Estimation of Spatial Scale across the Visual Field Using Sinusoidal Stimuli

被引:18
作者
Keltgen, Kelsey M. [1 ]
Swanson, William H. [1 ]
机构
[1] Indiana Univ, Sch Optometry, Bloomington, IN USA
关键词
CONTRAST DETECTION THRESHOLDS; SINE WAVE PATTERNS; CORTICAL REPRESENTATION; ECCENTRICITY; 0-DEGREES; GANGLION-CELLS; NEURAL LOSSES; PERIMETRY; SENSITIVITY; GLAUCOMA; VARIABILITY;
D O I
10.1167/iovs.10-6674
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To characterize contrast sensitivity for sinusoidal stimuli across the central visual field and help bridge the gap between perimetry and visual psychophysics by developing a contrast-sensitivity template for spatial scale (experiment 1) and testing it on a new dataset (experiment 2). METHODS. In experiment 1, 40 subjects free of eye disease, ages 43 to 84 years, had one eye tested. Twenty-three locations along the horizontal and vertical meridians were tested with sinusoidal stimuli having peak spatial frequencies of 0.5, 1.0, and 2.0 cpd and a spatial bandwidth of 1.0 octave. Contrast sensitivity functions were fit with a low-pass template slid horizontally on a log-log plot by a spatial scale factor. In experiment 2, 29 of the original subjects had one eye tested. Twenty-six locations in grid form were tested with sinusoidal stimuli having peak spatial frequencies of 0.375, 0.53, 0.75, and 1.5 cpd. Spatial scale values were predicted using the 0.375 cpd data and template and compared to empirical values determined from the remaining data. RESULTS. In experiment 1, the change in spatial scale alone fit the mean sensitivities well (residual sum of squares = 0.01 log unit). Spatial scale increased with eccentricity except for horizontal nasal displacements between 3 and 15. In experiment 2, differences between empirical and predicted spatial scale values were within +/-0.1 log unit (mean and SEM: 0.00 +/- 0.01 log unit). CONCLUSIONS. Spatial scale characterized the visual field tested in perimetry well and can contribute to further linkage between clinical perimetry and basic vision science. (Invest Ophthalmol Vis Sci. 2012;53:633-639) DOI:10.1167/iovs.10-6674
引用
收藏
页码:633 / 639
页数:7
相关论文
共 34 条
  • [1] Characteristics of the normative database for the Humphrey Matrix perimeter
    Anderson, AJ
    Johnson, CA
    Fingeret, M
    Keltner, JL
    Spry, PGD
    Wall, M
    Werner, JS
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (04) : 1540 - 1548
  • [2] Anderson D.R., 1999, Automated static perimetry, V2nd
  • [3] PSYCHOPHYSICAL LOCALIZATION OF THE HUMAN VISUAL STREAK
    ANDERSON, RS
    WILKINSON, MO
    THIBOS, LN
    [J]. OPTOMETRY AND VISION SCIENCE, 1992, 69 (03) : 171 - 174
  • [4] HUMAN PERIPHERAL SPATIAL-RESOLUTION FOR ACHROMATIC AND CHROMATIC STIMULI - LIMITS IMPOSED BY OPTICAL AND RETINAL FACTORS
    ANDERSON, SJ
    MULLEN, KT
    HESS, RF
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1991, 442 : 47 - 64
  • [5] [Anonymous], 1946, J I ELECT ENG, DOI DOI 10.1049/JI-1.1947.0015
  • [6] BodisWollner I, 1997, CLIN NEUROSCI, V4, P284
  • [7] RETINAL GANGLION-CELLS IN ALZHEIMERS-DISEASE AND AGING
    CURCIO, CA
    DRUCKER, DN
    [J]. ANNALS OF NEUROLOGY, 1993, 33 (03) : 248 - 257
  • [8] Ganglion Cell Loss and Dysfunction: Relationship to Perimetric Sensitivity
    Drasdo, Neville
    Mortlock, Katharine E.
    North, Rachel V.
    [J]. OPTOMETRY AND VISION SCIENCE, 2008, 85 (11) : 1036 - 1042
  • [9] Garway-Heath DF, 2000, INVEST OPHTH VIS SCI, V41, P1774
  • [10] Fundamentals of exact perimetry (Reprinted from Ophthalmologica vol 109, pg 57-70, 1945)
    Goldmann, H
    [J]. OPTOMETRY AND VISION SCIENCE, 1999, 76 (08) : 599 - 604