Computed tomography characteristics of the aortic valve and the geometry of SAPIEN 3 transcatheter heart valve in patients with bicuspid aortic valve disease

被引:54
作者
Kawamori, Hiroyuki [1 ]
Yoon, Sung-Han [1 ]
Chakravarty, Tarun [1 ]
Maeno, Yoshio [1 ]
Kashif, Mohammad [1 ]
Israr, Sharjeel [1 ]
Abramowitz, Yigal [1 ]
Mangat, Geeteshwar [1 ]
Miyasaka, Masaki [1 ]
Rami, Tanya [1 ]
Kazuno, Yoshio [1 ]
Takahashi, Nobuyuki [1 ]
Jilaihawi, Hasan [1 ]
Nakamura, Mamoo [1 ]
Cheng, Wen [1 ]
Friedman, John [1 ]
Berman, Daniel [1 ]
Sharma, Rahul [1 ]
Makkar, Raj R. [1 ]
机构
[1] Cedars Sinai Med Ctr, Inst Heart, 127 S San Vincente Blvd, Los Angeles, CA 90048 USA
关键词
transcatheter aortic valve implantation; bicuspid aortic valve; computed tomography; SAPIEN; 3; IMPLANTATION; REPLACEMENT; PREDICTORS; STENOSIS; AREA;
D O I
10.1093/ehjci/jex333
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims We assessed the geometry of transcatheter heart valve (THV) and valve function associated with SAPIEN 3 implantation in patients with bicuspid aortic valve (BAV) stenosis. Methods and results We included 280 consecutive patients who had a contrast computed tomography (CT) before and after transcatheter aortic valve implantation (TAVI) in our institution. Each THV was assessed by CT at five cross-sectional levels: inflow, annulus, mid, sinus, and outflow. The geometry of THV was assessed for eccentricity (1 - minimum diameter/maximum diameter) and expansion (CT derived external valve area/nominal external valve area). CT measurements and transthoracic echocardiogram data were compared between BAV and tricuspid aortic valve (TAV). Among 280 patients, 41 patients were diagnosed as BAV. Compared to TAV, BAV was associated with lower expansion at mid-level, sinus-level, and outflow-level (mid 94.1 +/- 6.8% vs. 98.1 +/- 7.8%; P = 0.002, sinus 95.9 +/- 7.2% vs. 101.6 +/- 8.5%; P < 0.001, outflow 107.6 +/- 6.2% vs. 109.9 +/- 6.6%; P = 0.043), and higher eccentricity at all levels [inflow 3.5% (1.9-5.3) vs. 6.0% (3.2-7.5); P < 0.001, annulus 3.1% (1.6-5.2) vs. 5.4% (3.1-7.8); P = 0.002, mid 3.0% (1.4-4.9) vs. 6.0% (3.3-10.4); P < 0.001, sinus 3.0% (1.7-5.1) vs. 7.6% (4.0-11.4); P < 0.001, and outflow 2.5% (1.3-4.3) vs. 4.9% (2.2-7.5); P < 0.001]. There were no differences in frequency of paravalvular leak >= moderate and mean post-procedural gradient between BAV and TAV. Conclusion BAV patients have greater THV eccentricity at all levels and lower THV expansion at mid, sinus, and outflow levels than the TAV patients. There were no differences in parameters of valve function between BAV and TAV patients. Despite the observed geometrical differences, TAVI with SAPIEN 3 in BAV patients allows for feasible valve function.
引用
收藏
页码:1408 / 1418
页数:11
相关论文
共 19 条
[1]   Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function [J].
Delgado, Victoria ;
Ng, Arnold C. T. ;
van de Veire, Nico R. ;
van der Kley, Frank ;
Schuijf, Joanne D. ;
Tops, Laurens F. ;
de Weger, Arend ;
Tavilla, Giuseppe ;
de Roos, Albert ;
Kroft, Lucia J. ;
Schalij, Martin J. ;
Bax, Jeroen J. .
EUROPEAN HEART JOURNAL, 2010, 31 (09) :1114-1123
[2]   Predictors of permanent pacemaker requirement after transcatheter aortic valve implantation: Insights from a Brazilian Registry [J].
Gensas, Caroline S. ;
Caixeta, Adriano ;
Siqueira, Dimytri ;
Carvalho, Luiz A. ;
Sarmento-Leite, Rogerio ;
Mangione, Jose A. ;
Lemos, Pedro A. ;
Colafranceschi, Alexandre S. ;
Caramori, Paulo ;
Ferreira, Maria Cristina ;
Abizaid, Alexandre ;
Brito, Fabio S., Jr. .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 175 (02) :248-252
[3]   Transcatheter Aortic Valve Implantation for Patients With Severe Bicuspid Aortic Valve Stenosis [J].
