Rationale behind the optimum efficiency of columns packed with new 1.9 μm fully porous particles of narrow particle size distribution

被引:50
作者
Catani, Martina [1 ]
Ismail, Omar H. [2 ]
Cavazzini, Alberto [1 ]
Ciogli, Alessia [2 ]
Villani, Claudio [2 ]
Pasti, Luisa [1 ]
Bergantin, Caterina [1 ]
Cabooter, Deirdre [3 ]
Desmet, Gert [4 ]
Gasparrini, Francesco [2 ]
Bell, David S. [5 ]
机构
[1] Univ Ferrara, Dept Chem & Pharmaceut Sci, Via L Borsari 46, I-44121 Ferrara, Italy
[2] Univ Roma La Sapienza, Dept Drug Chem & Technol, Ple A Moro 5, I-00185 Rome, Italy
[3] Katholieke Univ Leuven, Dept Pharmaceut Sci, Pharmaceut Anal, Herestr 49, B-3000 Leuven, Belgium
[4] Vrije Univ Brussel, Dept Chem Engn, B-1050 Brussels, Belgium
[5] Millipore Sigma, Appl Res & Dev, 595 North Harrison Rd, Bellefonte, PA 16823 USA
关键词
Column efficiency; Sub-2 mu m fully porous particles of narrow particle size distribution (nPSD); Mass transfer; Eddy dispersion; PRESSURE LIQUID-CHROMATOGRAPHY; TOTAL PORE BLOCKING; B-TERM EXPRESSIONS; LONGITUDINAL DIFFUSION; TEMPERATURE-GRADIENTS; SHELL PARTICLES; PERFORMANCE; PACKINGS; EQUATION; IMPACT;
D O I
10.1016/j.chroma.2016.05.037
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Columns packed with new commercially available 1.9 fully porous particles of narrow particle size distribution (nPSD) are characterized by extremely high efficiency. Under typical reversed phase conditions, these columns are able to generate very high number of theoretical plates (in the order of 300,000 plates/m and more). In this paper, we investigate the origin of the high performance of these nPSD columns by performing a series of measurements that include, in addition to the traditional determination of the van Deemter curve, peak parking, pore blocking and inverse size exclusion experiments. Two nPSD columns (both 100 x 3.0 mm) have been considered in this study: the first one, packed with particles of 80 angstrom pore size, is commercially available. The second one is a prototype column packed with 1.9 fully porous particles of 120 angstrom pore size. The main conclusion of our study is that these nPSD columns are characterized by extremely low eddy dispersion, while longitudinal diffusion and mass transfer kinetics are substantially equivalent to those of other fully porous particles of similar chemistry. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:78 / 85
页数:8
相关论文
共 45 条
[1]   Methods for the experimental characterization and analysis of the efficiency and speed of chromatographic columns: A step-by-step tutorial [J].
Andres, Axel ;
Broeckhoven, Ken ;
Desmet, Gert .
ANALYTICA CHIMICA ACTA, 2015, 894 :20-34
[2]   Method transfer from high-pressure liquid chromatography to ultra-high-pressure liquid chromatography. II. Temperature and pressure effects [J].
Asberg, Dennis ;
Samuelsson, Jorgen ;
Lesko, Marek ;
Cavazzini, Alberto ;
Kaczmarski, Krzysztof ;
Fornstedt, Torgny .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1401 :52-59
[3]   Random-close packing limits for monodisperse and polydisperse hard spheres [J].
Baranau, Vasili ;
Tallarek, Ulrich .
SOFT MATTER, 2014, 10 (21) :3826-3841
[4]   Tortuosity of porous particles [J].
Barrande, M. ;
Bouchet, R. ;
Denoyel, R. .
ANALYTICAL CHEMISTRY, 2007, 79 (23) :9115-9121
[5]   Errors involved in the existing B-term expressions for the longitudinal diffusion in fully porous chromatographic media - Part II: Experimental data in packed columns and surface diffusion measurements [J].
Broeckhoven, K. ;
Cabooter, D. ;
Lynen, F. ;
Sandra, P. ;
Desmet, G. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1188 (02) :189-198
[6]   Morphology and Separation Efficiency of Low-Aspect-Ratio Capillary Ultrahigh Pressure Liquid Chromatography Columns [J].
Bruns, Stefan ;
Grinias, James P. ;
Blue, Laura E. ;
Jorgenson, James W. ;
Tallarek, Ulrich .
ANALYTICAL CHEMISTRY, 2012, 84 (10) :4496-4503
[7]   Physical reconstruction of packed beds and their morphological analysis: Core-shell packings as an example [J].
Bruns, Stefan ;
Tallarek, Ulrich .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (14) :1849-1860
[8]   Confocal Laser Scanning Microscopy Method for Quantitative Characterization of Silica Monolith Morphology [J].
Bruns, Stefan ;
Muellner, Tibor ;
Kollmann, Martin ;
Schachtner, Joachim ;
Hoeltzel, Alexandra ;
Tallarek, Ulrich .
ANALYTICAL CHEMISTRY, 2010, 82 (15) :6569-6575
[9]   Relationship between the particle size distribution of commercial fully porous and superficially porous high-performance liquid chromatography column packings and their chromatographic performance [J].
Cabooter, D. ;
Fanigliulo, A. ;
Bellazzi, G. ;
Allieri, B. ;
Rottigni, A. ;
Desmet, G. .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (45) :7074-7081
[10]   Total pore blocking as an alternative method for the on-column determination of the external porosity of packed and monolithic reversed-phase columns [J].
Cabooter, Deirdre ;
Lynen, Frederic ;
Sandra, Pat ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1157 (1-2) :131-141