Ultra-Wideband Pulse Generator for Heart-Rate Monitor

被引:1
作者
Liu, Xiaoyan [1 ]
Fang, Zheng [1 ]
Zhou, Jianguang [1 ]
机构
[1] Zhejiang Univ, Dept Control Sci & Engn, Hangzhou 310003, Zhejiang, Peoples R China
来源
PRACTICAL APPLICATIONS OF INTELLIGENT SYSTEMS, ISKE 2013 | 2014年 / 279卷
关键词
Heart-rate monitor; UWB pulse generator; RF-BJT; Simulation; Circuit board;
D O I
10.1007/978-3-642-54927-4_12
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Ultra-wideband (UWB) heart-rate monitor designed in this text mainly consists of controller, pulse generator, pulse receiver, and displayer. Controller controls the pulse generating and receiving and heart-rate display. Based on the characteristics of avalanche of RF-BJT, we designed an UWB pulse generator in this paper. By simulating and debugging, we successfully obtained the bipolar UWB pulse, with the peak-to-valley voltage 6.7 V and peak-to-valley width 600 ps. The pulse generating circuit is suitable for the UWB heart-rate monitor, with its simple structure, low cost, and good performance.
引用
收藏
页码:123 / 132
页数:10
相关论文
共 25 条
  • [21] Pulse Oximetry Color Coded Heart Rate Monitoring System Using ZigBee
    Harun, F. K. Che
    Zulkarnain, N.
    Ab Aziz, M. F.
    Mahmood, N. H.
    Kamarudin, M. F.
    Linoby, A.
    5TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2011 (BIOMED 2011), 2011, 35 : 348 - +
  • [22] Arterial viscoelasticity: role in the dependency of pulse wave velocity on heart rate in conduit arteries
    Xiao, Hanguang
    Tan, Isabella
    Butlin, Mark
    Li, Decai
    Avolio, Alberto P.
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2017, 312 (06): : H1185 - H1194
  • [23] Estimating energy expenditure of head-hauling water and grain grinding from heart rate monitor measurements in northern Mozambique
    Russel, Kory C.
    Buman, Matthew P.
    Davis, Jennifer
    Haskell, William L.
    PUBLIC HEALTH NUTRITION, 2020, 23 (16) : 2886 - 2897
  • [24] Effectiveness of an aerobic walking program using heart rate monitor and pedometer on the parameters of diabetes control in Asian Indians with type 2 diabetes
    Shenoy, Shweta
    Guglani, Ruchika
    Sandhu, Jaspal Singh
    PRIMARY CARE DIABETES, 2010, 4 (01) : 41 - 45
  • [25] Accuracy of the Polar S810i™ heart rate monitor and the Sensewear Pro Armband™ to estimate energy expenditure of indoor rowing exercise in overweight and obese individuals
    Erdogan, Ali
    Cetin, Cem
    Karatosun, Hilmi
    Baydar, Metin Lutfi
    JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2010, 9 (03) : 508 - 516