Comparison of self-refraction using a simple device, USee, with manifest refraction in adults

被引:3
|
作者
Annadanam, Anvesh [1 ]
Varadaraj, Varshini [1 ]
Mudie, Lucy I. [1 ]
Liu, Alice [1 ]
Plum, William G. [1 ]
White, J. Kevin [2 ]
Collins, Megan E. [1 ]
Friedman, David S. [1 ]
机构
[1] Johns Hopkins Sch Med, Wilmer Eye Inst, Dana Ctr Prevent Ophthalmol, Baltimore, MD 21205 USA
[2] Global Vis 2020, Easton, MD USA
来源
PLOS ONE | 2018年 / 13卷 / 02期
关键词
VISION IMPAIRMENT; EYE HEALTH; ERROR; SPECTACLES; INDIA; POPULATION; PREVALENCE; BLINDNESS;
D O I
10.1371/journal.pone.0192055
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background The USee device is a new self-refraction tool that allows users to determine their own refractive error. We evaluated the ease of use of USee in adults, and compared the refractive error correction achieved with USee to clinical manifest refraction. Methods Sixty adults with uncorrected visual acuity <20/30 and spherical equivalent between -6.00 and +6.00 diopters completed manifest refraction and self-refraction. Results Subjects had a mean (+/- SD) age of 53.1 (+/- 18.6) years, and 27 (45.0%) were male. Mean (+/- SD) spherical equivalent measured by manifest refraction and self-refraction were -0.90 D (+/- 2.53) and +/- 1.22 diopters (+/- 2.42), respectively (p = 0.001). The proportion of subjects correctable to >= 20/30 in the better eye was higher for manifest refraction (96.7%) than self-refraction (83.3%, p = 0.005). Failure to achieve visual acuity >= 20/30 with self-refraction in right eyes was associated with increasing age (per year, OR: 1.05; 95% CI: 1.00-1.10) and higher cylindrical power (per diopter, OR: 7.26; 95% CI: 1.88-28.1). Subjectively, 95% of participants thought USee was easy to use, 85% thought self-refraction correction was better than being uncorrected, 57% thought vision with self-refraction correction was similar to their current corrective lenses, and 53% rated their vision as "very good" or "excellent" with self-refraction. Conclusion Self-refraction provides acceptable refractive error correction in the majority of adults. Programs targeting resource-poor settings could potentially use USee to provide easy on-site refractive error correction.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Self-refraction using a simple device reliably predicts manifest refraction
    Annadanam, Anvesh
    Varadaraj, Varshini
    Mudie, Lucy
    Liu, Alice
    Plum, William G.
    White, Kevin
    Collins, Megan E.
    Friedman, David S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [2] Comparison of self-refraction using EyeQue Insight and EyeQue Personal Vision Tracker (PVT) with manifest refraction in adult Ghanaian Sample
    Boakye, Elizabeth Ewurabena
    Andoh, Albert Kwadwo Amoah
    Duah, Isaiah Junior Osei
    Artes, Paul H.
    Acquah, Eldrick Adu
    Eisenbarth, Werner
    Ben Kumah, David
    Arhin, Joycelyn Arko
    Addo, Emmanuel Kofi
    Akuffo, Kwadwo Owusu
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [3] INSTABILITY AND SELF-REFRACTION OF SOLITONS
    OSTROVSKY, LA
    SHRIRA, VI
    ZHURNAL EKSPERIMENTALNOI I TEORETICHESKOI FIZIKI, 1976, 71 (10): : 1412 - 1420
  • [4] Comparison of Manifest Refraction and Cycloplegic Refraction Using Retinoscopy or an Autorefractor in Children
    Park, Aram
    Chung, Seung Ah
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (08): : 1274 - 1281
  • [5] Comparison of Automated Self-Refraction Using NETRA with Table-Mounted Autorefractor and Subjective Refraction in an Academic Optometry Clinic
    Li, Zhongqiu
    Leibold, Collin McCloskey
    Binder, Steven W.
    Beyer, Jill
    Warner, Katherine A.
    Chang, Robert
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [6] SELF-REFRACTION OF WEAK SHOCK-WAVES
    FRIDMAN, VE
    SOVIET PHYSICS ACOUSTICS-USSR, 1982, 28 (04): : 323 - 328
  • [7] SELF-REFRACTION OF SMALL AMPLITUDE SHOCK-WAVES
    FRIDMAN, VE
    WAVE MOTION, 1982, 4 (02) : 151 - 161
  • [8] Vision correction in the remote North of Ghana using the self-refraction Adspec (TM)
    Carlson, A. S.
    AFRICAN VISION AND EYE HEALTH JOURNAL, 2006, 65 (01): : 41 - 46
  • [9] A method for patient self-refraction and on-site eyeglass assembly
    Weinkle, Jennie
    Pole, Cameron
    Thomas, Benjamin
    Schiffman, Joyce
    Shi, Wei
    Lee, Richard K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [10] Self-refraction Accuracy with Adjustable Spectacles among Children in Ghana
    Ilechie, Alex Azuka
    Abokyi, Samuel
    Owusu-Ansah, Andrew
    Boadi-Kusi, Samuel Bert
    Denkyira, Andrew Kofi
    Abraham, Carl Halladay