Estimation of Spatial Scale across the Visual Field Using Sinusoidal Stimuli

被引:18
作者
Keltgen, Kelsey M. [1 ]
Swanson, William H. [1 ]
机构
[1] Indiana Univ, Sch Optometry, Bloomington, IN USA
关键词
CONTRAST DETECTION THRESHOLDS; SINE WAVE PATTERNS; CORTICAL REPRESENTATION; ECCENTRICITY; 0-DEGREES; GANGLION-CELLS; NEURAL LOSSES; PERIMETRY; SENSITIVITY; GLAUCOMA; VARIABILITY;
D O I
10.1167/iovs.10-6674
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To characterize contrast sensitivity for sinusoidal stimuli across the central visual field and help bridge the gap between perimetry and visual psychophysics by developing a contrast-sensitivity template for spatial scale (experiment 1) and testing it on a new dataset (experiment 2). METHODS. In experiment 1, 40 subjects free of eye disease, ages 43 to 84 years, had one eye tested. Twenty-three locations along the horizontal and vertical meridians were tested with sinusoidal stimuli having peak spatial frequencies of 0.5, 1.0, and 2.0 cpd and a spatial bandwidth of 1.0 octave. Contrast sensitivity functions were fit with a low-pass template slid horizontally on a log-log plot by a spatial scale factor. In experiment 2, 29 of the original subjects had one eye tested. Twenty-six locations in grid form were tested with sinusoidal stimuli having peak spatial frequencies of 0.375, 0.53, 0.75, and 1.5 cpd. Spatial scale values were predicted using the 0.375 cpd data and template and compared to empirical values determined from the remaining data. RESULTS. In experiment 1, the change in spatial scale alone fit the mean sensitivities well (residual sum of squares = 0.01 log unit). Spatial scale increased with eccentricity except for horizontal nasal displacements between 3 and 15. In experiment 2, differences between empirical and predicted spatial scale values were within +/-0.1 log unit (mean and SEM: 0.00 +/- 0.01 log unit). CONCLUSIONS. Spatial scale characterized the visual field tested in perimetry well and can contribute to further linkage between clinical perimetry and basic vision science. (Invest Ophthalmol Vis Sci. 2012;53:633-639) DOI:10.1167/iovs.10-6674
引用
收藏
页码:633 / 639
页数:7
相关论文
共 34 条
  • [11] Graham N., 1992, Current Directions in Psychological Science, V1, P55
  • [12] GRATING AND FLICKER SENSITIVITY IN THE NEAR AND FAR PERIPHERY - NASO-TEMPORAL ASYMMETRIES AND BINOCULAR SUMMATION
    GRIGSBY, SS
    TSOU, BH
    [J]. VISION RESEARCH, 1994, 34 (21) : 2841 - 2848
  • [13] Neural losses correlated with visual losses in clinical perimetry
    Harwerth, RS
    Carter-Dawson, L
    Smith, EL
    Barnes, G
    Holt, WF
    Crawford, MLJ
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (09) : 3152 - 3160
  • [14] Visual field defects and neural losses from experimental glaucoma
    Harwerth, RS
    Crawford, MLJ
    Frishman, LJ
    Viswanathan, S
    Smith, EL
    Carter-Dawson, L
    [J]. PROGRESS IN RETINAL AND EYE RESEARCH, 2002, 21 (01) : 91 - 125
  • [15] AUTOMATIC PERIMETER FOR GLAUCOMA VISUAL-FIELD SCREENING AND CONTROL - CONSTRUCTION AND CLINICAL CASES
    HEIJL, A
    KRAKAU, CET
    [J]. ALBRECHT VON GRAEFES ARCHIV FUR KLINISCHE UND EXPERIMENTELLE OPHTHALMOLOGIE, 1975, 197 (01): : 13 - 23
  • [16] HEIJL A, 1987, ARCH OPHTHALMOL-CHIC, V105, P1544
  • [17] Henson DB, 2000, INVEST OPHTH VIS SCI, V41, P417
  • [18] Development and evaluation of a contrast sensitivity perimetry test for patients with glaucoma
    Hot, Aliya
    Dul, Mitchell W.
    Swanson, William H.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (07) : 3049 - 3057
  • [19] Kerrigan-Baumrind LA, 2000, INVEST OPHTH VIS SCI, V41, P741
  • [20] PERIMETRY OF CONTRAST DETECTION THRESHOLDS OF MOVING SPATIAL SINE WAVE PATTERNS .2. FAR PERIPHERAL VISUAL-FIELD (ECCENTRICITY 0-DEGREES TO 50-DEGREES)
    KOENDERINK, JJ
    BOUMAN, MA
    BUENODEMESQUITA, AE
    SLAPPENDEL, S
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1978, 68 (06) : 850 - 854