Amplitude Behavior of AO Mode Transduced Using Circumferentially Misaligned Air-Coupled Transducers

被引:0
|
作者
Chennamsetti, R. [1 ]
Khan, I. [1 ]
机构
[1] DRDO, R&D E E, Composites Res Ctr, Pune 411015, Maharashtra, India
关键词
Lamb Wave; Air-Coupled Probe; Misalignment; Orthotropic Plate; Isotropic Plate; LAMB WAVES;
D O I
10.1007/s40799-016-0121-x
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Air-coupled transducers are successfully employed for selective excitation and reception of Lamb waves in both orthotropic and isotropic plates. While using air-coupled transducers for Lamb wave applications, the transducers are to be set at (1) proper orientation and also (2) they have to satisfy the "co-planarity condition.'' Fulfilling these two conditions will result in transmission and reception of high amplitude Lamb wave in the plate. In the present work, one of the misalignments, termed "circumferential misalignment,'' is introduced between the air-coupled transmitter and receiver in such a way that the coplanarity condition is violated. In the misaligned configuration, the fundamental antisymmetric Lamb mode (A(o)) was transmitted and received. Interestingly, it was found from experiments that, with the increase in severity of the misalignment, amplitude of the A(o) mode decreases, and the normalized amplitude of the A(o) mode follow the double and the single Gaussian curves in the orthotropic and isotropic plates, respectively.
引用
收藏
页码:1221 / 1226
页数:6
相关论文
共 50 条
  • [11] Damage Assessment in Composite Material Using Air-Coupled Transducers
    Mindykowski, Damian
    Wandowski, Tomasz
    Kudela, Pawel
    Fiborek, Piotr
    Radzienski, Maciej
    EUROPEAN WORKSHOP ON STRUCTURAL HEALTH MONITORING (EWSHM 2022), VOL 3, 2023, : 13 - 23
  • [12] Air-coupled nondestructive evaluation using micromachined ultrasonic transducers
    Hansen, ST
    Mossawir, BJ
    Ergun, AS
    Degertekin, FL
    Khuri-Yakub, BT
    1999 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 1999, : 1037 - 1040
  • [13] Air-Coupled Flexural Electrodynamic Acoustic Transducers
    Eriksson, T. J. R.
    Laws, M.
    Dixon, S. M.
    Ramadas, S. N.
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 1021 - 1024
  • [14] Focusing of Ferroelectret Air-Coupled Ultrasound Transducers
    Gaal, Mate
    Bartusch, Juergen
    Dohse, Elmar
    Schadow, Florian
    Koeppe, Enrico
    42ND ANNUAL REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION: INCORPORATING THE 6TH EUROPEAN-AMERICAN WORKSHOP ON RELIABILITY OF NDE, 2016, 1706
  • [15] Air-coupled ultrasonic capacitance transducers for NDT
    Hutchins, DA
    Bashford, AG
    Wright, WMD
    Schindel, DW
    Kumar, A
    TRENDS IN NDE SCIENCE AND TECHNOLOGY - PROCEEDINGS OF THE 14TH WORLD CONFERENCE ON NDT (14TH WCNDT), VOLS 1-5, 1996, : 2061 - 2064
  • [16] Effect of misalignment of air-coupled probes on Ao Lamb mode propagating in a metal plate
    Ramadas, C.
    Hood, Avinash
    Khan, Irfan
    Balasubramaniam, Krishnan
    ULTRASONICS, 2014, 54 (05) : 1401 - 1408
  • [17] ULTRASONIC MEASUREMENTS IN POLYMERIC MATERIALS USING AIR-COUPLED CAPACITANCE TRANSDUCERS
    HUTCHINS, DA
    WRIGHT, WMD
    SCHINDEL, DW
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1994, 96 (03): : 1634 - 1642
  • [18] Metal Cap Flexural Transducers for Air-Coupled Ultrasonics
    Eriksson, T. J. R.
    Dixon, S.
    Ramadas, S. N.
    41ST ANNUAL REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOL 34, 2015, 1650 : 1287 - 1291
  • [19] Development of air-coupled ultrasound transducers for nondestructive evaluation
    Wang, Xuefeng
    Fan, Ying
    Tian, Wei-Cheng
    Kwon, Hyon-Jin
    Kennerly, Stacey
    Claydon, Glenn
    May, Andrew
    MEMS 2008: 21ST IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2008, : 932 - +
  • [20] Air-coupled ultrasonic transducers for the detection of defects in plates
    Castaings, M
    Cawley, P
    Farlow, R
    Hayward, G
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 15A AND 15B, 1996, 15 : 1083 - 1090