Building three-dimensional images using a time-reversal chaotic cavity

被引:52
作者
Montaldo, G [1 ]
Palacio, D [1 ]
Tanter, M [1 ]
Fink, M [1 ]
机构
[1] Lab Ondes & Acoust, F-75005 Paris, France
关键词
D O I
10.1109/TUFFC.2005.1516021
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The design of two-dimensional (2-D) arrays for three-dimensional (3-D) ultrasonic imaging is a major challenge in medical and nondestructive applications. Thousands of transducers are typically needed for focusing and steering in a 3-D volume. In this article, we propose a different concept allowing us to obtain electronic 3-D focusing with a small number of transducers. The basic idea is to couple a small number of transducers to a chaotic reverberating cavity with one face in contact with the body of the patient. The reverberations of the ultrasonic waves inside the cavity create at each reflection virtual transducers. The cavity acts as an ultrasonic kaleidoscope multiplying the small number of transducers and creating a much larger virtual transducer array. By exploiting time-reversal processing, it is possible to use collectively all the virtual transducers to focus a pulse everywhere in a 3-D volume. The reception process is based on a nonlinear pulse-inversion technique in order to ensure a good contrast. The feasibility of this concept for the building of 3-D images was demonstrated using a prototype relying only on 31 emission transducers and a single reception transducer.
引用
收藏
页码:1489 / 1497
页数:9
相关论文
共 22 条
  • [1] Measurements of harmonic generation in a focused finite-amplitude sound beam
    Averkiou, MA
    Hamilton, MF
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 98 (06) : 3439 - 3442
  • [2] DEVELOPMENT OF AN ULTRASONIC SYSTEM FOR 3-DIMENSIONAL RECONSTRUCTION OF THE FETUS
    BABA, K
    SATOH, K
    SAKAMOTO, S
    OKAI, T
    ISHII, S
    [J]. JOURNAL OF PERINATAL MEDICINE, 1989, 17 (01) : 19 - 24
  • [3] Burns PN, 1996, CLIN RADIOL, V51, P50
  • [4] CHANG PH, 1995, IEEE T ULTRASON FERR, V42, P1020
  • [5] Experimental investigation of finite amplitude distortion-based, second harmonic pulse echo ultrasonic imaging
    Christopher, T
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (01) : 158 - 162
  • [6] 2-DIMENSIONAL RANDOM ARRAYS FOR REAL-TIME VOLUMETRIC IMAGING
    DAVIDSEN, RE
    JENSEN, JA
    SMITH, SW
    [J]. ULTRASONIC IMAGING, 1994, 16 (03) : 143 - 163
  • [7] Ultrasonic pulse compression with one-bit time reversal through multiple scattering
    Derode, A
    Tourin, A
    Fink, M
    [J]. JOURNAL OF APPLIED PHYSICS, 1999, 85 (09) : 6343 - 6352
  • [8] Taking advantage of multiple scattering to communicate with time-reversal antennas
    Derode, A
    Tourin, A
    de Rosny, J
    Tanter, M
    Yon, S
    Fink, M
    [J]. PHYSICAL REVIEW LETTERS, 2003, 90 (01) : 014301/1 - 014301/4
  • [9] One-channel time reversal of elastic waves in a chaotic 2D-silicon cavity
    Draeger, C
    Fink, M
    [J]. PHYSICAL REVIEW LETTERS, 1997, 79 (03) : 407 - 410
  • [10] One-channel time-reversal in chaotic cavities: Experimental results
    Draeger, C
    Aime, JC
    Fink, M
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 105 (02) : 618 - 625