The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis

被引:15
|
作者
Yang, Xiang [1 ]
Zhao, Yang [1 ]
Zhong, Yu [1 ,2 ]
Duan, Xuanchu [1 ,2 ]
机构
[1] Changsha Aier Eye Hosp, Changsha, Hunan, Peoples R China
[2] Cent South Univ, Aier Sch Ophthalmol, Changsha, Hunan, Peoples R China
关键词
Minimally invasive glaucoma surgery; XEN; Meta-analysis; OPEN-ANGLE GLAUCOMA; AB INTERNO; INTRAOCULAR-PRESSURE; SUCCESS RATES; SURGERY; OUTCOMES; SAFETY; CONJUNCTIVA; QUALITY; EYES;
D O I
10.1186/s12886-022-02502-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Xen is a device for minimally invasive glaucoma surgery, and is used to treat POAG, pseudoexfoliative or pigmentary glaucoma, as well as refractory glaucoma. The efficacy of XEN in treating glaucoma remains to be confirmed and clarified. Hence, we conducted a systematic review and meta-analysis to examine the efficacy and associated complication of XEN implantations. Methods We conducted a literature search in PubMed, EMBASE, the Cochrane Library of Systematic Reviews, Web of Science, China National Knowledge Infrastructure, WanFang and SinoMed databases to identify studies, published before May 15, 2021, which evaluated XEN in glaucoma, and parameters for measurements included intra-ocular pressure (IOP), number of anti-glaucoma medications (NOAM), and bleb needling rate. We compared the measurements of XEN-only procedure between phaco-XEN and trabeculectomy, and we also did sub-analysis based on time points, glaucoma types, ethnics, etc. Sensitivity analyses and publication bias were conducted for evaluating bias.This study followed the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA 2020) reporting guideline. Results We identified 78 eligible studies, analysis revealed obvious IOP reduction after XEN stent implantation (SMD: 1.69, 95% CI 1.52 to 1.86, p value < 0.001) and NOAM reduction (SMD: 2.11, 95% CI 1.84 to 2.38, p value < 0.001). Sub-analysis showed no significant difference with respect to time points, ethnicities, and economic status. No significant difference was found between XEN treatment effect on POAG and PEXG eyes and between pseudo-phakic and phakic eyes. Also no significant difference was found between XEN and phaco-XEN surgery in terms of IOP after surgery (SMD: -0.01, 95% CI -0.09 to 0.08, p value 0.894). However, NOAM (after publication bias correction) and bleb needling rate (RR: 1.45, 95% CI 1.06to 1.99, p value 0.019) were lower in phaco-XEN group compared to XEN only group. Compared to trabeculectomy, XEN implantation had similar after-surgery IOP, however bleb needling rate (RR: 2.42, 95% CI 1.33 to 4.43, p value 0.004) was higher. Conclusion Our results confirmed that XEN is effective in lowering both IOP and NOAM till 48 months after surgery. It is noteworthy that XEN implantation leads to higher needling rate, compared to phaco-XEN or trabeculectomy. Further research, studying complications of XEN on non-European ethnicities, especially on Asian, are in urgent need before XEN is widely applied.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Efficacy of postoperative management with 5-fluorouracil injections after XEN Gel Stent implantation
    Walek, Ewa
    Przeidziecka-Dolyk, Joanna
    Helemejko, Iwona
    Misiuk-Hojlo, Marta
    INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (01) : 235 - 246
  • [32] XEN45 Gel Stent implantation in eyes with primary open angle glaucoma: A study from a single hospital in Taiwan
    Chao, Yu-Jang
    Ko, Yu-Chieh
    Chen, Mei-Ju
    Lo, Kang-Jung
    Chang, Yu-Fan
    Liu, Catherine Jui-Ling
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2021, 84 (01) : 108 - 113
  • [33] Two-year outcomes of minimally invasive XEN Gel Stent implantation in primary open-angle and pseudoexfoliation glaucoma
    Rauchegger, Teresa
    Angermann, Reinhard
    Willeit, Peter
    Schmid, Eduard
    Teuchner, Barbara
    ACTA OPHTHALMOLOGICA, 2021, 99 (04) : 369 - 375
  • [34] Two-Year Results of XEN Gel Stent Implantation for Pseudoexfoliative Glaucoma in Phakic versus Pseudophakic Eyes
    Nasyrov, Emil
    Merle, David A.
    Gassel, Caroline J.
    Wenzel, Daniel A.
    Voykov, Bogomil
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (14)
  • [35] Cholesterol and glaucoma: a systematic review and meta-analysis
    Posch-Pertl, Laura
    Michelitsch, Monja
    Wagner, Gernot
    Wildner, Brigitte
    Silbernagel, Guenther
    Pregartner, Gudrun
    Wedrich, Andreas
    ACTA OPHTHALMOLOGICA, 2022, 100 (02) : 148 - 158
  • [36] Bilateral XEN Gel Stent Implantation in Juvenile-Onset Open-Angle Glaucoma
    Klug, Emma
    Sola-Del Valle, David
    CASE REPORTS IN OPHTHALMOLOGY, 2020, 11 (02): : 336 - 341
  • [37] Efficacy and safety data for the Ab interno XEN45 gel stent implant at 3 Years: A retrospective analysis
    Gabbay, Itay E.
    Goldberg, Mordechai
    Allen, Felicity
    Lin, Zhiheng
    Morley, Christine
    Pearsall, Tahmina
    Muraleedharan, Veena
    Ruben, Simon
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (02) : 1016 - 1022
  • [38] XEN Gel Stent in the management of primary open-angle glaucoma
    Post, Michal
    Lubinski, Wojciech
    Sliwiak, Dominik
    Podboruczynska-Jodko, Karolina
    Mularczyk, Maciej
    DOCUMENTA OPHTHALMOLOGICA, 2020, 141 (01) : 65 - 76
  • [39] Clinical Outcomes of Ahmed Glaucoma Valve Implantation With or Without Intravitreal Bevacizumab Pretreatment for Neovascular Glaucoma: A Systematic Review and Meta-Analysis
    Zhou, Minwen
    Xu, Xun
    Zhang, Xiulan
    Sun, Xiaodong
    JOURNAL OF GLAUCOMA, 2016, 25 (07) : 551 - 557
  • [40] Choroidal Detachment after XEN Gel Stent Implantation
    Cutolo, Carlo Alberto
    Negri, Letizia
    Olivari, Sara
    Cappelli, Francesca
    Traverso, Carlo Enrico
    Iester, Michele
    JOURNAL OF OPHTHALMOLOGY, 2021, 2021