Low Diopter Phakic Implantable Collamer Lens: Refractive and Visual Outcomes in Low Myopia and Myopic Astigmatism

被引:7
作者
Alonso-Juarez, Ernesto [1 ]
Velazquez-Villoria, Daniel [2 ,3 ]
机构
[1] INSADOF Clin, Calle Doctrinos 4,1, Salamanca 37002, Spain
[2] Villoria Clin, Vigo, Spain
[3] Villoria Clin, Pontevedra, Spain
来源
CLINICAL OPHTHALMOLOGY | 2022年 / 16卷
关键词
low myopia; phakic intraocular low power lens; refractive surgery; QUALITY-OF-LIFE; IN-SITU KERATOMILEUSIS; LOW-TO-MODERATE; INTRAOCULAR-LENS; CENTRAL HOLE; ICL;
D O I
10.2147/OPTH.S373378
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Nowadays the Implantable Collamer Lens (ICL - STAAR Surgical. Monrovia. CA) is a refractive surgical technique offered not only when laser corneal correction is not possible but also when the patient requires premium quality indexes and when dry eye is a concern. The use of ICL phakic lenses in low myopic patients is an emanate factor to study and analyze in order to determine treatment predictability and stability in such patients. In this paper, we conducted a 1-year follow-up study on patients with myopia below -3.5D implanted with ICL lenses. Methods: This was a retrospective analytical study that includes patients with phakic ICL implantation from 2 independent clinics with a minimum follow-up of 12 months. Visual acuity, refractive outcomes, vault, and intraocular pressure (IOP) were assessed at 1, 6 and 12 months. Results: Eighty-two eyes from 82 patients were included in this analysis. Mean spherical equivalent was -2.34 +/- 0.82 (Range -5.50 to -1.00 D). Mean spherical implanted ICL power was -3.04 +/- 0.78 D. In 25 eyes (30.5%) a Toric-ICL (TICL) was implanted with a mean TICL cylinder power of +1.64 +/- 0.64. Efficacy and security index remained stable for 12 months at 1.07 and 1.09, respectively. Mean vault at 12 months was 513.78 +/- 262.87 mu m and IOP was 15.63 +/- 2.17 mmHg. Conclusion: Phakic Implantable Collamer Lens implantation in very low myopia is a predictable, stable, safe, and effective technique with high efficacy and security indexes. Low diopter Toric ICL is also an excellent option for refractive surgery in cases of low diopter astigmatism.
引用
收藏
页码:2969 / 2977
页数:9
相关论文
共 36 条
[1]   Photorefractive keratectomy (PRK) versus laser-assisted in-situ keratomileusis (LASIK) for myopia [J].
AJ, Shortt ;
BDS, Allan .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2006, (02)
[2]   Induced Higher-order aberrations after Laser In Situ Keratomileusis (LASIK) Performed with Wavefront-Guided IntraLase Femtosecond Laser in moderate to high Astigmatism [J].
Al-Zeraid, Ferial M. ;
Osuagwu, Uchechukwu L. .
BMC OPHTHALMOLOGY, 2016, 16
[3]   Five-Year Follow-up of Correction of Myopia: Posterior Chamber Phakic Intraocular Lens With a Central Port Design [J].
Alfonso, Jose F. ;
Fernandez-Vega-Cueto, Luis ;
Alfonso-Bartolozzi, Belen ;
Montes-Mico, Robert ;
Fernandez-Vega, Luis .
JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (03) :169-+
[4]   Clinical outcomes after implantation of a posterior chamber collagen copolymer phakic intraocular lens with a central hole for myopic correction [J].
Alfonso, Jose F. ;
Lisa, Carlos ;
Fernandez-Vega Cueto, Luis ;
Belda-Salmeron, Lurdes ;
Madrid-Costa, David ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (06) :915-921
[5]   Long-term evaluation of the central vault after phakic CollamerA® lens (ICL) implantation using OCT [J].
Alfonso, Jose F. ;
Fernandez-Vega, L. ;
Lisa, C. ;
Fernandes, P. ;
Gonzalez-Meijome, J. ;
Montes-Mico, R. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (12) :1807-1812
[6]   Astigmatism correction with toric implantable collamer lens in low and high astigmatism groups [J].
Cano-Ortiz, Antonio ;
Sanchez-Ventosa, Alvaro ;
Membrillo, Alberto ;
Castillo, Rosa ;
Gomera, Aurora ;
Lopez-Perez, Maria Dolores ;
Villarrubia, Alberto .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (01) :183-192
[7]   Ten-year clinical outcomes after implantation of a posterior chamber phakic intraocular lens for myopia [J].
Choi, Jae Hwan ;
Lim, Dong Hui ;
Nam, Seung Wan ;
Yang, Chan Min ;
Chung, Eui Sang ;
Chung, Tae-Young .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (11) :1555-1561
[8]   Refractive Errors & Refractive Surgery Preferred Practice Pattern® [J].
Chuck, Roy S. ;
Jacobs, Deborah S. ;
Lee, Jimmy K. ;
Afshari, Natalie A. ;
Vitale, Susan ;
Shen, Tueng T. ;
Keenan, Jeremy D. .
OPHTHALMOLOGY, 2018, 125 (01) :P1-P104
[9]  
Dougherty PJ, 2017, CLIN OPHTHALMOL, V11, P273, DOI 10.2147/OPTH.S120427
[10]   Seven-year follow-up of posterior chamber phakic intraocular lens with central port design [J].
Fernandez-Vega-Cueto, Luis ;
Alfonso-Bartolozzi, Belen ;
Lisa, Carlos ;
Madrid-Costa, David ;
Alfonso, Jose F. .
EYE AND VISION, 2021, 8 (01)