Determination of psilocin and psilocybin using flow injection analysis with acidic potassium permanganate and tris(2,2′-bipyridyl) ruthenium(II) chemiluminescence detection respectively

被引:19
作者
Anastos, N
Barnett, NW
Lewis, SW [1 ]
Gathergood, N
Scammells, PJ
Sims, DN
机构
[1] Deakin Univ, Sch Biol & Chem Sci, Geelong, Vic 3217, Australia
[2] Monash Univ, Victorian Coll Pharm, Parkville, Vic 3052, Australia
[3] Forens Sci SA, Adelaide, SA 5000, Australia
关键词
psilocin; psilocybin; flow injection analysis; chemiluminescence; synthesis; forensic analysis;
D O I
10.1016/j.talanta.2004.11.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, rapid and sensitive method for the determination of psilocin and psilocybin is described. This is the first report on the determination of psilocin and psilocybin using flow injection analysis with acidic potassium permanganate and tris(2,2'-bipyridyl)ruthenium(II) chemiluminescence. The limits of detection (signal-to-noise ratio = 3) are 9 x 10(-10) M and 3 x 10(-10) M for psilocin and psilocybin, respectively. A concise synthetic route for psilocin in three steps from readily available starting materials is also described. The structures were elucidated on the basis of spectroscopic data. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:354 / 359
页数:6
相关论文
共 50 条
  • [21] Flow-Injection Chemiluminescence Determination of Moxifloxacin Using Tris(2,2-bipyridyl) Ruthenium(II)-Ce(IV) System
    Lee, Sang Hak
    Kim, Go Eun
    Alam, Seikh Mafiz
    Kang, Meea
    Choi, Jong Ha
    Ferdous, Taslima
    Suh, Yeoun Suk
    SENSOR LETTERS, 2011, 9 (01) : 247 - 251
  • [22] Chemiluminescence detection of amino acids and related compounds using acidic potassium permanganate, manganese(IV) or tris(2,2′-bipyridine)ruthenium(III)
    Terry, Jessica M.
    Smith, Zoe M.
    McDermott, Geoffrey P.
    Waite, Rebecca J.
    Barnett, Neil W.
    Henderson, Luke C.
    Altimari, Jarrad M.
    Francis, Paul S.
    TALANTA, 2012, 99 : 1051 - 1056
  • [23] Determination of glyphosate and related compounds using HPLC with tris(2,2'-bipyridyl)ruthenium(II) electrogenerated chemiluminescence detection
    Ridlen, JS
    Klopf, GJ
    Nieman, TA
    ANALYTICA CHIMICA ACTA, 1997, 341 (2-3) : 195 - 204
  • [24] Coreactants of tris(2,2′-bipyridyl)ruthenium(II) Electrogenerated Chemiluminescence
    Yuan, Yali
    Han, Shuang
    Hu, Lianzhe
    Parveen, Saima
    Xu, Guobao
    ELECTROCHIMICA ACTA, 2012, 82 : 484 - 492
  • [25] Flow Injection Determination of Moxifloxacin using Silver Nanoparticles with Tris(2,2-Bipyridyl)Ruthenium(III)-Ce(IV) Chemiluminescence Detection
    Wabaidur, S. M.
    Alam, S. M.
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2017, 79 (03) : 402 - 410
  • [26] Flow-injection chemiluminescence determination of aspartic acid in tea leaves using tris (2,2′-bipyridyl) ruthenium (II)-Ce(IV) system
    Lee, Sang Hak
    Jeon, Chi Wan
    Wabaidur, Saikh Mohammad
    JOURNAL OF FLUORESCENCE, 2008, 18 (3-4) : 655 - 660
  • [27] Flow-Injection Chemiluminescence Determination of Aspartic Acid in Tea Leaves Using Tris (2,2′-bipyridyl) Ruthenium (II)–Ce(IV) System
    Sang Hak Lee
    Chi Wan Jeon
    Saikh Mohammad Wabaidur
    Journal of Fluorescence, 2008, 18 : 655 - 660
  • [28] Pulse injection analysis with chemiluminescence detection:: determination of citric acid using tris-(2,2′-bipyridine) ruthenium(II)
    He, Z
    Gao, H
    Yuan, LJ
    Lu, SF
    Meng, H
    Li, XY
    Zeng, Y
    TALANTA, 1998, 47 (02) : 301 - 304
  • [29] Flow-injection determination of vitamin A in pharmaceutical formulations using Tris(2,2′-bipyridyl)Ru(II)-Ce(IV) chemiluminescence detection
    Yaqoob, Mohammad
    Waseem, Amir
    Rishi, Lubna
    Nabi, Abdul
    LUMINESCENCE, 2009, 24 (05) : 276 - 281
  • [30] Chemiluminescence determination of thiourea using tris(2,2′-bipyridyl)ruthenium(II)-KMnO4 system
    He, ZK
    Wu, FW
    Meng, H
    Ling, LS
    Yuan, LJ
    Luo, QY
    Zeng, YE
    ANALYTICAL SCIENCES, 1999, 15 (04) : 381 - 383