Hayashida, Kentaro ;
Bouvier, Erik ;
Lefevre, Thierry ;
Chevalier, Bernard ;
Hovasse, Thomas ;
Romano, Mauro ;
Garot, Philippe ;
Watanabe, Yusuke ;
Farge, Arnaud ;
Donzeau-Gouge, Patrick ;
Cormier, Bertrand ;
Morice, Marie-Claude .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (03) :284-291
[4]   A revised methodology for aortic-valvar complex calcium quantification for transcatheter aortic valve implantation [J].
Jilaihawi, Hasan ;
Makkar, Raj R. ;
Kashif, Mohammad ;
Okuyama, Kazuaki ;
Chakravarty, Tarun ;
Shiota, Takahiro ;
Friede, Gerald ;
Nakamura, Mamoo ;
Doctor, Niraj ;
Rafique, Asim ;
Shibayama, Kentaro ;
Mihara, Hirotsugu ;
Trento, Alfredo ;
Cheng, Wen ;
Friedman, John ;
Berman, Daniel ;
Fontana, Gregory P. .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (12) :1324-1332
[5]  
Kappetein AP, 2012, J AM COLL CARDIOL, V60, P1438, DOI [10.1016/j.jacc.2012.09.001, 10.1093/ejcts/ezs533]
[6]   Comparison of SAPIEN 3 and SAPIEN XT transcatheter heart valve stent-frame expansion: evaluation using multi-slice computed tomography [J].
Kazuno, Yoshio ;
Maeno, Yoshio ;
Kawamori, Hiroyuki ;
Takahashi, Nobuyuki ;
Abramowitz, Yigal ;
Babak, Hariri ;
Kashif, Mohammad ;
Chakravarty, Tarun ;
Nakamura, Mamoo ;
Cheng, Wen ;
Friedman, John ;
Berman, Daniel ;
Makkar, Raj R. ;
Jilaihawi, Hasan .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2016, 17 (09) :1054-1062
[7]   Multidetector Computed Tomography in Transcatheter Aortic Valve Implantation [J].
Leipsic, Jonathon ;
Gurvitch, Ronen ;
LaBounty, Troy M. ;
Min, James K. ;
Wood, David ;
Johnson, Mark ;
Ajlan, Amr M. ;
Wijesinghe, Namal ;
Webb, John G. .
JACC-CARDIOVASCULAR IMAGING, 2011, 4 (04) :416-429
[8]   Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery. [J].
Leon, Martin B. ;
Smith, Craig R. ;
Mack, Michael ;
Miller, D. Craig ;
Moses, Jeffrey W. ;
Svensson, Lars G. ;
Tuzcu, E. Murat ;
Webb, John G. ;
Fontana, Gregory P. ;
Makkar, Raj R. ;
Brown, David L. ;
Block, Peter C. ;
Guyton, Robert A. ;
Pichard, Augusto D. ;
Bavaria, Joseph E. ;
Herrmann, Howard C. ;
Douglas, Pamela S. ;
Petersen, John L. ;
Akin, Jodi J. ;
Anderson, William N. ;
Wang, Duolao ;
Pocock, Stuart .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (17) :1597-1607
[9]   Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Disease [J].
Mylotte, Darren ;
Lefevre, Thierry ;
Sondergaard, Lars ;
Watanabe, Yusuke ;
Modine, Thomas ;
Dvir, Danny ;
Bosmans, Johan ;
Tchetche, Didier ;
Kornowski, Ran ;
Sinning, Jan-Malte ;
Theriault-Lauzier, Pascal ;
O'Sullivan, Crochan J. ;
Barbanti, Marco ;
Debry, Nicolas ;
Buithieu, Jean ;
Codner, Pablo ;
Dorfmeister, Magdalena ;
Martucci, Giuseppe ;
Nickenig, Georg ;
Wenaweser, Peter ;
Tamburino, Corrado ;
Grube, Eberhard ;
Webb, John G. ;
Windecker, Stephan ;
Lange, Ruediger ;
Piazza, Nicolo .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (22) :2330-2339
[10]   DETERMINATION OF THE STENOTIC AORTIC-VALVE AREA IN ADULTS USING DOPPLER ECHOCARDIOGRAPHY [J].
OTTO, CM ;
PEARLMAN, AS ;
COMESS, KA ;
REAMER, RP ;
JANKO, CL ;
HUNTSMAN, LL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (03) :509-517