Visualization of wrist ligaments with 3D and 2D magnetic resonance imaging at 3 Tesla

被引:6
|
作者
Gotestrand, Simon [1 ,2 ]
Bjorkman, Anders [3 ,4 ]
Bjorkman-Burtscher, Isabella M. [5 ,6 ]
Ab-Fawaz, Rana [7 ,8 ]
Kristiansson, Ingvar [1 ]
Lundin, Bjorn [1 ,2 ]
Geijer, Mats [5 ,6 ,9 ]
机构
[1] Skane Univ Hosp, Dept Med Imaging & Physiol, Lund, Sweden
[2] Lund Univ, Dept Radiol, Clin Sci, Lund, Sweden
[3] Skane Univ Hosp, Dept Translat Med Hand Surg, Malmo, Sweden
[4] Lund Univ, Wallenberg Ctr Mol Med, Lund, Sweden
[5] Univ Gothenburg, Sahlgrenska Acad, Inst Clin Sci, Dept Radiol, Gothenburg, Sweden
[6] Lund Univ, Dept Clin Sci, Lund, Sweden
[7] Kristianstad Hosp, Dept Radiol, Kristianstad, Sweden
[8] European Telemed Clin, Dept Musculoskeletal Radiol, Barcelona, Spain
[9] Sahlgrens Univ Hosp, Dept Radiol, Gothenburg, Region Vastra G, Sweden
关键词
Triangular fibrocartilage complex; scapholunate; lunotriquetral; intrinsic ligaments; magnetic resonance imaging; wrist; MULTIPLE-READER; SCAPHOLUNATE; TEARS; MRI; PERFORMANCE; QUALITY;
D O I
10.1177/0284185121994044
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Wrist ligaments are challenging to visualize using magnetic resonance imaging (MRI). Injuries involving the scapholunate ligament (SLL), the lunotriquetral ligament (LTL), and the triangular fibrocartilage complex (TFCC) are common and difficult to diagnose, often requiring diagnostic arthroscopy. Purpose To compare the visualization of wrist ligaments on a three-dimensional (3D) sequence with two-dimensional (2D) sequences on 3-T MRI. Material and Methods Eighteen healthy volunteers were examined with a 3D SPACE (sampling perfection with application optimized contrasts using different flip angle evolution) sequence and 2D coronal, axial, and sagittal proton density-weighted (PD) sequences. Four musculoskeletal radiologists graded the anatomical visibility of the SLL, LTL, TFCC, and the image quality, using five grades in a visual grading characteristics (VGC) evaluation. After Bonferroni correction, a P value <= 0.005 was considered statistically significant. Results The 3D images were graded significantly better than the 2D images in the visualization of the dorsal and palmar parts of the SLL and the LTL. Regarding the TFCC, the 3D images were graded significantly better for visualization of the foveal attachment. 2D imaging was not found significantly superior to 3D imaging in any aspect. Conclusion The 3D SPACE sequence was scored as superior to the 2D sequences at 3 T in the assessment of the SLL, the LTL, and the foveal attachment of the TFCC. Thus, 3D SPACE can replace 2D PD sequences when these ligaments need to be assessed.
引用
收藏
页码:368 / 375
页数:8
相关论文
共 50 条
  • [1] Comparison of Modern 3D and 2D MR Imaging Sequences of the Wrist at 3 Tesla
    Rehnitz, C.
    Klaan, B.
    von Stillfried, F.
    Amarteifio, E.
    Burkholder, I.
    Kauczor, H. U.
    Weber, M. A.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (08): : 753 - 762
  • [2] 2D and 3D 3-tesla magnetic resonance imaging of the double bundle structure in anterior cruciate ligament anatomy
    Hanno Steckel
    Gianluca Vadala
    Denise Davis
    Freddie H. Fu
    Knee Surgery, Sports Traumatology, Arthroscopy, 2006, 14 : 1151 - 1158
  • [3] 2D and 3D 3-tesla magnetic resonance imaging of the double bundle structure in anterior cruciate ligament anatomy
    Steckel, Hanno
    Vadala, Gianluca
    Davis, Denise
    Fu, Freddie H.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (11) : 1151 - 1158
  • [4] Comparison of 3D Cube FLAIR with 2D FLAIR for Multiple Sclerosis Imaging at 3 Tesla
    Patzig, M.
    Burke, M.
    Brueckmann, H.
    Fesl, G.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (05): : 484 - 488
  • [5] Magnetic resonance imaging of the knee at 3 and 7 Tesla: a comparison using dedicated multi-channel coils and optimised 2D and 3D protocols
    Welsch, Goetz H.
    Juras, Vladimir
    Szomolanyi, Pavol
    Mamisch, Tallal C.
    Baer, Peter
    Kronnerwetter, Claudia
    Blanke, Matthias
    Fujita, Hiroyuki
    Trattnig, Siegfried
    EUROPEAN RADIOLOGY, 2012, 22 (09) : 1852 - 1859
  • [6] Magnetic resonance imaging of the knee at 3 and 7 Tesla: a comparison using dedicated multi-channel coils and optimised 2D and 3D protocols
    Goetz H. Welsch
    Vladimir Juras
    Pavol Szomolanyi
    Tallal C. Mamisch
    Peter Baer
    Claudia Kronnerwetter
    Matthias Blanke
    Hiroyuki Fujita
    Siegfried Trattnig
    European Radiology, 2012, 22 : 1852 - 1859
  • [7] 2D and 3D visualization of ductile fracture
    Weck, Arnaud
    Wilkinson, David S.
    Tocla, Hiroyuki
    Maire, Eric
    ADVANCED ENGINEERING MATERIALS, 2006, 8 (06) : 469 - 472
  • [8] Comparing 2D and 3D Imaging
    Ballantyne, Lauren
    JOURNAL OF VISUAL COMMUNICATION IN MEDICINE, 2011, 34 (03) : 138 - 141
  • [9] Simultaneous magnetic resonance gadolinium-enhanced 2D perfusion and 3D angiographic imaging
    Goldfarb, JW
    Prasad, PV
    Chen, Q
    Edelman, RR
    MAGNETIC RESONANCE IMAGING, 2003, 21 (06) : 585 - 591
  • [10] Craniosynostosis: prenatal diagnosis by 2D/3D ultrasound, magnetic resonance imaging and computed tomography
    Helfer, Talita Micheletti
    Peixoto, Alberto Borges
    Tonni, Gabriele
    Araujo Junior, Edward
    MEDICAL ULTRASONOGRAPHY, 2016, 18 (03) : 378 - 385