New Approach for Near-Real-Time Measurement of Elemental Composition of Aerosol Using Laser-Induced Breakdown Spectroscopy

被引:47
作者
Diwakar, Prasoon [1 ]
Kulkarni, Pramod [1 ]
Birch, M. Eileen [1 ]
机构
[1] Ctr Dis Control & Prevent, NIOSH, Cincinnati, OH 45226 USA
关键词
INDUCED PLASMA SPECTROSCOPY; ELECTROSTATIC PRECIPITATOR; CULTURAL-HERITAGE; METAL AEROSOLS; TOXIC METALS; TRACE-METALS; DUST LAYERS; PARTICLES; AIR; SINGLE;
D O I
10.1080/02786826.2011.625059
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A new approach has been developed for making near-real-time measurement of elemental composition of aerosols using plasma spectroscopy. The method allows preconcentration of miniscule particle mass (pg to ng) directly from the sampled aerosol stream through electrostatic deposition of charged particles (30-900 nm) onto a flat-tip microneedle electrode. The collected material is subsequently ablated from the electrode and monitored by laser-induced breakdown spectroscopy. Atomic emission spectra were collected using a broadband spectrometer with a wavelength range of 200-980 nm. A single-sensor delay time of 1.3 mu s was used in the spectrometer for all elements to allow simultaneous measurement of multiple elements. The system was calibrated for various elements including Cd, Cr, Cu, Mn, Na, and Ti. The absolute mass detection limits for these elements were experimentally determined and found to be in the range of 0.018-5 ng. The electrostatic collection technique has many advantages over other substrate-based methods involving aerosol collection on a filter or its focused deposition using an aerodynamic lens. Because the particle mass is collected over a very small area that is smaller than the spatial extent of the laser-induced plasma, the entire mass is available for analysis. This considerably improves reliability of the calibration and enhances measurement accuracy and precision. Further, the aerosol collection technique involves very low pressure drop, thereby allowing higher sample flow rates with much smaller pumps-a desirable feature for portable instrumentation. Higher flow rates also make it feasible to measure trace element concentrations at part per trillion levels. Detection limits in the range of 18-670 ng m(-3) can be achieved for most of the elements studied at a flow rate of 1.5 L min(-1) with sampling times of 5 min.
引用
收藏
页码:316 / 332
页数:17
相关论文
共 74 条
[11]   Chemical and microphysical characterization of ambient aerosols with the aerodyne aerosol mass spectrometer [J].
Canagaratna, M. R. ;
Jayne, J. T. ;
Jimenez, J. L. ;
Allan, J. D. ;
Alfarra, M. R. ;
Zhang, Q. ;
Onasch, T. B. ;
Drewnick, F. ;
Coe, H. ;
Middlebrook, A. ;
Delia, A. ;
Williams, L. R. ;
Trimborn, A. M. ;
Northway, M. J. ;
DeCarlo, P. F. ;
Kolb, C. E. ;
Davidovits, P. ;
Worsnop, D. R. .
MASS SPECTROMETRY REVIEWS, 2007, 26 (02) :185-222
[12]   Comparison of nonintensified and intensified CCD detectors for laser-induced breakdown spectroscopy [J].
Carranza, JE ;
Gibb, E ;
Smith, BW ;
Hahn, DW ;
Winefordner, JD .
APPLIED OPTICS, 2003, 42 (30) :6016-6021
[13]   Sampling statistics and considerations for single-shot analysis using laser-induced breakdown spectroscopy [J].
Carranza, JE ;
Hahn, DW .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (04) :779-790
[14]   On-line analysis of ambient air aerosols using laser-induced breakdown spectroscopy [J].
Carranza, JE ;
Fisher, BT ;
Yoder, GD ;
Hahn, DW .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (06) :851-864
[15]   TIME-RESOLVED LIBS EXPERIMENT FOR QUANTITATIVE-DETERMINATION OF POLLUTANT CONCENTRATIONS IN AIR [J].
CASINI, M ;
HARITH, MA ;
PALLESCHI, V ;
SALVETTI, A ;
SINGH, DP ;
VASELLI, M .
LASER AND PARTICLE BEAMS, 1991, 9 (02) :633-639
[16]   Variables influencing the precision of laser-induced breakdown spectroscopy measurements [J].
Castle, BC ;
Talabardon, K ;
Smith, BW ;
Winefordner, JD .
APPLIED SPECTROSCOPY, 1998, 52 (05) :649-657
[17]   Field measurement comparison of aerosol metals using aerosol beam focused laser-induced plasma spectrometer and reference methods [J].
Cheng, MD .
TALANTA, 2003, 61 (02) :127-137
[18]   Real-time measurement of trace metals on fine particles by laser-induced plasma techniques [J].
Cheng, MD .
FUEL PROCESSING TECHNOLOGY, 2000, 65 (65) :219-229
[19]   Analysis of material collected on swipes using laser-induced breakdown spectroscopy [J].
Chinni, Rosemarie ;
Cremers, David A. ;
Multari, Rosalie .
APPLIED OPTICS, 2010, 49 (13) :C143-C152
[20]   DIRECT DETECTION OF BERYLLIUM ON FILTERS USING THE LASER SPARK [J].
CREMERS, DA ;
RADZIEMSKI, LJ .
APPLIED SPECTROSCOPY, 1985, 39 (01) :57-63