ULTRASOUND QUANTIFICATION OF ACETABULAR ROUNDING IN HIP DYSPLASIA: RELIABILITY AND CORRELATION TO TREATMENT DECISIONS IN A RETROSPECTIVE STUDY

被引:8
作者
Cheng, Edwin [1 ]
Mabee, Myles [2 ]
Swami, Vimarsha G. [1 ]
Pi, Yeli [1 ]
Thompson, Richard [2 ]
Dulai, Sukhdeep [3 ]
Jaremko, Jacob L. [1 ]
机构
[1] Univ Alberta, Dept Radiol & Diagnost Imaging, Edmonton, AB T6G 2B7, Canada
[2] Univ Alberta, Res Translat Facil 1082, Dept Biomed Engn, Edmonton, AB T6G 2B7, Canada
[3] Univ Alberta, Dept Surg, Div Orthoped Surg, Edmonton, AB T6G 2B7, Canada
关键词
Developmental dysplasia of the hip; alpha angle; Acetabular rounding; Reliability; Ultrasound; DEVELOPMENTAL DYSPLASIA; RISK-FACTORS; ULTRASONOGRAPHY; DIAGNOSIS; NEWBORN;
D O I
10.1016/j.ultrasmedbio.2014.08.007
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Currently, acetabular rounding is only subjectively assessed on ultrasound for developmental dysplasia of the hip. We tested whether acetabular rounding can be quantified reliably and can distinguish between hips requiring and not requiring treatment. Consecutive infants (n = 90) suspected of having dysplasia of the hip, seen at a pediatric orthopedic clinic, were separated into four diagnostic categories (normal, borderline but resolved, treated by brace, treated surgically). Acetabular rounding was assessed by semi-quantitative grade (0 = nil, 1 = mild, 2 = moderate, 3 = severe) by three observers and by direct measurement of acetabular radius of curvature (AROC) by two observers. Inter-observer reliability of rounding grade was poor (k = 0.30-0.37). AROC had an inter-observer intra-class correlation coefficient of 0.84 and coefficient of variation of 29%-34%. Mean AROC was significantly higher for hips requiring treatment than for those not requiring treatment (3.3 mm vs. 1.6 mm, p = 0.007). AROC reliably quantifies an observation currently being made subjectively by radiologists and surgeons, and may be useful as a supplementary ultrasound index of dysplasia of the hip in future prospective studies. (C) 2015 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:56 / 63
页数:8
相关论文
共 15 条
[11]   Ultrasound measurements in the management of unstable hips treated with the Pavlik harness - Reliability and correlation with outcome [J].
Jones, David P. Gwynne ;
Vane, Andrew G. S. ;
Coulter, Gareth ;
Herbison, Peter ;
Dunbar, John D. .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2006, 26 (06) :818-822
[12]   Measuring acetabular dysplasia in plain radiographs [J].
Lee, Young-Kyun ;
Chung, Chin Youb ;
Koo, Kyung-Hoi ;
Lee, Kyoung Min ;
Kwon, Dae Gyu ;
Park, Moon Seok .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (09) :1219-1226
[13]   Ultrasound screening for hips at risk in developmental dysplasia - Is it worth it? [J].
Paton, RW ;
Srinivasan, MS ;
Shah, B ;
Hollis, S .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (02) :255-258
[14]   Screening the newborn for developmental dysplasia of the hip - Now what do we do? [J].
Schwend, Richard M. ;
Schoenecker, Perry ;
Richards, B. Stephens ;
Flynn, John M. ;
Vitale, Michael .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2007, 27 (06) :607-610
[15]  
Yavuz OY, 2014, J PEDIATR ORTHOPED, V34, P591, DOI 10.1097/BPO.0000000000000159