Optimizing reverse shoulder arthroplasty component position in the setting of advanced arthritis with posterior glenoid erosion: a computer-enhanced range of motion analysis
被引:67
作者:
Keener, Jay D.
[1
]
Patterson, Brendan M.
[1
]
Orvets, Nathan
[1
]
Aleem, Alexander W.
[1
]
Chamberlain, Aaron M.
[1
]
机构:
[1] Washington Univ, Dept Orthopaed Surg, CB 8233,660 S Euclid Ave, St Louis, MO 63110 USA
关键词:
Reverse shoulder arthroplasty;
glenoid deformity;
glenohumeral arthritis;
range of motion;
lateralized glenoid;
B2;
glenoid;
PRIMARY GLENOHUMERAL OSTEOARTHRITIS;
NECK-SHAFT ANGLE;
DESIGN;
IMPINGEMENT;
LATERALIZATION;
PROSTHESIS;
RETROVERSION;
MORPHOLOGY;
ABDUCTION;
HIERARCHY;
D O I:
10.1016/j.jse.2017.09.011
中图分类号:
R826.8 [整形外科学];
R782.2 [口腔颌面部整形外科学];
R726.2 [小儿整形外科学];
R62 [整形外科学(修复外科学)];
学科分类号:
摘要:
Background: Our study purpose was to determine the optimal glenoid and humeral reverse shoulder arthroplasty (RSA) component design and position in osteoarthritic shoulders with severe glenoid retroversion deformities. Methods: Computed tomography scans from 10 subjects were analyzed with advanced software including RSA range of motion (ROM) analysis. Variables included glenoid component retroversion of 0 degrees, 5 degrees, 10 degrees, 15 degrees, and 20 degrees and baseplate lateralization of 0, 5, and 10 mm. Humeral variables included 135 degrees, 145 degrees, and 155 degrees angle of inclination (AOI) combined with variable humeral offset. Results: Glenoid component lateralization had the greatest influence on ROM. In comparing each ROM direction among all lateralization options independently, there were significantly greater adduction, abduction, external rotation, extension, and flexion motions with progressively greater lateralization. Internal rotation motion was greater at 10 mm only. In analyzing the effects of glenoid version independently, no differences in adduction or abduction ROM were seen. With greater retroversion, decreased external rotation and extension motion was noted; however, greater internal rotation and flexion motion was seen with the exception of flexion at 10 mm of lateralization. For adduction, external rotation, and extension, a more valgus AOI resulted in less ROM at each progressively greater AOI independent of humeral lateralization. Internal rotation and flexion motions were greater with a more varus AOI but not significant between each inclination angle. Abduction ROM was maximized with a more valgus AOI. Humeral lateralization had no effect on ROM. Conclusions: In the setting of RSA for advanced glenoid osteoarthritic deformities, optimal ROM is achieved with 10-mm baseplate lateralization and neutral to 5 degrees of retroversion mated to a humeral implant with a varus (135 degrees) inclination angle. (C) 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.