Simplifying Size-Specific Radiation Dose Estimates in Pediatric CT

被引:45
作者
Khawaja, Ranish Deedar Ali [1 ]
Singh, Sarabjeet [1 ]
Vettiyil, Beth [1 ]
Lim, Ruth [2 ]
Gee, Michael [1 ]
Westra, Sjirk [2 ]
Kalra, Mannudeep K. [1 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Radiol,Div Pediat Imaging, Boston, MA 02114 USA
关键词
body diameter; body weight; pediatric CT; size-specific dose estimate; COMPUTED-TOMOGRAPHY; PROTOCOLS; INDEX;
D O I
10.2214/AJR.13.12191
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Size-specific dose estimates (SSDEs) require manual measurement of torso diameters for individual patients-anteroposterior (hereafter, D-AP), lateral (hereafter, D-LAT), and effective (hereafter, D-E)-which can be tedious in clinical settings. We aimed to determine whether body weight can be used as a surrogate for measuring diameter in children. MATERIALS AND METHODS. D-AP and D-LAT were measured in 522 consecutive CT examinations (chest, 187 and abdomen-pelvis, 335) performed in 483 (+/- SD) children (13 +/- 7 years). Effective diameter (D-E1) was calculated as the square root of the product of D-AP and D-LAT. A second measurement of effective diameter (D-E2) was obtained using automated software. Correlation coefficients between patient body weight, age, and diameter were measured in addition to 95% prediction interval analysis for diameters corresponding to body weight. RESULTS. Median body weight was 51 kg, and mean D-AP, D-LAT, D-E1, and D-E2 were 207.1 +/- 50.8 mm, 289.8 +/- 72.6 mm, 243.3 +/- 62.0 mm, and 233.6 +/- 55.4 mm, respectively. Overall body weight had a strong correlation with diameter (0.88, 0.85, 0.86, and 0.93 respectively; all p < 0.0001). SSDE measured using body weight was statistically not different than SSDE measured using effective diameters (p = 0.9). Children weighing less than 27 kg and between 46 and 100 kg had statistically significant correlations with torso diameters, whereas only anteroposterior and effective diameters were correlated with children weighing between 27 and 45 kg. Children less than 4 years old had strong correlation with all diameters. Adolescents (15-18 years) did not have statistically significant correlation with any of the diameters. CONCLUSION. Body weight, instead of body diameter, can be used as a surrogate to estimate size-specific dose in children, making dose estimation clinically simpler and more rapid.
引用
收藏
页码:167 / 176
页数:10
相关论文
共 50 条
[21]   CNN application for automated determination of the patient's size to obtain the size-specific dose estimated in CT [J].
Hernandez-Davila, Erik R. ;
Torres-Garcia, Eugenio ;
Aranda-Lara, Liliana ;
Roldan-Valadez, Ernesto ;
Isaac-Olive, Keila ;
Flores-Reyes, Mario .
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (03)
[22]   Size-Specific Dose Estimate and Effective Dose for Pediatric Computed Tomography [J].
Khan, Rukhsar ;
Shah, Mudasir Ashraf ;
Wahab, Shagufta ;
Khan, Rizwan Ahmad .
JOURNAL OF MEDICAL PHYSICS, 2025, 50 (01) :173-183
[23]   How to Appropriately Calculate Effective Dose for CT Using Either Size-Specific Dose Estimates or Dose-Length Product [J].
Brady, Samuel L. ;
Mirro, Amy E. ;
Moore, Bria M. ;
Kaufman, Robert A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (05) :953-958
[24]   Size-Specific Dose Estimate (SSDE) Provides a Simple Method to Calculate Organ Dose for Pediatric CT Examinations [J].
Moore, B. ;
Brady, S. ;
Mirro, A. ;
Kaufman, R. .
MEDICAL PHYSICS, 2014, 41 (06) :424-+
[25]   Multi-slice CT examinations of adult patients at Sudanese hospitals: radiation exposure based on size-specific dose estimates (SSDE) [J].
Einas H. Bashier ;
I. I. Suliman .
La radiologia medica, 2018, 123 :424-431
[26]   Size-specific dose estimates for various weighting factors of CTDI equation [J].
Tomonobu Haba ;
Masanao Kobayashi ;
Shuji Koyama .
Physical and Engineering Sciences in Medicine, 2020, 43 :155-162
[27]   A Segmentation-based Automated Calculation of Patient Size and Size-specific Dose Estimates in Pediatric Computed Tomography Scans [J].
Abdulkadir, Muhammad Kabir ;
Osman, Noor Diyana ;
Achuthan, Anusha ;
Nasirudin, Radin A. ;
Ahmad, Muhammad Zabidi ;
Zain, Noor Hasyima Mat ;
Shuaib, Ibrahim Lutfi .
JOURNAL OF MEDICAL PHYSICS, 2024, 49 (03) :456-463
[28]   Development of size-specific dose estimates for common computed tomography examinations: a study in Ghana [J].
Ohene-Botwe, Benard ;
Anim-Sampong, Samuel ;
Nkansah, Josephine .
JOURNAL OF RADIOLOGICAL PROTECTION, 2023, 43 (01)
[29]   SIZE-specific dose estimate for lower-limb CT [J].
Kobayashi, Masanao ;
Nishihara, Yusei ;
Haba, Tomonobu ;
Matsunaga, Yuta ;
Asada, Yasuki ;
Kobayashi, Shigeki .
PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2022, 45 (04) :1183-1191
[30]   THE SIZE-SPECIFIC DOSE ESTIMATE OF PAEDIATRIC HEAD CT EXAMINATIONS FOR VARIOUS PROTOCOLS [J].
Fahmi, Arif ;
Anam, Choirul ;
Ali, Mohd Hanafi .
RADIATION PROTECTION DOSIMETRY, 2020, 188 (04) :522-528