian ;
Reiser, Maximilian ;
Hegerl, Ulrich ;
Pogarell, Oliver ;
Mulert, Chistoph .
JOURNAL OF NEUROSCIENCE METHODS, 2010, 186 (02) :231-241
[12]  
Felblinger J, 1999, MAGN RESON MED, V41, P715, DOI 10.1002/(SICI)1522-2594(199904)41:4<715::AID-MRM9>3.0.CO
[13]  
2-7
[14]   How wrong can we be? The effect of inaccurate mark-up of EEG/fMRI studies in epilepsy [J].
Flanagan, Danny ;
Abbott, David F. ;
Jackson, Graeme D. .
CLINICAL NEUROPHYSIOLOGY, 2009, 120 (09) :1637-1647
[15]   Real-time MR artifacts filtering during continuous EEG/fMRI acquisition [J].
Garreffa, G ;
Carnì, M ;
Gualniera, G ;
Ricci, GB ;
Bozzao, L ;
De Carli, D ;
Morasso, P ;
Pantano, P ;
Colonnese, C ;
Roma, V ;
Maraviglia, B .
MAGNETIC RESONANCE IMAGING, 2003, 21 (10) :1175-1189
[16]  
Glover GH, 2000, MAGNET RESON MED, V44, P162, DOI 10.1002/1522-2594(200007)44:1<162::AID-MRM23>3.0.CO
[17]  
2-E
[18]   Epileptic networks studied with EEG-fMRI [J].
Gotman, Jean .
EPILEPSIA, 2008, 49 :42-51
[19]   Combining EEG and fMRI in the study of epileptic discharges [J].
Gotman, Jean ;
Pittau, Francesca .
EPILEPSIA, 2011, 52 :38-42
[20]   A comparative study of different artefact removal algorithms for EEG signals acquired during functional MRI [J].
Grouiller, Frederic ;
Vercueil, Laurent ;
Krainik, Alexandre ;
Segebarth, Christoph ;
Kahane, Philippe ;
David, Olivier .
NEUROIMAGE, 2007, 38 (01) :124-137