Ion detection with photonic crystal microcavities

被引:40
作者
Chakravarty, S [1 ]
Topol'ancik, J
Bhattacharya, P
Chakrabarti, S
Kang, Y
Meyerhoff, ME
机构
[1] Univ Michigan, Dept Elect Engn & Comp Sci, Solid State Elect Lab, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
关键词
D O I
10.1364/OL.30.002578
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We have experimentally demonstrated a cation and anion sensor by using short linear photonic crystal microcavities with an embedded quantum dot active region. The photonic crystal microcavity covered with an ion-selective polymer forms a submicrometer optical detection system sensitive to small changes of perchlorate anion (ClO4-) and calcium cation (Ca2+) concentrations. (c) 2005 Optical Society of America.
引用
收藏
页码:2578 / 2580
页数:3
相关论文
共 15 条
  • [1] Fine-tuned high-Q photonic-crystal nanocavity
    Akahane, Y
    Asano, T
    Song, BS
    Noda, S
    [J]. OPTICS EXPRESS, 2005, 13 (04) : 1202 - 1214
  • [2] High-Q photonic nanocavity in a two-dimensional photonic crystal
    Akahane, Y
    Asano, T
    Song, BS
    Noda, S
    [J]. NATURE, 2003, 425 (6961) : 944 - 947
  • [3] Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors
    Buhlmann, P
    Pretsch, E
    Bakker, E
    [J]. CHEMICAL REVIEWS, 1998, 98 (04) : 1593 - 1687
  • [4] Ultracompact biochemical sensor built with two-dimensional photonic crystal microcavity
    Chow, E
    Grot, A
    Mirkarimi, LW
    Sigalas, M
    Girolami, G
    [J]. OPTICS LETTERS, 2004, 29 (10) : 1093 - 1095
  • [5] Development of multianalyte sensor arrays composed of chemically derivatized polymeric microspheres localized in micromachined cavities
    Goodey, A
    Lavigne, JJ
    Savoy, SM
    Rodriguez, MD
    Curey, T
    Tsao, A
    Simmons, G
    Wright, J
    Yoo, SJ
    Sohn, Y
    Anslyn, EV
    Shear, JB
    Neikirk, DP
    McDevitt, JT
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (11) : 2559 - 2570
  • [6] Photonic crystal chemical sensors: pH and ionic strength
    Lee, K
    Asher, SA
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2000, 122 (39) : 9534 - 9537
  • [7] Dual-sorption model of water uptake in poly(vinyl chloride)-based ion-selective membranes: Experimental water concentration and transport parameters
    Li, Z
    Li, XZ
    Petrovic, S
    Harrison, DJ
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (10) : 1717 - 1725
  • [8] Photonic crystal laser sources for chemical detection
    Loncar, M
    Scherer, A
    Qiu, YM
    [J]. APPLIED PHYSICS LETTERS, 2003, 82 (26) : 4648 - 4650
  • [9] Peper S., 2003, SENS UPDATE, V13, P83, DOI [10.10 02/seup.200390014, DOI 10.1002/SEUP.200390014]
  • [10] IMMOBILIZATION OF COMPONENTS IN POLYMER MEMBRANE-BASED CALCIUM-SELECTIVE BULK OPTODES
    ROSATZIN, T
    HOLY, P
    SEILER, K
    RUSTERHOLZ, B
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (18) : 2029 - 2035